background image

CE

All the products are in conformity with the following
European provision:
-Low voltage Directive
-Electomagnetic CompatibilitY

ROHS

 Your air conditioning product is marked with this

    symbol.This means that electrical and electronic
    products shall not be mixed with unsorted
    household waste.Do not try to dismantle the
    system yourself:the dismantling of the air

conditioning system,treatment of the refrigerant,of oil and of
other part must be done by a qualified installer in accordance
with relevant local and national legislation.Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery.By ensuring this product is disposed
of correctly,you will help to prevent potential negative cons-
equences for the environment and humen health.Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and
nationl legislation.

The products are fulfilled with the requirements in the
directive 2011/65/EU  of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment(EU
RoHS Directive)

WEEE

In accordance with the directive 2012/19/EU of the European
parliament,herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.

DISPOSAL REQUIREMENTS:

Contains fluorinated greenhouse gases

 covered by the Kyoto Protocol

This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol.Do not vent into the atmosphere.
Refrigerant type:R410A
GWP

2088

:

 

GWP=global warming potential
Please fill in with indelible ink,

1      the factory refrigerant charge of the product
2      the additional refrigerant amount charged in the field

            and

 on the refrigerant charge label supplied with the product.

 

 The filled out label muset be adhered in the proximity of the

 

 product charging port(e.g.onto the inside of the stop value

 

 cover).
 A contains fluorinated greenhouse gases covered by the

 

 Kyoto Protocol
 B fatory refrigerant charge of the product:see unit name

 

 plate
 C additional refrigerant amount charged in the field
 D total refrigerant charge
 E outdoor unit
 F refrigerant cylinder and manifold for charging

A

B

C

D

kg

kg

kg

R410A

EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS

IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED

1+2  the total refrigerant charge

Содержание AW-YSDM048-H11

Страница 1: ...before installation Keep this operation manual for future reference Contents Safety Precautions Read Before Installation Name of Parts Installation Procedure Troubleshootingve and Move and scrap the a...

Страница 2: ...ction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment EU RoHS Directive WEEE In accordance with the directive 2012 19 EU of the European parliament herewith we inform...

Страница 3: ...UCTIONS These information can ensure the correct operation of the machine After a long time use of air conditioner the base should be checked for any damages If the damaged base is not repaired the un...

Страница 4: ...moke or fire Only use refrigerant R410A as indicated on the unit when installing or relocating the unit The use of any other refrigerant or an introduction of air into the unit circuit may cause the u...

Страница 5: ...e a charging cylinder The use of charging cylinder will change the composition of the refrigerant and lead to power loss Exercise special care when handling the tools An introduction of foreign object...

Страница 6: ...Tear up the plastic bags before disposing of them to prevent accidents Properly dispose of the packing materials Do not touch the refrigerant pipes with bare hands during and immediately after operati...

Страница 7: ...Refrigerant charging Vacuum Gauze Checking vacuum degree Tools Materials Use Notes Charging Cylinder Refrigerant Charging Must not be used with R410 type units CAUTION Items to Be Checked 1 Verify the...

Страница 8: ...tightness If a clutch type flare tool is used to machine flares on units that use R410A make the protruding part of the pipe between 1 0 and 1 5mm Copper pipe gauge for adjusting the length of pipe pr...

Страница 9: ...il from flowing back into the refrigerant circuit when the vacuum pump power is turned off power failure It is also possible to attach a check valve to the actual vacuum pump afterwards Standard degre...

Страница 10: ...where obstacles do not exist near the air inlet and air outlet Place where the air outlet may not be exposed to a strong wind Place surrounded at four sides are not suitable for installation A 1m or...

Страница 11: ...areas or other places with salty atmosphere of sulfate gas corrosion may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which...

Страница 12: ...ng information 2 Installation of outdoor unit Give enough room for the concrete foundation to fix by anchor bolts Place the concrete foundation deep enough Install the unit so that the angle of inclin...

Страница 13: ...not to let foreign matters such as sands enter the pipe 4 Piping connection method Forced fastening without centering may damage the threads and cause a gas leakage Model One way piping length Vertica...

Страница 14: ...kage will be found 3 Pressurize for about 24 hours at 3 0MPa 30 kg cm 2 g A small leakage will be found Air Tightness Test When pressurizing for 24 hours a variation of 1 C in the ambient temperature...

Страница 15: ...the inspection of gas leakge No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed the step 6 If it does not stop gas leakage discharge whole refrigerant...

Страница 16: ...able and connecting cable should be self provided All the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that...

Страница 17: ...RE TO EXECUTE OFF OPERATION BEFORE ELECTRIC POWER IS DISCONNECTED FOR SERVICING This unit has a function of automatic restart system after recovering power stoppage 1 Before starting test run for all...

Страница 18: ...Troubleshooting 18...

Страница 19: ...itioning the content of lead mercury hexavalent chromium polybrominated biphenyls and polybrominated diphenyl ethers are not more than 0 1 mass fraction and cadmium is not more than 0 01 mass fraction...

Страница 20: ......

Отзывы: