OM-229 158 Page 24
Mode....: Remote Power..: 0.0 KW
Run Time:>00:03:00 Current: 0 A
Voltage: 0 V
Frequency: 4.5 KHz
Time is the only parameter that can be set. The values are 0
−
99:59:59 or infinity.
6-4-3.
Manual Control
Manual control allows programming of a specific power level for a specific period of time. When this process is selected, the following screen appears
on the display:
Mode....: Manual Power..: 0.0 KW
Command.: 0.0 KW Current: 0 A
Run Time: 00:03:00 Voltage: 0 V
Frequency: 4.5 KHz
The only programmable selections are Command power and Run Time. Command can be adjusted to deliver up to 35 KW (based on maximum
power selected in the set-up screen) for a period of up to 99 hours, 59 minutes, 59 seconds or infinity.
6-4-4.
Auxiliary Relay
The Auxiliary Relay is fully programmable for use in controlling auxiliary equipment such as lamps and solenoids and can operate after the heating cycle
ends. The delay time and on time are set during programming.
Possible selections:
Enable
−
Yes/No
Delay Time
−
00:00:00
−
99:59:59 Or Infinity
On Time
−
00:00:00
−
99:59:59 Or Infinity
Auxiliary Relay
Enable.....: No
Delay Time.: 00:00:00
On Time....: 00:00:00
6-5. Run Status
Run status allows the operator to check status of a program during in-process heating. Depending on the control mode (Timed, Remote, or Manual),
different style screens appear on the display. Run status is for monitoring purposes only and has no selectable or changeable parameters.