– 42 –
<FRONT >
1. Clock Adjustment
Requirement:
•
Measuring instrument: Frequency counter
•
Test point: TP3 (KSCAN), GND
•
Adjustment point: L951
1) While pressing and holding down the POWER button and UP button, Insert the AC plug to outlet.
2) Adjust L951 so that the frequency counter indicates 84.804±0.084Hz.