THE OTHER MENU
Other
Pag1
Freq offset:
000
Pin-P Automatic:
30
Pin-P Gain:
16
Fn function:
An
PWR function:
Off
Battery:
NiMH
Fig. 26
Other
Pag2
Passage menu:
Off
Cons b-light:
Off
Num Programs: 4
Transmitter Off
Language Eng
Factory Reset
Fig. 27
In menu
OTHER
the following parameters are available:
FREQUENCY OFFSET[0... +250]
Carries out small shifts in the operating
frequency of the metal detector. In cases where two or more detectors,
operating in close proximity and frequencies, there is an increased risk of
interference from each other. This can also be the case if you are within close
proximity to various sources of EMI. To reduce this interference make small
adjustments until satisfactory results are achieved. Whenever changes to the
frequency offset
have been made it is necessary to perform a ground balance
procedure.
NOTE: The best operating characteristics of the detector are at a 0 frequency
offset.
Whenever a coil is changed the frequency offset will automatically be reset to 0.
ATTENTION!
Always perform a ground balance procedure after making ANY
changes to the frequency offset