COMPOINT-LIB manual, Version 1.0
Configuration with TELNET
Configuration of the COMPOINT-LIB
11
Point O, “OUTGOING CALLS“
=========================== OUTGOING CALLS ==================================
SELECTION RANGE: A-J = A
1 = Source Port = 6000
2 = WaitForConnect = N
3 = Send with Length = N
CONNECT TO
4 = Protocol = 1 (ATE0W1S0=0**TEI=1;**DHTC=1;B21)
5 = DialUp = 026245680690139
6 = X.25 Parameter = X026245680690139Ptest
RECONNECT TO
7 = Protocol = 5 (ATE0W1S0=0**HTC=10;B20)
8 = DialUp = 068351029050
9 = X.25 Parameter = X45680690139Ptest
X = Clear Statistic
-----------------------------------------------------------------------------
DialUp Connect ReCon Err Busy NoCarrier NoDialtone NoAnswer Time LastCode
-----------------------------------------------------------------------------
0 0 0 0 0 0 0 0 0
-----------------------------------------------------------------------------
[Q = QUIT] Please enter your choice:
SELECTION RANGE: A-J
By entering A-J you can determine up to 10 outgoing connection
configurations.
Note
: If you want to use 10 parallel connections e.g. X.25 B or D – channel
but if the establishing of the connection will be the same then you will only
need one configuration.
1 = Source Port
= 6000
Here you determine for which TCP/IP Request (PORT) an ISDN dialing will
take place.
2 = WaitForConnect
= N/Y
Here you determine (Y), if first an ISDN connection has to be established in
order to reply to a TCP/Request (SYN).
3 = Send with Length
= (Option)
4 = Protocol
= 1 (ATE0W1S0=0**TEI=1;**DHTC=1;B21)
Here you can select the protocols 1-10
CONNECT TO
(1. dialing)
5 = DialUp
= 026245680690139
Here you enter the ISDN DIALING (phone number)
6 = X.25 Parameter
= X026245680690139Ptest
Here you enter all required X.25—parameter if X.25 had been selected as
protocol
RECONNECT TO
(2. dialing)
7 = Protocol
= 5 (ATE0W1S0=0**HTC=10;B20)
Here you can select the protocols 1-10
8 = DialUp
= 068351029050
Here you enter the ISDN DIALING (phone number)
9 = X.25 Parameter
= X45680690139Ptest
Here you enter all required X.25 – parameter if X.25 had been selected as
protocol
Important:
Please read our manual “handbuch_isdn.pdf.pdf“, for further information