21
TH 3067
X 1100/X 1900
INTERCONNECTIONS WITH OUTDOOR UNIT • Model AR
* VS : Standard ventilation - PV : High ventilation
*
THREE PHASE 230 V : Installation regulated in France.
**
IMPORTANT
: These values are for information only, they should be checked and selected to comply with local and/
or national codes and regulations. They are also subject to the type of installation and to the type of cables.
INTERCONNECTIONS WITH REMOTE CONTROL • TRANSFORMER
ELECTRICAL SPECIFICATIONS
Main power supply
TRANSFORMER (Not suppIied)
for power supply 3~400 V + Earth, without neutral
Models
AO
AR
Nominal power input
single phase
transformer
400 V / 230 V in VA
VS
630
1000
FV
X 1100
1000
1000
X 1900
1600
1600
Unit type
Model X 1100
Model X 1900
Power supply
3 ~230 V* - 50 Hz
3N ~400 V - 50 Hz
3 ~230 V* - 50 Hz
3N ~400 V - 50 Hz
Models
AR
AO
AR
AO
AR
AO
AR
AO
C Ventilation(VS/FV)*
- Nominal power input
- Nominal intensity
- Maximum intensity
- Starting intensity
- Motor fuse rating
- Cable size
kW
A
A
A
A
mm
2
4,2/4,4
14,8/15,5
22/23
60/61
25
4 x 2,5
3,8/4
12,1/12,8
18/19
58/59
20
4 x 2,5
4,2/4,4
9,7/10,4
13/14
38/39
16
5 x 1,5
3,8/4
7,8/8,5
11/12
37/38
12
5 x 1,5
6,7/7,2
21,6/23,9
33/36
106/110
40
4 x 6
5,5/6
17,8/20,1
28/31
103/107
32
4 x 4
6,7/7,2
14,1/16,4
21/24
60/64
25
5 x 2,5
5,5/6
11,2/13,5
17/20
57/61
20
5 x 2,5
Electrical heating
+ Ventilation (VS/FV)
- Nominal power input
- Nominal intensity
- Maximum intensity
- Starting intensity
- Motor fuse rating
- Cable size
kW
A
A
A
A
mm
2
9,4/9,6
25,5/26,2
30/31
60/61
32
4 x 4
9,4/9,6
25,5/26,2
30/31
58/59
32
4 x 4
9,4/9,6
15,5/16,2
19/20
38/39
20
5 x 2,5
9,4/9,6
15,5/16,2
19/20
37/38
20
5 x 2,5
12,5/13
33,7/34,2
40/43
106/110
40/45
4 x 10
12,5/13
33,7/34,2
40/43
103/107
40/45
4 x 10
12,5/13
20,4/20,9
24/27
60/64
25/32
5 x 4
12,5/13
20,4/20,9
24/27
57/61
25/32
5 x 4
Ventilation (VS/FV)
- Nominal power input
- Nominal intensity
- Maximum intensity
- Starting intensity
- Motor fuse rating
- Cable size
kW
A
A
A
A
mm
2
13,2/13,4
38,4/39,1
49/50
87/88
50
4 x 10
12,8/13
35,7/36,4
45/46
85/86
45
4 x 6
13,2/13,4
23,3/24
29/30
54/55
32
5 x 4
12,8/13
21,4/22,1
27/28
53/54
32
5 x 4
18,7/19,2
53,1/55,4
70/73
142/145
80
4 x 16
17,5/18
49,3/51,6
64/67
140/143
80
4 x 16
18,7/19,2
32,3/34,6
42/45
81/84
45
5 x 10
17,5/18
29,4/31,7
38/41
78/81
40/45
5 x 10
Unit type
Model X 1100
Model X 1900
Power supply
3 ~ 230 V* - 50 Hz3N ~ 400 V - 50 Hz3 ~ 230 V* - 50 Hz3N ~ 400 V - 50 Hz
Outdoor unit
- Nominal power input
- Nominal intensity
- Maximum intensity
- Starting intensity
- Cable size
kW
A
A
A
mm
2
~ 230 V - 50 Hz
160
0,9
1
1,5
5 x 1,5
~ 230 V - 50 Hz
160
0,9
1
1,5
5 x 1,5
~ 230 V - 50 Hz
295
1,6
2
3
5 x 1,5
~ 230 V - 50 Hz
295
1,6
2
3
5 x 1,5
INTERCONNECTION WITH REMOTE CONTROL
Unit type
Model
X 1100
Model
X 1900
ventilation (VS/FV)
- Nominal intensity
- Maximum intensity
- Starting intensity
- Cable size
A
A
A
mm
2
2,1/2,8
3/4
4/5
4 x 1,5
2,4/4,7
3/6
5/9
4 x 1,5
ventilation (VS/FV)
- Nominal intensity
- Maximum intensity
- Starting intensity
- Cable size
A
A
A
mm
2
2,1/2,8
3/4
4/5
5 x 1,5
2,4/4,7
3/6
5/9
54 x 1,5
+ Electrical heating