background image

  

SS

300

AT

C

60

 

Installation

 

Guide

 

Chapter

 

3

 

SS

300

AT

C

60

 

Overview

 

This

 

chapter

 

provides

 

an

 

overview

 

of

 

the

 

SS

300

AT

C

60

 

and

 

describes

 

in

 

detail

 

about

 

the

 

following.

 

• 

Front

 

panel

 

of

 

SS

300

AT

C

60

  

• 

Rear

 

panel

 

of

 

SS

300

AT

C

60

  

 

SS

300

AT

C

60

 

is

 

a

 

802.11n

 

access

 

point/sensor

 

device

 

with

 

a

 

Cisco

 

compatible

 

console

 

port.

 

It

 

has

 

five

 

external

 

antenna

 

ports

‐ 

three

 

at

 

the

 

top

 

and

 

two

 

at

 

the

 

bottom.

 

It

 

is

 

a

 

dual

 

radio

 

device

 

capable

 

of

 

acting

 

as

 

an

 

access

 

point

 

or

 

a

 

sensor.

 

The

 

top

 

three

 

antennas

 

are

 

for

 

radio1

 

and

 

the

 

bottom

 

two

 

antennas

 

are

 

for

 

radio2.

 

The

 

front

 

panel

 

of

 

the

 

SS

300

AT

C

60

 

has

 

LEDs

 

that

 

indicate

 

the

 

working

 

of

 

the

 

device.

 

 

Figure  2. Front Panel of SS-300-AT-C-60 

Note

:

  

LED5,

 

that

 

is

 

not

 

visible

 

in

 

the

 

zoomed

in

 

view

 

in

 

the

 

above

 

figure,

 

is

 

not

 

in

 

use.

 

Only

 

LED1,

 

LED2,

 

LED3

 

and

 

LED4

 

are

 

in

 

use.

 

The

 

following

 

table

 

indicates

 

various

 

device

 

states

 

using

 

the

 

LEDs

 

on

 

the

 

device,

 

when

 

the

 

device

 

is

 

in

 

AP

 

mode.

 

Table 1. 

LED details for SS-300-AT-C-60 in AP mode 

 

LED1 or

 

Power

 

LED2 or

 

WLAN1

 

LED3 or

 

WLAN2

 

LED4 or

 

LAN

 

Description

 

Solid Green 

Any 

Any 

Solid Green 

The AP is receiving power and is working 
normally. The AP is connected to the Server.  

Solid Green 

Off 

Slow Blink 

Slow Blink 

The AP upgrade is in progress. 

Solid Orange 

Any 

Any 

Solid Green 

The AP is unable to get Ethernet link. 

Solid Orange 

Any 

Any 

Fast Blink 

The AP did not receive a valid IP address via the 
DHCP.  

Solid Orange 

Any 

Any 

Slow Blink 

The AP is unable to connect to the Server. 

Off 

Off 

Off 

Off 

The AP is not powered on or it is in the process 
of starting up. 

 

WLAN1

 

and

 

WLAN2

 

LEDs

 

will

 

blink

 

when

 

there

 

is

 

activity

 

on

 

the

 

respective

 

radios.

 

 

The

 

following

 

table

 

indicates

 

various

 

device

 

states

 

using

 

the

 

LEDs

 

on

 

the

 

device,

 

when

 

the

 

device

 

is

 

in

 

sensor

 

mode.

 

Содержание SS-300-AT-C-60

Страница 1: ...Tight Networks Inc 339 N Bernardo Avenue 200 Mountain View CA 94043 http www airtightnetworks com Product documentation is being enhanced continuously based on customer feedback To obtain a latest cop...

Страница 2: ...This page has been intentionally left blank...

Страница 3: ...SS 300 AT C 60 Access Point Sensor InstallationGuide...

Страница 4: ...FOR ANY DAMAGE OR VIOLATION OF GOVERNMENT REGULATIONS ARISING FROM YOUR USAGE OF THE PRODUCT EXPECT AS EXPRESSLY DEFINED IN THE INDEMNITY SECTION OF THIS DOCUMENT LIMITATION OF LIABILITY AirTight wil...

Страница 5: ...llowing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RF exposure wa...

Страница 6: ...conditions d exposition des appareils mobiles les antennes se situent moins de 20 cm du corps d une personne FCC NOTICE To comply with FCC part 15 rules in the United States the system must be profess...

Страница 7: ...SS 300 AT C 60 with power adapter 10 CHAPTER 5 MANUALLY CONFIGURING THE SS 300 AT C 60 AS SENSOR 12 5 1 INTRODUCTION 12 5 2 CONFIGURING SENSOR THROUGH CONFIG SHELL 12 5 2 1 Invoke HyperTerminal or min...

Страница 8: ...E SENSOR 9 FIGURE 9 HOLES FOR INSERTING SCREWS 9 FIGURE 10 POWER UP AND CONNECT SS 300 AT C 60 USING POE 10 FIGURE 11 POWER UP SS 300 AT C 60 10 FIGURE 12 CONNECT SS 300 AT C 60 TO THE NETWORK 11 FIGU...

Страница 9: ...rs Package Contents Lists the components included in the system package SS 300 AT C 60 Overview Provides an overview of sensor Installing the device Describes how to connect and install SS 300 AT C 60...

Страница 10: ...on how it is configured Please ensure that the following items are included in the SS 300 AT C 60 device package If the package is not complete please contact AirTight Networks Inc Technical Support a...

Страница 11: ...e Only LED1 LED2 LED3 and LED4 are in use The following table indicates various device states using the LEDs on the device when the device is in AP mode Table 1 LED details for SS 300 AT C 60 in AP mo...

Страница 12: ...link Slow Blink The Sensor upgrade is in progress Solid Orange Any Any Solid Green The Sensor is unable to get Ethernet link Solid Orange Any Any Fast Blink The Sensor did not receive a valid IP addre...

Страница 13: ...02 3af standard Figure 3 Rear Panel of SS 300 AT C 60 Table 4 Rear Panel Port Settings for SS 300 AT C 60 Port Description Connector Type Speed Protocol Ethernet LAN1 This enables the device to be con...

Страница 14: ...to the default wifi security server All the VLAN configurations are lost Device mode is changed to Sensor Only If static IP was configured on the device the IP is erased and DHCP mode is set After re...

Страница 15: ...ported if the following conditions are satisfied The device is in Sensor mode A DNS entry wifi security server is set up on all DNS Servers This entry should point to the IP address of the Server By d...

Страница 16: ...t in the same position as shown above Clip the metal ceiling bracket to a suitably located ceiling tile separator Figure 6 Clipping the Metal Ceiling bracket Slide the movable section into place and t...

Страница 17: ...serting screws Connect the Ethernet cable for power and network connection to the LAN port on the back of the device To mount the SS 300 AT C 60 device onto the mounting bracket insert the mounting br...

Страница 18: ...e 10 Power up and connect SS 300 AT C 60 using PoE 4 2 4 Using SS 300 AT C 60 with power adapter To power up the device perform the following steps 1 Plug the power cable into the DC power receptacle...

Страница 19: ...ensor list command You will see a list of all Sensors that are recognized by the SpectraGuard Enterprise server The Sensor is configured and ready to go Check the Console to ensure that this Sensor ha...

Страница 20: ...llations Sensor is placed on a subnet that is not DHCP enabled 5 2 Configuring Sensor through Config Shell To use the Config Shell connect a Serial RS 232 cable between your computer and the Sensor Th...

Страница 21: ...ide Figure 14 Opening HyperTerminal Note If you are using a Linux laptop you can use minicom to connect to the Config Shell 5 2 1 2 Defining a New HyperTerminal Connection Figure 15 Define a New Hyper...

Страница 22: ...n the Connection Description dialog 5 2 1 3 Specifying HyperTerminal Connection Details Figure 16 Specify HyperTerminal Connection Details Select or enter the appropriate connection details Click OK o...

Страница 23: ...iguration in the Spectraguard Enterprise User Guide for more details Recommended AirTight recommends that you change the default password for security reasons although it is not mandatory 5 2 3 Set Se...

Страница 24: ...set mode command to set the device mode for SS 300 AT C 60 Figure 19 set sensor mode command for SS 300 AT C 60 5 2 5 Configure Network Settings Once the mode is set you have to enable the Network Set...

Страница 25: ...ays the Server discovery setting information get status Displays the current running status of all the components get version Displays the version and build information of all the components get vlan...

Страница 26: ...n 10 and 127 as the shared secret The string is internally converted to hexadecimal format It can be used instead of the set communication key command Table 3 Miscellaneous commands Other Commands Com...

Страница 27: ...sure that the traffic is allowed on UDP port 3851 If utilizing the Server ID based discovery ensure that multicast is enabled on the network Alternatively if utilizing the Server IP based discovery en...

Страница 28: ...ng the Server IP based discovery ensure that the DNS name wifi security server has been correctly entered on the DNS Server Also ensure that the DNS Server IP addresses are either correctly configured...

Страница 29: ...ecret The CLI commands are provided on both Server and Sensor for changing the shared secret Note Once the shared secret communication key is changed on the Server all Sensors connected to the Server...

Отзывы: