background image

31

Subject to technical amendments without prior notice  |  83059300iUK  |  ait-deutschland GmbH

Sheet

Page

=MA1

+SS1

Installation circuit diagram

1

0

7

6

8

9

3

7

4

1

2

5

7

/

831223a

ait-deutschland GmbH

Industriestraße 3

95359 Kasendorf

Germany

MAP

Checked by

Changed on

04.04.2022

KAF

11.03.2022

Creator

Created on

Changed by

KAF

Item no

Circuit diagram

Install. Nr

&EFZ

Refer to protection notice ISO 16016.

HDV9 Versorgung

Doc. no.

Revision

a

X9

X8

PE

X9

N

L1

L2

L3

1x230V 50Hz / N / PE

Power supply electric heating element

1x230V 50Hz / N / PE

Power supply control

Sub-distribution unit internal installation

Please refer to the technical data for fuse protection!

UK

831223a

PE

X8

N

L1

L2

L3

1x230V 50Hz / N / PE

Power supply compressor

FKU1

FKU2

FKU3

X8

X9

X10

Circuit breaker electric heating element

Terminal for compressor

Terminal for electric heating element

Terminal for control

Circuit breaker compressor

Circuit breaker control

Equipement

Description

X10

FKU1

FKU2

FKU3

N1-5

X10

L

N

PE

N

PE1-5

PE

N

PE

HS(D)V 9M1/3

  Terminal diagram, mains connection heat pump 1~230V 

+ electric heating element 1~230V

Содержание HSDV 12.1M3

Страница 1: ...UK 83059300iUK Accessories for heat pumps Operating Manual Hydraulic Station...

Страница 2: ...on 12 8 Installing the control panel 14 9 Flushing filling and venting 14 9 1 Heating water quality 14 9 2 Flush and fill the heating and domestic hot water charging circuit 15 9 3 Flushing filling an...

Страница 3: ...he heating and heat pump controller Brief description of the heat pump controller Operating manual of the expansion board acces sories Log book 1 3 Symbols and markings Identification of warnings Symb...

Страница 4: ...s and the resulting consequences must be instructed and if necessary supervised by persons experienced in handling the product and who are re sponsible for safety Children must not play with the produ...

Страница 5: ...rial fatigue Gas bubbles and gas cushion formation cavita tion Negative effect on heat transfer e g formation of coatings deposits and associated noises e g boiling noises flow noises Note and follow...

Страница 6: ...Any defects or incorrect deliveries must be report ed immediately 4 1 Accessories The following accessories are available for the device through the manufacturer s local partner Expansion circuit pri...

Страница 7: ...g and transport Notes on safe transport The device is heavy Technical data Scope of supply from page 19 There is a risk of injuries or damage to property if the device falls or overturns The hydraulic...

Страница 8: ...hot water temperature sensor through its grommet in the support plate and place it behind the support plate Be careful not to damage the cable 6 Re attach the hydraulics and hood after aligning the un...

Страница 9: ...decoupled from structure borne noise 2 Tilt the device slowly and carefully to one side 3 Secure the tilted device to ensure that it cannot tip back to its initial position 4 Fit the adjustable feet t...

Страница 10: ...tion are also taken into account 9 Freely pressing the recirculating pump produces at least the minimum throughput required for the device type Free pressing page 21 Route all hydraulic connections as...

Страница 11: ...whether the size of the expansion ves sel is large enough for the system If necessary an ad ditional expansion vessel must be installed on site in accordance with the relevant valid standards NOTE Th...

Страница 12: ...r apart 100 mm Maximum line length 30m Cable extension details see operating manual of the heat pump Establish the electrical connections between the heat pump and the hydraulic station Operating manu...

Страница 13: ...phase operation Disconnect Q5 6 for this Or 3 kW 2 kW 1 phase op eration Disconnect Q5 6 and Q5 4 for this The values in brackets are for the 6 kW heat ing element Disconnected cables must be furnishe...

Страница 14: ...idelines 2035 Ver meidung von Sch den in Warmwasserhei zanlagen preventing damage in hot water heating systems Required pH value 8 2 10 for aluminium materials pH value 8 2 8 5 Fill the system with de...

Страница 15: ...system at the highest point 2 Open the vent valve on the 3 way switching valve 1 3 Pull off the U clip on the back of the valve mo tor on the switching valve upwards 2 3 4 Carefully pull the valve mot...

Страница 16: ...flushing and filling the domestic hot water tank the outlet pipe of the safety valve must be con nected The set pressure of the safety valve must not be exceeded 1 Open the domestic cold water supply...

Страница 17: ...aration and building heating 1 The volumetric flow meter heat meter measures flow and temperature difference in the charging circuit The measuring ranges are set in the heating and heat pump controlle...

Страница 18: ...the centre of the safety temperature limiter located underneath the cover has tripped If the reset button has tripped press it again using a small screwdriver 2 1 3 If the safety temperature limiter t...

Страница 19: ...raw off of 10 l min l 230 365 Standing loss according to ErP 2009 125 EC at 65 C W 55 66 Maximum pressure Operating pressure bar bar 6 10 13 6 10 13 Electrics Voltage code all pole fuse protection for...

Страница 20: ...C at 40 C draw off of 10 l min l 230 365 Standing loss according to ErP 2009 125 EC at 65 C W 55 66 Maximum pressure Operating pressure bar bar 6 10 13 6 10 13 Electrics Voltage code all pole fuse pro...

Страница 21: ...Bornmann 10 04 2018 823288 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 0 0 5 1 0 1 5 2 0 2 5 3 0 pmax bar pmax p m3 h Legende Volumenstrom Heizwasser in m3 h pmax maximale freie Pressung 823312 0 0 0 1...

Страница 22: ...1 internal thread 3 3 Heating water outlet flow Heating water outlet flow Rp 1 internal thread Rp 1 internal thread 4 4 Control panel Control panel 5 5 Emptying buffer tank Emptying buffer tank G 1 2...

Страница 23: ...Control panel Control panel 5 5 Emptying buffer tank Emptying buffer tank Rp 1 2 internal thread Rp 1 2 internal thread 6 6 Hot water inlet from heat pump Hot water inlet from heat pump Rp 1 internal...

Страница 24: ...Ma e in mm OKF Oberkante Fertigfussboden FS Freiraum f r Servicezwecke 4 3 2 1 A B C D E F 4 3 2 1 Schutzvermerk ISO 16016 beachten Keys UK819418 Keys UK819418 All dimensions in mm All dimensions in m...

Страница 25: ...FS Freiraum f r Servicezwecke Technische nderungen vorbehalten OKF 4 3 2 1 A B C D E F 4 3 2 1 Zus Schutzvermerk ISO 16016 beachten Keys UK819490 Keys UK819490 All dimensions in mm All dimensions in...

Страница 26: ...75mm 2x0 75mm IMPORTANT The cable cross sections shown are only intended as a guideline for the electrician They must be adapted to the regional regulations and the conditions of use e g cable length...

Страница 27: ...ignal of additional heat generator 2 alternative is general malfunction ZIP circulation pump FP1 Pump for mixing circuit 1 ZUP Auxiliary circulation pump HUP Heating circuit circulating pump BUP Domes...

Страница 28: ...0 75mm 2x0 75mm IMPORTANT The cable cross sections shown are only intended as a guideline for the electrician They must be adapted to the regional regulations and the conditions of use e g cable lengt...

Страница 29: ...heat generator 2 alternative is general malfunction ZIP circulation pump FP1 Pump for mixing circuit 1 ZUP Auxiliary circulation pump HUP Heating circuit circulating pump BUP Domestic hot water temper...

Страница 30: ...L2 L3 3x400V 50Hz N PE Power supply electric heating element 1x230V 50Hz N PE Power supply control Sub distribution unit internal installation Please refer to the technical data for fuse protection U...

Страница 31: ...N L1 L2 L3 1x230V 50Hz N PE Power supply electric heating element 1x230V 50Hz N PE Power supply control Sub distribution unit internal installation Please refer to the technical data for fuse protecti...

Страница 32: ...heating element 1x230V 50Hz N PE Power supply control Sub distribution unit internal installation Please refer to the technical data for fuse protection UK 831221a PE X8 N L1 L2 L3 3x400V 50Hz N PE Po...

Страница 33: ...m Install Nr EFS Refer to protection notice ISO 16016 HSV9M 1 3 Doc no Revision a PE N L1 X9 L2 L3 3x400V 50Hz N PE 1 2 Q5 2 5 3 4 5 6 Supply heating element UK 817472a E22 VD1 BK BN GNYE WH WH BK BN...

Страница 34: ...er supply control X10_N1_1 2 9 X10_PE4_3 3 4 X10_PE2_3 3 4 L N PE UK 817472a IN2 X3 2 OUT1 X3 1 L X4 L X4 IN3 X3 2 GND X6 A X6 OUT7 X3 1 K10 3 1 EFZ 1 3 EFZ 1 7 PE X0 N X0 L X0 AIN1 X9 AGND1 X9 AOUT1...

Страница 35: ...tection notice ISO 16016 HSV9M 1 3 Doc no Revision a UK 817472a R3 TBW R5 TVL R4 TRL K11 EFZ 1 8 1 2 LIN 3 GND 4 12V RJ45 K10 2 1 GND3 X5 1 NTC3 X5 1 GND6 X5 1 NTC9 X5 2 GND9 X5 2 NTC6 X5 1 GND8 X5 2...

Страница 36: ...room M5 Q5 K10 X8 X100 MR1 Power supply control MOD BUS Energy supplier contact closed on release bridge if no blocking interval XSE Sensorcard X200 X10 EVU K11 Control unit R3 Domestic hot water tem...

Страница 37: ...r to protection notice ISO 16016 HSDV9 Doc no Revision a PE N L1 X9 L2 L3 3x400V 50Hz N PE 1 2 Q5 2 5 3 4 5 6 Supply heating element UK 817476a E22 VD1 BK BN GNYE WH WH BK BN PE N L1 X8 L2 L3 1x230V 5...

Страница 38: ...9 L N PE UK 817476a B2 WH GN BN IN2 X3 2 OUT1 X3 1 L X4 L X4 IN3 X3 2 GND X6 A X6 OUT7 X3 1 K10 3 2 EFZ 1 3 EFZ 1 7 PE X1 N X1 L X1 AIN1 X9 AGND1 X9 AOUT1 X9 12VDC 5VDC Y1 BUP BN BK GY 13 14 Q5 2 5 A1...

Страница 39: ...r EFS Refer to protection notice ISO 16016 HSDV9 Doc no Revision a UK 817476a R3 TBW R5 TVL R4 TRL K11 EFZ 1 8 1 2 LIN 3 GND 4 12V RJ45 X20 EFZ 1 7 1 X1 2 X1 3 X1 4 X1 1 X6 K10 2 1 GND3 X5 1 NTC3 X5 1...

Страница 40: ...room M5 Q5 K10 X8 X100 MR1 Power supply control LIN Bus Energy supplier contact closed on release bridge if no blocking interval Domestic hot water valve Y1 XSE Sensorcard X200 X10 EVU K11 Control un...

Страница 41: ...41 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...

Страница 42: ...42 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...

Страница 43: ...43 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...

Страница 44: ...UK ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu...

Отзывы: