EXAMPLE OF CONNECTION REQUIRING ADDITION OF R22
REFRIGERANT
NOTA:
The R22 refrigerant charge value is given for 4 m pipe length .
For longer pipe lengths the amount of charge to be added is 15g/m for each way
15g/m for each way
15g/m for each way
15g/m for each way
15g/m for each way
CIRCUIT A (U1-A)
The additional quantity of R22 will be:
+ 165 g (15m pipe lengths)
being, in this example, an increase of 255 g for circuit A,
and
CIRCUIT B (U2-B / U3-B)
+ 165 g (15 m pipe lengths)
+ 15 g (5 m pipe lengths)
being, in this example, an increase of 180 g for circuit B,
U3-B
U2-B
U1-A
XLM9R
with 5 metres of pipe connections
XLM12R
with 15 metres of pipe connections
XLM9R
with 15 metres of pipe connections
NO
NO
NO
NO
NOTTTTTA :
A :
A :
A :
A :
This operation must only be performed by qualified personnel, in accordance with
refrigeration engineering best practices.
The values in the example of connection for these pipe lengths require the addition of R22
refrigerant on site. Any interventions on the refrigeration circuits must be performed in strict
compliance with CECOMAF GT1-001 recommendations (recommendations on R22
emissions into the atmosphere).