TROUBLESHOOTING
HKD DCI 49 Version - 1
10.2.10 Inverter compressor drive error diagnosis and solution (P4)
Error Code
P4
Malfunction decision
conditions
An abnormal inverter compressor drive is detected by a special
detection circuit, including communication signal detection,
voltage detection, compressor rotation speed signal detection
and so on.
Supposed causes
●
Wiring mistake
●
IPM malfunction
●
Outdoor fan ass’y faulty
●
Compressor malfunction
●
Outdoor PCB faulty
Trouble shooting:
Check the wiring between main PCB
and compressor
Correct the connection or replace
the wires and connectors.
Yes
No
Check the IPM
No
Yes
Replace the IPM board or replace
the main PCB
Check the outdoor fan and the
outdoor unit ventilation
No
Please refer to the solution of
【
Fan
Speed Has Been Out Of Control
】
malfunction
Yes
Check the compressor resistance
values
No
Replace the compressor.
Yes
Replace the outdoor main PCB
Содержание 7SP023054
Страница 12: ...DIMENSION Version 1 12 HKD DCI For AWSI HKD009 N11 For AWSI HKD012 N11 For AWSI HKD018 N11...
Страница 13: ...DIMENSION HKD DCI 13 Version 1 For AWSI HKD024 N11...
Страница 58: ...EXPLODED VIEW AND SPARE PART LIST Version 1 58 HKD DCI 11 5 Exploded view of model AWSI HKD024 N11...
Страница 59: ...EXPLODED VIEW AND SPARE PART LIST HKD DCI 59 Version 1...
Страница 64: ...EXPLODED VIEW AND SPARE PART LIST Version 1 64 HKD DCI 11 10 Exploded view of model AWAU YKD018 H11...
Страница 65: ...EXPLODED VIEW AND SPARE PART LIST HKD DCI 65 Version 1...
Страница 67: ...EXPLODED VIEW AND SPARE PART LIST HKD DCI 67 Version 1 11 12 Exploded view of model AWAU YKD024 H11...
Страница 69: ...HKD DCI 69 Version 1 SERVICE MANUAL HKD DCI Series...