(a) Minimum cable section AWG18 (0.75mm
2
).
(b) The thermistor and connection wire (10m) are delivered with the domestic hot water tank (T5) or zone 2 outlet temp. (Tw2)
(c) See
9.7.4 Specifications of standard wiring components
1
2
3
4
5
9
10/11/23
12
13
15
Description
AC/DC
Required number of conductors
Maximum running current
Item
DHW pump control cable
3-way valve control cable
Thermistor cable for T5
Booster heater control cable
Power supply cable for unit
Thermistor cable for Tw2
Boiler control cable
Room thermostat cable
User interface cable
Solar energy kit signal cable
AC
2
200mA
AC
5
200mA
AC
2 or 3
200mA(a)
/
2
200mA
DC
2
(b)
AC
2
200mA(a)
200mA(a)
AC
2 or 3
DC
2
(b)
(c)
AC
2
200mA(a)
AC
3+GND
A
B
C
D
E
F
G
H
Assembly unit
Coding
P_s: Solar pump (field supply)
P_c: Circulation pump / zone 2 pump (field supply)
P_o: Outside circulation pump / zone 1 pump (field supply)
Boiler (field supply)
Room thermostat (field supply)
User interface
Solar energy kit (field supply)
Outdoor unit
Assembly unit
Coding
I
J
K
L
M
N
O
P
Contactor
Power supply
Booster heater
Domestic hot water tank
SV1: 3-way valve for domestic hot
water tank (field supply)
SV2: 3-way valve (field supply)
P_d: DHW pump (field supply)
Zone2 SV3(3-way valve)