VENTILATION FAN  

TM  

 

Model: SE80RVL   SE80RVLH  
WARNING  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number  
  listed in the warranty.  
2.  Before  servicing  or  cleaning  unit,  switch  power  off  at  service  panel  and  lock  the  service  disconnecting  means  to  prevent  power  from  being  switching  on  
  accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.  
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and  standards, including fire-rated  
  construction codes and standards.  
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.  

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and 
the American Society for Heating, Refrigeration and Air Conditioning   Engineers (ASHRAE), and the local code authorities.  

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.  
6. Ducted fans must always be vented to the outdoors.  
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).  
8. This unit must be grounded.  

CAUTION  

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.   
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT   
  THIS PRODUCT IN A WALL.  
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power  unit.  
4. Please read specification label on product for further information and requirements.  

CLEANING & MAINTENANCE  

For quiet and efficient operation, long life, and attractive appearance  - lower or remove grille and vacuum interior of unit with the dusting 
brush attachment.  
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, rep lace the 
motor with the exact service motor. The impeller should also be replaced.   

OPERATION  

Use an on/off switch to operate this 

fan. See “Connect Wiring” for details.  

The humidity control and fan can be operated separately. Use a 1 or 2 function wall control. Do not use a dimmer switch to op erate the 

humidity control or light. See “Connect Wiring” for details.  
For SE80RVLH  

SENSOR OPERATION  

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in humidity or 
(b)  humidity  above  a  user-adjustable  set-point  (50%-100%  relative  humidity).  The  humidity  sensor  may  occasionally  turn  the  fan  ON  when 
environmental conditions change. If the fan continuously responds to changing environmental conditions, “H” (means “humidity”) adjustment 
may be required. This figure is factory-set for about 75% (Ambient temperature of 25¥)  

SENSITIVITY ADJUSTMENT  

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H”  
may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, movement toward less 

“-” “H” may be required.  
To adjust the “H”:  
1. Disconnect power at service entrance.  

2. Through the grille, locate the slot marked “H”.  
3. Carefully rotate the “H” adjustment toward “+” or “-”.  
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.   
5. Repeat above steps if necessary.  
When the temperature changes, humidity sensor values will have deviation.   

TIMER ADJUSTMENTC  

The hum

idity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes). This “T” controls the 

length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity and the humidity level is below the user-adjustable set-point. 
To adjust the “T”:  
1. Disconnect power at service entrance;  
2. Through the grille, locate the slot marked “T”;  
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).  
4. Check operation by turning on a humidity source until the fan turns on.  
5. Turn humidity source off and time the unit.  
6. Repeat above steps if necessary.  

 

READ AND SAVE THESE INSTRUCTIONS  

Installer: Leave this manual with the homeowner.  