15
COMPOINT-LIB manual, Version 1.0
Configuration with TELNET
Configuration of the COMPOINT-LIB
6
=========================== COM1 MENU =======================================
1 = Destination IP1 = 0.0.0.0
2 = Destination PORT1 = 0
3 = Destination DNS1 =
4 = Destination IP2 = 0.0.0.0
5 = Destination PORT2 = 0
6 = Destination DNS2 =
7 = Connection Setuptime= 20
8 = Connection Time/Dst = 5
9 = InputTimeOut *10ms = 0
a = Baudrate:115 b = Databits:8 c = Parity:N d = Stopbits:1
e = Flow Control:H f = Emulation:NONE g = EmuCode:0000
h = RTS:0 i = DCD:0 j = DTR:0 k = DSR:0
Interface Lines =
+-----------------------------------+
|Name |RTS |CTS |DTR |DSR |DCD |
|Def. |LOW |LOW |LOW |LOW |HIGH |
|Value|LOW |LOW |LOW |LOW |LOW |
+-----------------------------------+
For example:'1=192.168.10.2'
-----------------------------------------------------------------------------
[Q = QUIT] Please enter your choice:
Continue point 2, the “COM1 Menu“
F=Emulation:
The following emulations are available:
Modem- Emulation
Entry:
f=MODEM
PAD-Emulation
Entry: f=PAD
ConnectOnData
Entry:
f=DIRECT
No Emulation
Entry: f=NONE
G=Emucode:
With this menu item you can release customer-specific function.
H=RTS/CTS:
This menu item selects the behaviour of the RTS line (output)
h=0
RTS Allways ON
h=1
RTS Follows CTS
h=2
RTS Follows DSR
h=3
RTS Allways ON
+ Hardware Protocol
h=4
RTS Follows CTS
+ Hardware Protocol
h=5
RTS Follows DSR
+ Hardware Protocol
I=DCD:
This menu item selects the behaviour of the DCD line (output)
i=0
DCD Always ON
i=1
Indicates Connection
i=2
Follows DSR
i=3
Set to input
J=DTR:
This menu item selects the behaviour of the DTR line (output)
j=0
DTR Always ON
j=1
Indicate Connection
j=2
Follows DSR
K=DSR:
This menu item selects the behaviour of the DSR line (input)
k=0
DSR No Control
k=1
DSR Control Incoming
k=2
DSR Clear Connection
Important
:
In the menu “COM1“ only the values a=Baudrate:115(115200Baud)
as well as
e=FlowControl : H(Hardware) are required.