15
Subject to technical amendments without prior notice | 83059300iUK | ait-deutschland GmbH
9.2
Flush and fill the heating and
domestic hot water charging
circuit
Outlet pipe of the safety valve is connected.
►
Ensure that the set pressure of the safety valve is
not exceeded.
NOTE
The venting programme on the controller can
also be used to support the flushing and vent
-
ing process. It is possible to control individual
recirculating pumps and also the switchover
valve via the venting programme. As a result,
it is not necessary to remove the valve motor.
1. Vent the system at the highest point.
2. Open the vent valve
(①)
on the 3-way switching
valve.
1
3.
Pull off the U-clip
(②)
on the back of the valve mo-
tor
(③)
on the switching valve (
④
)
upwards
.
2
3
4. Carefully pull the valve motor
(③)
forward off the
3-way switching valve
(④)
.
4
3
5. Turn the spindle of the 3-way switching valve so
that the rounded side of the spindle points in the
direction of marking A of the connections of the
3-way switching valve.
A
B
6. Flush the domestic hot water charging circuit for
approx. 1 minute.
7. Turn the spindle so that the rounded side of the
spindle points in the direction of marking B of the
connections of the 3-way switching valve.
8. Flush heating circuit thoroughly, until no more air
is discharged.
9. Position the valve motor
(③)
on the 3-way switch-
ing valve
(④)
.
4
3
Содержание HSDV 12.1M3
Страница 1: ...UK 83059300iUK Accessories for heat pumps Operating Manual Hydraulic Station...
Страница 41: ...41 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 42: ...42 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 43: ...43 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 44: ...UK ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu...