AJA R20CE Скачать руководство пользователя страница 8

 

8

 

Installation 

 

Typically, R20CE installation consists of the following:

 

1.

 

disconnect power from the frame (remove line cord)

 

2.

 

remove the FR1/FR2 front panel

 

3.

 

install R20CE card module

 

4.

 

apply external color black reference at the frame’s External Reference BNC

 

5.

 

apply power to the frame by connecting a north american-style power cord from the 
frame to mains power (90 to 260 VAC)

Instructions for removing the frame front door for module installation is discussed in the 

 

FR1/FR2 User Manual.

 

External 
Reference 
Information

 

The R20CE expects the External Reference to be an NTSC or PAL analog Color Black 
signal. The External Reference input can come from two different sources on the R20CE. 
There are jumpers on the R20CE (see figure below) for selecting the external reference 
source and for optionally terminating the selected reference source.

 

Looping Reference

 

The R20CE cell group of 9 BNCs contains two BNCs that can be used for a looping 
reference connection. If this method is used, then the reference select setting on the R20CE 
should be set to “LOOP” and the TERMINATION setting should be set to “OFF” (no 
termination). Optionally, if you’re using only one of the looping reference BNCs, then the 
TERMINATION setting should be set to “ON.”

 

Frame Reference

 

Alternatively, the R20CE installed in a FR1 or FR2 frame can use the frame’s 

 

frame reference 

input 

 

BNC connector, which feeds an external reference video signal to all modules 

installed in the frame. How the signal is distributed differs for the FR1 and FR2 frames. 
Additionally, individual modules can usually be strapped as to whether external reference is 
distributed from the frame or directly to BNCs on the module’s corresponding cell group 
(the 9 BNCs on the rear panel). 

 

FR1 Frame: 

 

the external reference signal is distributed passively to all frame modules. 

If you wish to use the frame reference, the R20CE should have “FRAME” 
reference selected on the module strapping, and one and only one card in the 
frame should have “TERMINATION” set to “ON.” All other cards in the frame 
should have TERMINATION set to “OFF.”

 

FR2 Frame: 

 

the external reference signal is distributed by an in-frame distribution 

amplifier to all frame modules. This system terminates the Frame Reference 
input BNC and buffers the signal to all slots. If using frame reference, the 
R20CE installed in the FR2 frame should have “FRAME” set for reference select, 
and all cards should have TERMINATION set to “OFF.”

Содержание R20CE

Страница 1: ...R20CE 10 bit Encoder R series Card Module User Manual August 8 2007 P N 101646 00...

Страница 2: ...arranty period AJA Video at its option will either repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtai...

Страница 3: ...along with the precision 4x oversampled D A filters provides high quality analog outputs with very low phase noise in the composite outputs The optional AJA model FSG Frame Sync Genlock Module allows...

Страница 4: ...s versus the FR1 FR2 frame reference BNC when connecting an external reference video signal 1 2 Cable EQ Serial Video In Serial Parallel REF LOOP FRAME REF Filter Filter Filter Filter Filter Cable Dri...

Страница 5: ...FF type functions such as Setup NoSetup selection moving the toggle switch to the UP LEFT position sets the function and moving the switch DOWN RIGHT clears the function Using the toggle with multi va...

Страница 6: ...5 COMPONENT LEVELS UP LEFT BETACAM 525 Y R Y B Y DOWN RIGI T SMPTE EBU N 10 BETACAM 625 Y Pb Pr When OUTPUT MODE Y Pb Pr 6 INPUT SOURCE Toggle DOWN to pass video Toggle UP for Bars Internal test signa...

Страница 7: ...UP LEFT increases OutputDelay by lines Toggle DOWN RIGHT Decreases Output Delay by lines 3 SET PIXEL DELAY Toggle UP LEFT increases Output Delay by pixels Toggle DOWN RIGHT Decreases Output Delay by p...

Страница 8: ...ermination Optionally if you re using only one of the looping reference BNCs then the TERMINATION setting should be set to ON Frame Reference Alternatively the R20CE installed in a FR1 or FR2 frame ca...

Страница 9: ...Delay mode In Genlock mode the R20CE output genlocks to the external reference The board can be set to Delay mode without removing the external reference by lifting the REFERENCE SELECT jumper J3 Gen...

Страница 10: ...iming in line increments 3 Perform function 3 in Bank 1 SET PIXEL DELAY This allows you to advance and delay the output timing in Pixel increments Note In SET PIXEL DELAY the first four increments are...

Страница 11: ...Output Equalized Re clocked Return Loss Serial Input 15 dB to 300MHz Serial Output 15 dB to 300MHz FrequencyResponse 0 25dB to 5 5MHz Y 0 25dB to 2 0Mhz Chroma Component RGB 0 25dB to 1 3Mhz Chroma Co...

Страница 12: ...12...