5-2
PERFORMANCE DATA
SM TRIO52 1-A.2 GB
5.1.3
Heating Capacity (kW) - Run Mode
230[V] : Indoor Fan at High Speed.
ID COIL ENTERING AIR DB TEMPERATURE [C
0
]
OD COIL ENTERING
AIR DB/WB
TEMPERATURE [C
0
]
DATA
15
20
25
-15/-16
TC
3.52
3.30
3.08
PI
1.15
1.32
1.48
-10/-12
TC
4.21
3.99
3.78
PI
1.33
1.49
1.66
-7/-8
TC
4.73
4.52
4.30
PI
1.46
1.62
1.79
-1/-2
TC
5.00
4.78
4.56
PI
1.52
1.69
1.86
2/1
TC
5.17
4.95
4.73
PI
1.57
1.73
1.90
7/6
TC
6.82
6.60
6.38
PI
1.63
1.80
1.97
10/9
TC
7.09
6.87
6.65
PI
1.71
1.88
2.04
15/12
TC
7.36
7.14
6.92
PI
1.79
1.95
2.12
15-24
TC
85 - 105 % of nominal
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TC –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.1.4
Capacity Correction Factors
Heating Capacity Ratio Vs. Outdoor Temperature
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
-15
-10
-5
0
5
10
15
Outdoor WB Temperature [deg C]
Capaci
ty Rati
o
CONTENTS