Aiwa TD-P10 Скачать руководство пользователя страница 2

EMI/EMC

  FCC Part 15B, Class B

FCC NOTICE

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
.... Reorient or relocate the receiving antenna.
.... Increase the separation between the equipment and receiver.
.... Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

.... Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the manufacturer could void
the user's authority to operate the equipment.

Caution

Shielded I/O cables must be used when operating this equipment.
A shielded power cable must be used when operating this equipment.

  C108.8-M1983, Class B

Industry Canada Compliance statement:

This equipment does not exceed class B limits for radio noise emissions for digital
apparatus set out in the Radio Interference Regulation of the Industry Canada. Operation
in a residential area may cause unacceptable interference to radio and TV reception
requiring the owner or operator to take whatever steps are necessary to correct the
interference.

Avis de conformité aux normes du ministère de l'Industrie du Canada:

Cet équipement ne dépasse pas les limites de Classe B d'émission de bruits
radioélectriques pour les appareils numériques telles que perscrites par le Règlement
sur le brouillage radioélectrique établi par le ministère de l'Industrie Canada.
L'exploitation faite en milieu résidentiel peut entraîner le brouillage des réceptions radio
et télé, ce qui obligerait le propriétaire ou l'opérateur à prendre les dispositions
nécessaires pour en éliminer les causes.

Safety

UL 1950 IEC 950 A1, +A2, +A3

cUL-22.2-950 A1, +A2, +A3

Содержание TD-P10

Страница 1: ...ntact your AIWA dealer in case of difficulty Model No Serial No TD P10 Hardware Installation Manual To Call Technical Support 800 920 2673 8 00AM to 5 00PM pacific time Monday through Friday WARNING T...

Страница 2: ...technician for help Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Caution Shielded I O cables must be used when opera...

Страница 3: ...d Write Head 18 Installation of the Backup Software 20 Troubleshooting 23 Technical Support 25 Specifications 27 AIWA BOLT is a trademark of Aiwa Co Ltd QIC EXtra is a trademark of Verbatim Corporatio...

Страница 4: ...le spacing from walls and other obstructions so that there is a clear passage of air to the fan Operating the unit when the fan is obstructed can lead to malfunctions Take great care when carrying the...

Страница 5: ...nsioning pass running the tape from end to end is strongly recommended when a the cartridge is first loaded into a drive b the cartridge is exposed to temperature changes of 16 C or more or c one sect...

Страница 6: ...ng and the printed results cannot be guaranteed The effect of attempting to use the tape drive during printing is similar When turning on the computer Be sure to turn on the tape drive first before tu...

Страница 7: ...BOLT 10GB tape cartridge using the backup software suppplied with this unit This unit can read and write data which has been compressed by software at a compression rate of 2 1 at a maximum backup spe...

Страница 8: ...Cartridges QIC Format Format Model Number Tape Length Type Manufacturer QIC 3020 QIC EXtra Verbatim TR 3 EXtra 1 000 ft MC 3020 EXtra 1 000 ft TRAVAN Imation 3M TR 3 750 ft QIC WIDE Sony QW3020XLF 400...

Страница 9: ...to use this unit with a computer whose parallel port supports the EPP Enhanced Parallel Port mode or the ECP Extended Capabilities Port mode Data backup speed may be considerably slowed down when usin...

Страница 10: ...omputer make sure that the package contains the following items Note Remember to keep all packing materials for later use especially the polystyrene foam cushioning and the antistatic bag which contai...

Страница 11: ...r ACCESS indicator POWER indicator Tape cartridge slot Printer connector TO PRINTER Interface connector TO COMPUTER Cooling fan underneath Connector cover When connecting nothing to the printer connec...

Страница 12: ...tally or vertically Set the unit on a flat place Do not however place the unit with its bottom or the LED side facing upward Note Do not use this unit where it may be subject to vibration or shock NOT...

Страница 13: ...ect the printer cable from the computer 3 Plug the connector detached in step 2 to the printer connector TO PRINTER on the rear of the tape drive Note The connector cover for the printer connector on...

Страница 14: ...nnectors with a screwdriver or coin if they are too tight to undo by hand Fasten the connector screws by hand If it is necessary for any reason to use a screwdriver or coin be very careful not to over...

Страница 15: ...The printer 3 The computer Note If you turn on the computer before turning on the tape drive you cannot control the tape drive from the computer Press the upper side of the power switch on the rear to...

Страница 16: ...ocked position Inserting and Removing Tapes Hold the tape cartridge and insert it as illustrated below Push the cartridge in until it locks into place with a click When the cartridge is loaded the ACC...

Страница 17: ...ow the state of the unit as shown below Note If the ACCESS indicator blinks in red remove the cartridge from the unit then re insert it If the indicator still blinks in red use a new tape cartridge Wa...

Страница 18: ...the read write head One is the method to use the Geneva C3 IRTTAPE Cleaning Cartridge or Imation TRAVAN NS Dry Process Head Cleaning Cartridge Another is the method to use a swab which is dampened wit...

Страница 19: ...the read write head up and down as shown below For cleaning you may use a lint free cotton swab moistened with more than 90 isopropyl alcohol Wait for at least 10 minutes for the head to dry completel...

Страница 20: ...ive to install the backup software 2 The CD Browser is displayed automatically on the Windows 95 Windows 98 desktop Choose Seagate Backup Exec for Windows 95 Windows 98 then click the installation but...

Страница 21: ...Exec program itself has not yet been installed be sure to install the External Port Driver from the CD ROM before installing and using the Direct Tape Access Note Depending on the circumstances it ma...

Страница 22: ...d check the DMA option in Settings tab as shown below Installation of the Backup Software Note To use the Recovery Diskette with the PC which does not support the EPP mode If your PC does not support...

Страница 23: ...priate cartridge See page 7 A 10 GB backup is not possible on an AIWA BOLT formatted AIWA BOLT 10GB a The basic capacity of an AIWA BOLT 10GB is 5 GB The figure of 10 GB assumes software data compress...

Страница 24: ...rocessing speed may be inadequate c Use the Tape Tool provided as part of the backup software to retension the tape This may eliminate the problem d The read write head may be dirty Carry out head cle...

Страница 25: ...the computer system has been recently moved d Ensure that all add on cards are properly seated and that the settings correspond to the configuration requirements e Make sure the unit is in an area whe...

Страница 26: ...ment The original packaging used by AIWA included an anti static bag to protect the product Use both the original anti static bag and the exterior box or an equivalent anti static bag and box if an AI...

Страница 27: ...h no other job to be executed by the CPU 2 00 Mbps QIC 3020 Format only Power requirements 120 V AC 60 Hz 0 45A Operating temperature 10 C to 35 C 50 F to 95 F Relative humidity 20 to 80 no condensati...

Страница 28: ...88 XSY 901 11 981224BMK H Y0 Printed in Japan AIWA CO LTD...

Отзывы: