![Airwell YBZ214 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/airwell/ybz214/ybz214_service-manual_2879932046.webp)
CONTROL
SYSTEM
12-6
Service Manual – YBZ DCI 1-A.1 GB
12.4.2.1 All indoors to inactive
Compressor stops immediately, OFAN stops after 1 min.
12.4.2.2 Partial indoors to inactive
Recalculate the load immediately, for Inactive indoors, EEV opening will follow
12.1.5.5.
12.4.3
OFAN control during Heat Mode
OFAN will start 5sec before compressor starts. After starting, it will run at High speed for 40 sec
then switch to the requested speed.
OFAN will run at one speed for at least 80sec.
After compressor stopping, the OFAN will keep the current speed for 1min and then stop.
12.4.4
Oil return operation during Heat Mode
12.4.4.1 Starting oil return
Oil return operation is to avoid compressor operating with low frequency for long time.
12.4.4.2 Oil return operation
Indoor display shows “H1”
System will run at Cool Mode. Compressor is forced to run higher frequency. And both IFAN and
OFAN are stopped.
12.4.4.3 Exiting oil return
The oil return operating time reaches 5min (Including frequency’s changing time)
12.4.5
Indoor Fan Control in Heat Mode
Indoor fan speed depends on the indoor coil temperature
Anti-cold air function
When starting the heating mode, anti-cold air function will be activated and indoor fan can run at low
speed or stop running. This function will terminate after the unit runs for 3min or the ICT reaches 42
degree.
Residual heat blowing function
During heating, when the stopping condition for the compressor is reached, the compressor and the
outdoor fan motor stop running while the louver moves to position L. The indoor fan will stop after
running for 60s at setting speed.
Содержание YBZ214
Страница 16: ...OUTLINE DIMENSION 4 2 Service Manual YBZ DCI 1 A 1 GB 4 2 Indoor HZD018 HYD018...
Страница 17: ...OUTLINE DIMENSION Service Manual YBZ DCI 1 A 1 GB 4 3 4 3 Outdoor YBZ214...
Страница 18: ...OUTLINE DIMENSION 4 4 Service Manual YBZ DCI 1 A 1 GB 4 4 Outdoor YBZ318 YBZ430...
Страница 35: ...WIRING DIAGRAM 9 2 Service Manual YBZ DCI 1 A 1 GB 9 3 YAZ214...
Страница 36: ...WIRING DIAGRAM Service Manual YBZ DCI 1 A 1 GB 9 3 9 4 YAZ318...
Страница 37: ...WIRING DIAGRAM 9 4 Service Manual YBZ DCI 1 A 1 GB 9 5 YAZ430...
Страница 38: ...WIRING DIAGRAM Service Manual YBZ DCI 1 A 1 GB 9 5 9 6 Wiring connection between IDU and ODU...
Страница 39: ...WIRING DIAGRAM Service Manual YBZ DCI 1 A 1 GB 10 1 10 REFRIGERATION DIAGRAMS...
Страница 40: ...TUBING CONNECTIONS Service Manual YBZ DCI 1 A 1 GB 11 1 11 TUBING CONNECTIONS...
Страница 70: ...EXPLODED VIEW SPARE PART LIST Service Manual YBZ DCI 1 A 1 GB 15 9 15 9 Exploded view of outdoor unit YBZ214...
Страница 72: ...EXPLODED VIEW SPARE PART LIST Service Manual YBZ DCI 1 A 1 GB 15 11 15 11 Exploded view of outdoor unit YBZ318...
Страница 74: ...EXPLODED VIEW SPARE PART LIST Service Manual YBZ DCI 1 A 1 GB 15 13 15 13 Exploded view of outdoor unit YBZ430...
Страница 76: ...EXPLODED VIEW SPARE PART LIST Service Manual YBZ DCI 1 A 1 GB 15 15 APPENDIX...