3
2
1
1
1
3
1
5
6
7
8
9
4
14
13
15
11
1
12
1
1
1
1
1
1
HW
CW
7
General Hydraulic Layout for a Type 2 (*) Installation
Layout 2 :
This layout is recommended for heating installations with wide operating water flow variations (radiator thermostatic valves present in the system). We strongly
recommend including the buffer tank
(2)
as it guarantees that the heating loop capacity is higher than the minimum volume when the maximum number of
thermostatic valves are closed.
The flow adjustment valve
(11)
is used to balance the flow in heating mode and domestic hot water mode to always ensure optimum PAC HT operation.
1
Stop valve
11
Flow regulating valve
2
Buffer tank (optional)
12
Expansion tank
3
Filter or sludge trap
13
In-line heater
4
Relief valve
14
Bleed
5
3-way valve - Domestic hot water
15
Safety valve
6
Domestic hot water tank
HW : Hot Water
7
Safety devices
CW : Cold Water
8
Recycling circulating pump (optional)
*
Installation components not supplied
9
Circulation pump
Содержание PAC HT 12-6