Picture 20. Alarm zone settings
The alarm zone reacts to bistable detectors (e.g. DoorProtect and LeaksProtect)
with opening/closing, depending on setting “Initial state” (NC/NO). The zone is
in alarm mode until the bistable detectors state returns to its initial state. The
zone reacts to impulse sensors (e.g. MotionProtect, GlassProtect) with
opening/closing depending on setting “Initial state” (NC/NO) with the impulse,
its duration can be adjusted by the setting “Impulse time” (Picture 20). By
default, the “Impulse time” is 1 second, 254 seconds maximum. If alarm is
raised, the zone’s red light “3” is on (Picture 1).
Automation zone can be set as NC or NO (Picture 21). When the “Impulse” way
to react is chosen, the zones reacts to all activations with opening/closing,
depending on “Initial state” setting for the time set in the setting “Impulse time”
— 1 second by default and 254 seconds maximum.
Picture 21. Automation zone settings
When the “Trigger” reaction mode is selected, the zone output changes its initial
state to the opposite one with each new activation signal. The light indicates the
automation zone’s current state – with the activation signal, a red light turns on
or turns off if the normal state is restored. With the “Trigger” reaction mode,
“Impulse time” parameter is unavailable.
Arm/disarm zone is used only for key fobs and keyboards connection (Picture
22).