20
Subject to technical amendments without prior notice | 83059300iUK | ait-deutschland GmbH
Accessories for heat pump type
HSDV 9M1/3
HSDV 12.1M3
Air/water 8 kW output-controlled | Air/water 12 kW output-controlled
• yes – no
– | –
– | –
Air/water dual output-controlled
• yes – no
•
•
Air/water 7 kW to 8 kW output-controlled | Air/water 10 kW to 18 k
Outdoor installation
• yes – no
– | –
– | –
Air/water 9 kW to 14 kW RX
Outdoor installation
• yes – no
–
–
Air/water dual
Outdoor installation
• yes – no
–
–
Air/water dual RX
Outdoor installation
• yes – no
–
–
Installation location
Room temperature
min. | max.
°C
5 | 35
5 | 35
Relative humidity
%
60
60
Sound
Sound pressure level at 1 m distance
inside
dB(A)
33
33
Sound power level
inside
dB(A)
46
46
Heating circuit
Flow rate: minimum | maximum (see heat pump for pipe dimensioning)
l/h | l/h
700 | 1600
700 | 1600
Free pressing | Pressure loss | Flow rate
bar | bar | l/h
0,65 | – | 1150
0,81 | – | 1150
Max. allowable operating pressure
bar
3
3
Circulation pump control range
min. | max.
l/h
600 ı 1200
600 ı 1900
General unit data
Total weight
kg
150
161
Weight of individual components
kg | kg | kg
– | – | –
– | – | –
Domestic hot water tank
Net volume
l
180
279
Magnesium sacrificial anode
Impressed current | Magnesium
• yes – no
– | •
– | •
Domestic hot water temperature, heating pump mode | Electric heating element
up to °C | up to °C
60 | 65
60 | 65
Mixed water quantity according to ErP: 2009/125/EC (at 40 °C, draw-off of 10 l/min)
l
230
365
Standing loss according to ErP: 2009/125/EC (at 65 °C)
W
55
66
Maximum pressure | Operating pressure
bar | bar
6 | 10 | 13
6 | 10 | 13
Electrics
Voltage code | all-pole fuse protection for heat pump *)**)
1 phase
… | A 1~N/PE/230V/50Hz | B16
1~N/PE/230V/50Hz | B16
Voltage code | all-pole fuse protection for heat pump *)**)
3 phases
… | A
– | –
– | –
Voltage code | Control voltage fuse protection **)
… | A 1~N/PE/230V/50Hz | B16
1~N/PE/230V/50Hz | B16
Voltage code | Electric heating element fuse protection **)
1 phase
… | A 1~N/PE/230V/50Hz | B25
– | –
Voltage code | Electric heating element fuse protection **)
3 phases
… | A 3~N/PE/400V/50Hz | B10
3~N/PE/400V/50Hz | B16
Degree of protection
IP
20
20
Residual current circuit breaker
if required
type
B
B
Electric heating element output
3 | 2 | 1 phase
kW | kW | kW
6 | 4 | 2
9 | 6 | 3
Circulation pump power consumption, heating circuit
min. | max.
W
4 | 75
4 | 75
Other unit information
Safety valve Heating circuit | Response pressure
included in scope of supply: • yes – no | bar
• | 3
• | 3
Buffer tank | Volume
included in scope of supply: • yes – no | l
• | 62
• | 83
Diaphragm expansion vessel Heating circuit | Volume | Prepressure
incl. in scope of supply: • yes – no | l | bar
• | 12 | 1,5
• | 12 | 1,0
Overflow valve | Changeover valve, heating -Domestic hot water
integrated: • yes – no
• | •
• | •
Vibration decoupling, Heating circuit | Heat source
included in scope of supply or integrated: • yes – no
–
–
Controller | Heat quantity recording | Extension board
included in scope of supply or integrated: • yes – no
• | • | –
• | • | –
813324a
813327b
*) compressor only, **) note local regulations
Technical data / Scope of supply
HSDV…
Содержание HSDV 12.1M3
Страница 1: ...UK 83059300iUK Accessories for heat pumps Operating Manual Hydraulic Station...
Страница 41: ...41 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 42: ...42 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 43: ...43 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Страница 44: ...UK ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu...