Relay operation modes:

Connecting to the hub

Before connecting the device:

Only users with administrator rights can add a device to the app

To pair Relay with a hub:

Bistable — Relay opens or closes contact and remains in this state.

Pulse — Relay opens or closes contacts for a pre-set time (from 0.5 to 255
seconds) then switches back to the initial state.

1. Switch on the hub and check its Internet connection (the logo glows white or

green).

2. Install the 

. Create the account, add the hub to the app, and create at

least one room.

Ajax app

3. Make sure that the hub is not armed, and it does not update by checking its

status in the Ajax app.

4. Connect Relay to 12 or 24 V power supply.

1. Click Add device in the Ajax app.

2. Name the device, scan it, or enter the QR code manually (located on the case

and packaging), select the room.

Содержание Relay

Страница 1: ...e and bistable mode The device communicates with a hub via radio protocol In the line of sight the communication distance is up to 1 000 m Regardless of the type of electrical circuit only a qualified electrician should install Relay The Relay contacts are not galvanically connected to the device itself so they can be connected to the input control circuits of various equipment to imitate a button ...

Страница 2: ... remotely in the Ajax app The Ajax security system can be connected to the central monitoring station of a security company Functional Elements Ajax hubs uartBridge ocBridge Plus automation devices Button How to create and configure a scenario in the Ajax security system Buy low tension relay Relay 1 Antenna 2 Power supply terminal block 3 Contacts terminal block 4 Function button 5 Light indicator...

Страница 3: ... set up Relay Relay features dry potential free contacts The contacts are not connected to the device galvanically so that Relay can imitate a button switch etc in electrical circuits of various voltages sirens electrical valves electromagnetic locks The miniature body makes it possible to install Relay inside a junction box switchboard or a switch Relay closes and opens the contacts by user comma...

Страница 4: ...nds then switches back to the initial state 1 Switch on the hub and check its Internet connection the logo glows white or green 2 Install the Create the account add the hub to the app and create at least one room Ajax app 3 Make sure that the hub is not armed and it does not update by checking its status in the Ajax app 4 Connect Relay to 12 or 24 V power supply 1 Click Add device in the Ajax app ...

Страница 5: ...nds and then retry Relay will appear in the list of hub devices The device statuses update depends on the ping interval set in the hub settings The default value is 36 seconds When switching on for the first time Relay contacts are open When deleting Relay from the system contacts open States Parameter Value Jeweller Signal Strength Signal strength between the hub and Relay 3 Click Add the countdow...

Страница 6: ...active or completely disabled by the user Firmware Device firmware version Device ID Device identifier Settings Settings Value First field Device name can be edited Room Selecting the virtual room to which the device is assigned Relay Mode Choosing the relay operation mode Contact State Normal contact state Pulse duration sec Selecting the pulse duration in the pulse mode From 0 5 to 255 seconds 1 De...

Страница 7: ...d Please note that deactivated device will save it s current state active or inactive Unpair Device Disconnect Relay from a hub and delete its settings Voltage protection the contact will open when the voltage exceeds the limits of 6 5 36 5 V Temperature protection the contact will be opened when the temperature threshold of 85 С inside Relay is reached Indication The Relay light indicator can lig...

Страница 8: ...to 1 000 meters Take this into account when choosing the location for Relay If the device has a low or unstable signal strength use the Installation process When installing Relay in the box lead out the antenna and place it under the plastic frame of the socket The bigger the distance between the antenna and metal structures the lower the risk of interfering and impairment of the radio signal Do n...

Страница 9: ...vice life of the relay 200 000 switchings Supply voltage range 7 24 V DC only Voltage protection Yes min 6 5 V max 36 5 V Maximum load current 5 A at 36 V DC 13 A at 230 V AC Operating modes Pulse and bistable Pulse duration 0 5 to 255 seconds Maximum current protection No Parameter control Yes voltage Device energy consumption Less than 1 W Frequency band 868 0 868 6 MHz or 868 7 869 2 MHz depend...

Страница 10: ...re range From 0 С to 64 С ambient Max temperature protection Yes over 65 C at the place of installation or over 85 C inside the Relay Operating humidity Up to 75 Dimensions 39 33 18 mm Weight 25 g If using inductive or capacitive load the maximum commutated current decreases to 3 A at 24 V DC and to 8 A at 230 V AC Complete Set Warranty Warranty for the AJAX SYSTEMS MANUFACTURING LIMITED LIABILITY...