TEMP

1. Air intake grill

2.Air filter

3.Supply air flap

4.Air outlet

5.unit's indicater

6.Horizontal Air flow

   Deflecting louvers

7.On unit's controls

8.Power cord

9.Outdoor unit air intake

10.Power cable

11.control wire

12.Liquid line

13.Suction line

14.drain hose

15.outdoor unit air outlet

16.Remote controls holder

17.Remote control

18.Ionizer (optional)

19.Air purifying filter

20.Electrostatic filter

     (optional)

SYSTEM DESCRIPTION

2

Содержание XLM30RCB

Страница 1: ...TEMP 6 AIR CONDITIONER SPLIT WALL MOUNTED PROGRAMMING AND OPERATION MANUAL INSTALLATION INSTRUCTIONS XLM30 32 RCB GC30 32RCC...

Страница 2: ...tion Selecting The Temperature I FEEL ROOM Temp Function Sleep Function Timer Operation Timer Operating Modes Air Flow velocity and Diretion Adjvstment Turning off theAir Conditioner Current Clock Tim...

Страница 3: ...air conditioning installer observing good refrigeration practice Electrical connections and power cord replacement should only be made by authorized electricians and in accordance with electrical reg...

Страница 4: ...rizontal Air flow Deflecting louvers 7 On unit s controls 8 Power cord 9 Outdoor unit air intake 10 Power cable 11 control wire 12 Liquid line 13 Suction line 14 drain hose 15 outdoor unit air outlet...

Страница 5: ...he temperature control command from the location Remote Control and the unit is done by infra red signal Therefore in using next to you The communication between the Remote Control and the unit is don...

Страница 6: ...OFF directly form the indoor unit display panel without the use of the remote control They are capable of capturing small particles down to 0 1 microns Such as atmospheric and house hold dust coal du...

Страница 7: ...CONTROL BATTERY CHANGE Remove the batteries from the remote control as shown Use two 1 5 volt size AAA batteries For protecting the enviroment please return used batteries for recycling process REMOT...

Страница 8: ...peration F Filter indicator Lights up when air filter requires cleaning G Cooling indicator Lights up only when mode L is pressed H Unit mode button Used to switch the unit for cooling or heating with...

Страница 9: ...ton SLEEP button Vertieal swing button Horizontal swing button Ionizer and FRESH AIR button TIME SET button TIMER button Clear button LCD operation display RM sensor Infrared signal display LOCK Butto...

Страница 10: ...rder to quickly lower the room temperature It will then automatically switch to the low air flow to quietly maintain the selected temperature HEATING OPERATION Select the HEATING mode by pressing MODE...

Страница 11: ...itioner will be turned ON and OFF according to the TIMER setting To cancel the SLEEP function press on one of the following START STOP button 1 SLEEP button 6 Press button 3 to activate the I FEEL fun...

Страница 12: ...EEKEND TIMER OPTIONAL The weekend timers WKT1 and WKT2 can be set for ON and OFF separately for two different time periods for two days only It will be effective on the day of setting and on the day a...

Страница 13: ...on The ON icon ON The ON icon ON time digits will blink time digits will blink 1 Set the ON time at 1 Set the OFF time at 10 30 18 30 2 Press the HOUR 2 Press the HOUR up button to advance up button t...

Страница 14: ...ht Note that the corresponding formerly set timer digits will display without blinking ON time digits will blink time digits blink time digits blink time digits light while OFF icon OFF time digits bl...

Страница 15: ...ressing CLEAR button 12 for 5 seconds will cancel all timer settings and clear timer display The selected timer icon blinks the correspending previous timer ON OFF settings light The selected timer ic...

Страница 16: ...zer I Fresh Air operation optional Pressing the Ionizer I Fresh air key will cycle in the following manner Fresh air option is selectable via switch The function will be kept when mode is switchover F...

Страница 17: ...or when approaching freezing conditions Resumes operation automatically High outdoor temperature Outdoor coil overheating Heating Low outdoor temperature Outdoor coil ice build up Stops outdoor fan an...

Страница 18: ...push the electrostatic filter into the right position 5 close the front panel Note the above procedure is used for cleaning the electrostatic filter PURIFICATION FILTER REPLACEMENT The air purifying f...

Страница 19: ...arted operation will be resumed in the last mode of operation However if the timer was used the unit will be turned off by the timer only if the remote control is aimed at the unit Otherwise the power...

Страница 20: ...he air conditioner Do not insert any objects in the air outlet of the indoor or outdoor unit Do not splash water on air conditioner IF NOISE IS HEARD There may be hissing sound during operation or jus...

Страница 21: ...ot respond properly to remote control command IR signal does not reach unit Distance between remote control and unit too large or aimed at from improper angle IR receiver on unit exposed to strong lig...

Страница 22: ...DOOR UNITS 3 ELECTRICAL REQUIREMENTS 4 INSTALLATION OF THE INDOOR UNIT 5 CONDENSATE HOSE CONNECTION 6 ELECTRICAL CONNECTIONS BETWEEN INDOOR AND OUTDOOR UNITS 7 REFRIGERANT TUBING 8 FINAL TASKS INSTALL...

Страница 23: ...ise or exhaust air 5 Place the mounting pads under the unit legs 6 Install the outdoor unit as shown Refer to the technical and service 7 When the unit is installed on a wall install the drain connect...

Страница 24: ...200 mm min 150 mm min 100 mm min 100 mm min 400 mm min 100 mm min Fig 3 Fig 3 1 To attach 2 To remove Fig 4 Fig 4 1 Mounting pads x4 TEMP 2300 mm min 1 500 mm min 100 mm min...

Страница 25: ...indoor unit press on the upper part of the panel and at the same time push the bottom toward the indoor unit 7 Replace the screws and their caps Fig 5 1 Lift front panel 2 Screw caps 3 Screw 4 Horizon...

Страница 26: ...nsure that the condensate drain hose is at all points in a downward slope manner 4 When installing the drain hose avoid traps and U bends The end of the drain hose should not be immersed in water 5 Fo...

Страница 27: ...e 4 Indoor unit 5 Power supply 6 Electrical interconnecting cable 7 Terminal board male female Important Wire size should be according to local electrical codes and regulation Twin wire cable 2 wires...

Страница 28: ...ION OF THE REFRIGERATION TUBES AND THE INDOOR UNIT After connecting the unions of the indoor and outdoor units purge the air from the tubes and indoor unit as follows 1 Connect the charging hoses with...

Страница 29: ...lve caps and ensure that they are tightened properly 2 Fill gaps on the wall between hole sides and tubing with sealer 3 Attach wiring and tubing to the wall with clamps where necessary 4 Operate the...

Страница 30: ...IDE Offices on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3...

Отзывы: