5-10
PERFORMANCE DATA & PRESSURE CURVES
SM FBFRPM 1-A.0 GB
5.7.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
WB OU COIL (
°
C)
ENTERING AIR DB ID COIL (
°
C)
15
20
25
TH
PI
TH
PI
TH
PI
-10
5.36 2.74 5.15 2.92 4.95 3.07
-7
5.76 2.81 5.56 2.97 5.36 3.13
-2
6.12 2.85 5.92 3.02 5.71 3.19
2
7.45 2.98 7.14 3.17 6.83 3.36
6
10.51 3.21
10.20 3.43
9.84 3.64
10
11.42 3.39 11.12 3.62 10.81 3.87
15
12.34 3.53 12.04 3.81 11.73 4.05
20
13.01 3.64 12.70 3.94 12.34 4.25
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH – Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OU –
Outdoor
5.8
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.8.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Содержание YCF055
Страница 45: ...8 2 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 3 Indoor Units YDF030 8 4 Outdoor Unit GCN 30NRCT...
Страница 46: ...8 3 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 5 Outdoor Unit GCN 37NRC 8 6 Outdoor Unit GCN 37NRCT...
Страница 47: ...8 4 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 7 Outdoor Unit YDF047 8 8 Outdoor Unit YCF055...
Страница 50: ...10 2 REFRIGERATION DIAGRAMS SM FBFRPM 1 A 0 GB 10 1 2 FBF045 FBF060...
Страница 92: ...14 4 EXPLODED VIEWS AND SPARE PARTS LISTS SM FBFRPM 1 A 0 GB 14 4 Indoor Unit FBF046 FBF060...
Страница 109: ...15 3 OPTIONAL ACCESSORIES SM FBFRPM 1 A 0 GB 15 3 RCW RCW2 Wiring Connections as Shown on Kit...