77
14 TECHNICAL SPECIFICATIONS
14.1 General
14.2 Electrical specifications
Refer to the Technical Data
Connections
Expansion vessel
Pump
Operation range - water side
Operation range - air side
Weight
Nominal capacity
Dimensions HxWxD
Net weight
Gross weight
water inlet/outlet
Water drain
volume
Maximum working
pressure (MWP)
Type
Internal water volume
Pressure relief valve
water circuit
heating
cooling
heating
cooling
domestic hot water by
heat pump
1-phase
4/6 kW
792×1295×429mm
98kg
121kg
G1"BSP
8L
8 bar
water cooled
3.2L
1-phase
8/10 kW
945×1385×526mm
G5/4"BSP
hose nipple
water cooled
3.2L
3 bar
+12~+65°C
+5~+25°C
-25~35°C
-5~43°C
-25~43°C
1-phase
12/14/16 kW
945×1385×526mm
G5/4"BSP
water cooled
2.0L
1-phase 4/6/8/10/12/14/16kW
3-phase 12/14/16kW
Standard unit (power supply via unit)
Power Supply
Nominal Running Current
220-240V~ 50Hz
380-415V 3N~ 50Hz
Backup heater
Power Supply
Nominal Running Current
See "9.7.5 Connection of the backup heater power supply"
See "9.7.4 Specifications of standard wiring components"
149kg
175kg
3-phase
12/14/16 kW
945×1385×526mm
G5/4"BSP
126kg
153kg
165kg
193kg
water cooled
2.0L
No. of speed
Variable speed
Variable speed
Variable speed
Variable speed