ICE EX04-18 Heat I&O Manual 06/2020 Rev.1

 

2

How To Use This Manual 

This manual is intended to be a guide to Industrial Climate Engineering’s line of Heat Exchanger 

(EX Series) Cabinet Climate Control Units. It contains installation, troubleshooting, maintenance, 

warranty, and application information. The information contained in this manual is to be used 

by the installer as a guide only. This manual does not supersede or circumvent any applicable 

national or local codes.
If you are installing the air conditioner first read Chapter 1 and scan the entire manual before 

beginning the installation as described in Chapter 2.  Chapter 1 contains general, descriptive 

information and provides an overview, which can speed up the installation process and simplify 

troubleshooting.
If a malfunction occurs, follow this troubleshooting sequence: 

1. Make sure you understand how the heat exchanger works (Chapters 1 & 3).
2. Identify and correct installation errors (Chapter 2).
3. Refer to the troubleshooting information (Chapter 4).

If you are still unable to correct the problem, contact the Factory at 1-229-273-9558 for additional 

assistance.

Please read the following “Important Safety Precautions” before beginning any work.

Important Safety Precautions

1. USE CARE when LIFTING or TRANSPORTING equipment. 
2. TRANSPORT the UNIT UPRIGHT. Laying it down on its side may cause the fan to shift  

in its mounting or damage to other components.

3. TURN ELECTRICAL POWER OFF AT THE breaker or fuse box BEFORE installing or 

working on the equipment.  LINE VOLTAGES ARE HAZARDOUS or LETHAL.       

4. OBSERVE and COMPLY with ALL applicable PLUMBING, ELECTRICAL, and 

BUILDING CODES and ordinances.                                               

5. SERVICE  may  be  performed  ONLY  by  QUALIFIED  and  EXPERIENCED  PERSONS.                

 

*  Wear safety goggles when servicing the refrigeration circuit

 

*  Beware of hot surfaces on refrigerant circuit components   

 

*  Beware of sharp edges on sheet metal components 

 

*  Use care when recovering or adding refrigerant                             

6. Use COMMON SENSE - BE SAFETY-CONSCIOUS

This is the safety alert symbol  

 . When you see this symbol on the air conditioning unit and in the 

instruction manuals be alert to the potential for personal injury. Understand the signal word DANGER, 
WARNING and CAUTION. These words are used to identify levels of the seriousness of the hazard.

DANGER

Failure to comply will result in death or severe personal injury and/or 

property damage.

WARNING

Failure to comply could result in death or severe personal injury and/or 

property damage.

CAUTION

Failure to comply could result in minor personal injury and/or property 

damage.

IMPORTANT

Used to point out helpful suggestions that will result in improved 

installation, reliability or operation.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

© 06/2020 Industrial Climate Engineering

®

 Div. Airxcel

, Inc.

Содержание EX04CDHC1A

Страница 1: ...10 2002 Hoover St Cordele Georgia 31015 229 273 9558 Fax 229 273 5154 E mail icesales airxcel com Internet www acice com Models EX04CDHC1A EX08CDHC1C EX12CDHC1B EX18CDHC1A Installation Operation Manua...

Страница 2: ...TRANSPORT the UNIT UPRIGHT Laying it down on its side may cause the fan to shift in its mounting or damage to other components 3 TURN ELECTRICAL POWER OFF AT THE breaker or fuse box BEFORE installing...

Страница 3: ...panel END USER Retain these instructions for future reference Table of Contents Chapter 1 Description Specifications 1 1 Foreword 4 1 2 General Description 4 1 3 Features 5 1 4 Standards 5 Chapter 2...

Страница 4: ...nalheatloadchanges anyfaultcanbereadremotelythroughtheRS485interface monitoring system The EX Series heat exchanger works as shown in Figure 1 the unit s internal loop draws heated air from upper open...

Страница 5: ...nits if any is present make a note and inform Industrial Climate Engineering together with the bar code number on the package within 7 days 2 If the product will not be immediately installed or is to...

Страница 6: ...tion or repairs made by unqualified persons could result in hazards to you and others Installation MUST conform with local codes or in the absence of local codes with codes of all governmental authori...

Страница 7: ...e table 2 1 9PIN terminal definitions Monitoring Output The RS485 monitoring connector definition is following Pin Definition RS485 RS485 communication ports up stream equipment monitoring interface R...

Страница 8: ...Close the circuit breaker and the unit will automatically begin operating When the temperature inside the cabinet rises above the preset value the external fan will increase to maximum speed Chapter 3...

Страница 9: ...ing Range Units Description High Temperature Alarm 55 25 80 C The temperature point of the High Temperature alarm Low Temperature Alarm 0 25 15 C The temperature point of the Low Temperature alarm Tab...

Страница 10: ...terface ON OFF ON OFF Button long press this button about 4s this can be used to turn on off the unit Up Button which is used to select the previous record menu or increase the setting value password...

Страница 11: ...u structure not the factory setting Chapter 4 Maintenance WARNING All maintenance shall be performed by qualified persons Always disconnect the power communication and alarm output cables from the hea...

Страница 12: ...wer have been disconnected 2 Dismantle the inner fan 3 Disconnect the wiring of the controller 4 Dismantle the controller 5 Reverse the steps 2 3 4 to mount the new controller 4 4 Heater Optional If t...

Страница 13: ...Drainpipe is not dirty block Table 6 Maintenance Checklist 4 7 Disposal DISPOSAL Properly dispose of this product Chapter 5 Troubleshooting 5 1 Troubleshooting Guide Symptom Possible Cause Solution U...

Отзывы: