7. Output Т1 is responsible for the ocBridge Plus’s tampers’ state. When the
receiver is installed in the box, tamper buttons are pressed, the output is
permanently closed. When at least one tamper unpressed, the output is opening
and the guard zone sends an alarm signal. It remains in alarm state until both
tamper buttons are in normal state again and the output is closed.
Firmware upgrade
It is possible to upgrade ocBridge Plus’s rmware. Download latest version of
software from the
.
Firmware is upgraded with a help of con guration software. If the ocBridge Plus
is connected to con guration software, you should press “Disconnect” button
without disconnecting the ocBridge Plus itself from PC. Then, in the menu
“Connection”, you should select a COM port where ocBridge Plus is connected.
Then, it is necessary to select “Firmware upgrade” in drop-down menu and then,
pressing the button “Select le”, to show the le path to *.aff le with new
rmware (Picture 26).
Picture 26. Firmware le selection
Then, it is necessary to power the receiver off with switch “10” (Picture 1) and
turn the device on again. After switching on, the upgrade process begins
automatically. In case the process was accomplished successfully, there is a
message “Software upgrade is accomplished” and the receiver is ready for
work.
If there is no message “Software upgrade is accomplished” or there were any
failures during the software upgrade, you should upgrade the software again.
Con guration transfer
It is possible to use the sensors’ con guration transfer to the other device
ocBridge Plus without having to register the sensors again. For the transfer, it is