DISCRIMINATION MODE OF SEARCH  

 

Discrimination- The ability of the detector to react to certain types of objects while 

ignoring  others.  In  certain  cases  this  is  useful  to  improve  the  comfort  of  the  search. 
Turning  on  or  off  discriminate  is  performed  by  pressing  the  button  [

AM/DISC

].  When 

discrimination  mode  is  enabled  [

D]

,  briefly  pressing  the  [

AM/DISC

]  button  the 

discrimination 

MAP

  will  appear.  This  view  will  give  the  user  a  quick  view  of  what 

discrimination levels have been set. The discrimination card is broken into 18 sectors with 
10 VDI numbers per sector. The exception is VDI n80 to +90 which obviously has 
11 numbers in this sector. Each sector will appear as either a completely filled box, partially 
filled  box  or  completely  empty  box.  A  completely  filled  box  indicates  this  VDI  sector  has 

been  completely included  and  will  not  be  discriminated  out.  A  partially  filled  box  indicates 
some  VDI  numbers  have  been  excluded  and  those  specific  VDI  numbers  will  be 
discriminated. While a completely empty box indicates all VDI numbers in this sector have 
been discriminated out.  

The  specific  type  of  discrimination  response  is  set  by  setting  the  mode 

Visual 

Discrimination

  (p. 

23)

.  On  the  left  side  of  the  screen  is  the  current  mode  of 

discrimination. If the mode visual discrimination is enabled the letter 

V

 will be displayed 

When a target is detected and it is not included in the discrimination  map the target will 
not generate an audio response nor will a hodograph or VDI value be displayed. 

If  Visual  discrimination  is  off  (discriminate  mode  is  enable)  the  letter 

D

  will  be 

present.  In  this  case  a  target  that  is  not  included  in  the  map  will  not  make  an  audio 
response however there will be a hodograph and VDI of the rejected target. 

When discrimination is turned off (

All metal

 mode ) the Letter 

A

 will appear and 

all targets will generate an audio, hodograph and VDI response. 
.  

DISCRIMINATION MAP  

 

The discrimination characteristics are set in the menu 

Discriminate

. To enter this 

menu choose Discriminate from the menu or long press button [

AM/DISC

] From the 

discriminate menu select the Map parameter by selecting with the cursor and then pressing 

+. The menu will enter options for adjusting the map (a Fig. 

31

).  

 

Map  

 

 
+62  

 

 

 

[ДИСКР]  - The Menu 

 

 

 

Fig. 31  

33 

Содержание Berkut 5

Страница 1: ...1 Berkut 5 VERSION 5 01 DISCRIMINATING METAL DETECTOR OPERATING INSTRUCTIONS...

Страница 2: ...METERS 19 THE SOUND MENU 20 THE DISPLAY MENU 23 THE SEARCH MENU 25 THE DISCRIMINATION MENU 27 THE OTHER MENU 28 THE COIL MENU 30 DYNAMIC AND STATIC OPERATING MODES 31 DISCRIMINATION MODE OF SEARCH 32...

Страница 3: ...ECTOR 40 SOME THOUGHTS ON USING YOUR NEW DETECTOR 42 SCANNING TECHNIQUES 43 ABOUT GROUND BALANCING 43 IDENTIFICATION OF DIFFERENT TYPES OF OBJECTS 44 USE OF THE PINPOINT MODE 45 USING THE EQUALIZER 46...

Страница 4: ...ghters to search for underground utilities pipelines cables manhole wells etc Archaeology and treasure search The device is designed to operate under the following conditions Ambient temperature from...

Страница 5: ...100 Current of the gauge 2 TURBO 220 Current of the gauge 1 27 Current of the gauge 2 TURBO 12 Overall dimensions mm a telescopic bar 1100 1300 X 200 The electronic block 110 X 105 X 68 Weight of the...

Страница 6: ...h metal objects When analyzing the hodographs remember a few general rules Hodographs of small and medium sized ferromagnetic objects are in the left quadrant i e have a negative vector angle Hodograp...

Страница 7: ...e detector from the box When shipped the detector and parts should look like Fig 3 Fig 3 Assemble the Detector For this purpose Remove the detector rod from the box Remove the electronic control box f...

Страница 8: ...lars on the rod as well as the plastic Coil bolt Once assembled your detector should look like Fig 4 Plastic rod The control box Armrest Bar Fig 4 The coil Plastic locking collar THE FRONT PANEL Appea...

Страница 9: ...on In standard search mode increase the value of the last key parameter accessed In menu increases value of current selected parameter In the case of Equalizer will access settings User assigned funct...

Страница 10: ...just turning the detector on and off These other functions can be set in menu Other THE DISPLAY The Berkut 5 LCD display as shown in fig 7 A T S K M An TURBO 003 47 3 sensitivity 15 Fig 7 In normal o...

Страница 11: ...ICE Prior to turning on your detector please read the instructions thoroughly Upon every startup of the detector there is a calibration of the detector in air It is necessary for fine tuning of electr...

Страница 12: ...g there is no presence of large metal objects check to make sure the coil connector is seated correctly and the proper coil is installed If this has been verified and compensation is still not establi...

Страница 13: ...kaline Fig 11 In the inclusion menu following functions are accessible Factory Reset By pressing the button the factory values will be reset Note that parameters of the adjusted coils thus remain a Fi...

Страница 14: ...ent of the coil press the button Battery Selects the type of batteries installed p 29 GROUND BALANCING Proper ground balancing is necessary in order to reduce the effects of ground minerals on the det...

Страница 15: ...the line reaches the display left edge 102 005 AD Fn 180 Fig 16 5 At successful balancing the device will play a melody 6 Press the button GB for transition to standard search mode 7 If ground balance...

Страница 16: ...rox 15 seconds there are no further changes made the key parameter settings will disappear and return to the normal search screen The last adjusted parameter is stored in memory and by pressing the or...

Страница 17: ...nerate an audio response on a detected object Reducing the Audio Threshold setting increases the sensitivity to small and deep targets but also increases the risk of false audio responses The device w...

Страница 18: ...branched menu All parameters are grouped in a separate submenu Access is possible both from the main menu and by means of fast access by long pressing of the corresponding buttons in normal search mo...

Страница 19: ...llowing parameters for adjustment VOLUME 0 10 Sets the overall audio level of the detector EQUALIZER Allows the user to set unique volume levels to 12 different VDI groups The audio level is adjustabl...

Страница 20: ...choose to set the Fe border to a specific negative value to include these small low conductive targets Also one may wish to include some small desirable ferrous objects by adjusting the FE border to e...

Страница 21: ...ould give the greatest variability of frequencies amongst the tones LENGTH FE SHORT NORMS Defines the length of the FE tone NORM under this setting the duration is the same as for non ferrous targets...

Страница 22: ...not all metal A When discrimination is set to on D and visual discrimination is set to on D will now change to a V any target that has been rejected in the discrimination card will not generate a tone...

Страница 23: ...ng weak signals are reduced SEARCH MENU Search Pag1 SFT filter On Big Filter 3 Small Filter 2 Speed AGB 1 Analog Mode Off Ground Comp 3 Fig 23 Search Pag2 Ident Thresh 5 Coil Current 2 Gain 7 Audio Th...

Страница 24: ...racking When enabled the letter T will appear on the left side of the display When disabled the area on the display will be blank While in Autotrack if the device has carried small fine tuning adjustm...

Страница 25: ...ectors set below left border right border TEACH DISCRIMINATE on off Turns on off the fast teach discriminate mode learn accept reject When this mode is set to on while in the normal search mode the bu...

Страница 26: ...ose proximity and frequencies there is an increased risk of interference from each other This can also be the case if you are within close proximity to various sources of EMI To reduce this interferen...

Страница 27: ...nstalled in the detector Options are NIMH or ALKALINE Proper battery type is needed for correct display of battery level in the lcd display PASSAGE MENU On Off When set to off scrolling is restricted...

Страница 28: ...e coil editor parameters To access the editor press button The following options will appear a Fig 29 Currently selected coil ie D6x10 7 On off of including the currently selected in added coils previ...

Страница 29: ...ameter AUTOFINE TUNING on p 18 Pressing the button enters the pinpoint mode in which auto fine tuning is disconnected The lcd display will now display the pinpoint mode screen a Fig 30 TURBO WITH 3 57...

Страница 30: ...cates all VDI numbers in this sector have been discriminated out The specific type of discrimination response is set by setting the mode Visual Discrimination p 23 On the left side of the screen is th...

Страница 31: ...cted group When complete press the Fn button to end the HOLD function Fig 32 Card Hold 62 The Menu Fig 32 For example if you wish to reject VDI numbers 90 to 21 while accepting 20 to 90 perform the fo...

Страница 32: ...e button to accept the object press the button 4 If the received signal level is sufficient the detector will prompt the user either to accept the VDI by pressing To reject or cancel the inclusions pr...

Страница 33: ...ers gain and or coil current p 17 18 or to lift the gauge above over a ground If the overload arises on single instances simply raise the coil and re scan the object There can be situations where an o...

Страница 34: ...s of trash In this program it is important to slow the sweep speed and maintain a constant distance from the ground without deviations Also in this program the coil current is set to TURBO In program...

Страница 35: ...t of the gauge and having addressed in firm AKA service center When bundled with the device the coils used with different frequencies and there are no sensors with the same frequency switching of prof...

Страница 36: ...the headphones is stored separate of the speaker profiles PROGRAM ADJUSTMENT OF COILS Your Berkut 5 is preconfigured to work with the coils manufactured by AKA LLC There are a couple ways to configure...

Страница 37: ...nce procedure on pure ground ferrite or a piece of red brick If the GB value differs from zero significantly then press the button to zero To exit from the adjustment mode press the button GB Switch t...

Страница 38: ...Over a long period of storage batteries can leak and damage your device After each use it is recommended to clean the detector including the coil rods and control box from dirt Immediately after use i...

Страница 39: ...ould include the type of ground as well as temperature It is also important to ground balance on pure soil free of any metals If this is not possible you may excavate approximately 1 5 to 2 Kilo 3 4 l...

Страница 40: ...n appear as a possible coin How can we properly identify these erroneous targets First of all the audio from these large ferrous targets will also sound large and lifting the coil even 40cm off of the...

Страница 41: ...w need to locate its precise location Move the search coil off to one side of the located target along the line A Fig 37 Then activate the pinpoint mode As accurately as possible while maintaining the...

Страница 42: ...In this case you will continuously monitor the situation under the search coil without straining ears EXAMPLES OF SOME VDI A table of VDI values for some objects measured in the air OBJECT Number VDI...

Страница 43: ...ical damages of the electronic block and the device gauge For realisation of guarantee repair it is necessary to show the present maintenance instruction with the specified date of sale In the absence...