No.0010562727

Installation Manual of Room Air Conditioner

Drawing for the installation of indoor and outdoor units

Read this manual before installation

1.Driver

2.Hacksaw

3.Hole core drill

4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)

6.Pipe cutter

7.Flaring tool

8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or 

     soap-and-water solution

11.Measuring tape

Explain sufficiently the operating means to the user

according to this manual.

Necessary Tools for Installation

The models adopt HFC free refrigerant R410A

A

B
C

D

E
F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain-elbow

1

1

2

3

4

5

6

2

1

4

1

1

Number

    of

articles

Accessory parts

Pipe supporting plate

Arrangement of piping directions

Rear left

Rear 

right

Left

Below

Right

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be

more than 2m.

A

G

Attention must be paid to 

the rising up of drain hose

more than 5cm

more than 10cm

more than 10cm

more than 10cm

more than 60cm

more than 15cm

more than 10cm

A

C

D

Screw

Plastic cap

4X25

Содержание HSU-09RE03

Страница 1: ...parts for piping Mark Parts name Non adhesive tape Adhesive tape Saddle L S with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover No Ac...

Страница 2: ...the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not...

Страница 3: ...ter installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor side Wall hole 60mm Indoor unit 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the m...

Страница 4: ...ain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall h...

Страница 5: ...e terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by th...

Страница 6: ...sands etc shall not enter the pipe The standard pipe length is 5m If it is over 5m the function of the unit will be affected If the pipe has to be lengthened the refrigerant should be charged accordin...

Страница 7: ...il hitting lightly To prevent the gas leakage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increases suddenly After attachi...

Страница 8: ...rried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drain...

Отзывы: