MAINTENANCE INSTRUCTIONS

For safety, before cleaning, disconnect the device from the power.

It is forbidden to open the service grille (risk of electric shock and trapping in 

the fans). Repairs must be carried out exclusively by authorized personnel.

The interior of the device must not be cleaned with water or steam.

Exterior cleaning

It is recommended to clean the intake grille with a damp cloth� Cleaning must be done with the 

unit  off;  the  mixture  of  dust  and  moisture  generates  a  paste  that  could  enter  and  affect  the

 

internal components, rendering them unusable before the estimated deadline� 

An annual cleaning of the discharge area should be performed��

Cleaning of the unit casing should be done with a damp cloth and conventional detergent, 

Do not use corrosive, caustic or acid-containing detergents�

The intake grille prevents objects from entering the internal elements� It is convenient 

periodically check that the intake grille is free of any object that could prevent the entry of air (papers, plas-

tics, etc�)� 

Interior cleaning

In models with perforated grille, it is advisable to clean the inside of the unit with 

a  vacuum  cleaner,  at  least  once  every  two  years  (*),  and  by  qualified  personnel.

 

(*) This period of time is indicative, it depends on the conditions of each installation� 

In places with a high number of suspended particles (a lot of dust and dirt) it is desirable 

increase the frequency of interior cleaning.

Содержание K7 770 HEPA

Страница 1: ...tallation Give this manual to the end user SAFETY WARNING SYMBOLS Attention danger warning of security Danger Danger of injury Attention Do not get under the load High weight Important information INS...

Страница 2: ...D STORAGE 4 OPERATING INSTRUCTIONS 4 Power supply 4 Autoregulation 4 Fixings 4 ELECTRICAL SCHEMES 5 DATASHEET 6 DATASHEET 7 MAINTENANCE INSTRUCTIONS 8 REPAIRS AND REPLACEMENTS 9 ACCESSORIES 12 FAULTS...

Страница 3: ...ol a specific manual is attached that must be used for its installation and operation It is necessary to remove the service grill to connect the equipment The electrical connection is made in an IP bo...

Страница 4: ...dicates that dirty filters should be replaced with clean ones Furthermore the team cannot guarantee that the flow and consequently the renewals hour will be maintained until clean filters are installe...

Страница 5: ...TRICOS DE UNIDADES DE VENTILACI N de WIRING DIAGRAMS OF VENTILATI N UNITS Page of K7 770 HEPA Caudal constante Regulaci n fija PE N L PE N L Amarillo verde Azul Negro Q 3 230Vx1 50Hz Caja de conexione...

Страница 6: ...res bacteria viruses and fine particles PM10 PM2 5 and PM1 Self supporting galvanized steel frame prepared for recessed installation in false cei lings Easy access log panel for filter replacement Suc...

Страница 7: ...HEPA 7 DATASHEET Operation infographic Maintenance Air purified outlet Air inlet Indicator Filter change Service panel Service door for filters Threaded knob to adjust the position of the filters insi...

Страница 8: ...deadline An annual cleaning of the discharge area should be performed Cleaning of the unit casing should be done with a damp cloth and conventional detergent Do not use corrosive caustic or acid conta...

Страница 9: ...ese instructions Before carrying out any repairs you must Notify staff and indicate that work is in progress Disconnect the current and protect the thermal magnet so that no one can actuate it by acci...

Страница 10: ...filters under normal operating conditions is Prefilter G4 500 hours Compact filter F7 1000 hours Absolut filter H14 3500 hours It is recommended to check the condition of the filters every six months...

Страница 11: ...the current make sure that there is no voltage and the turbine does not rotate Open the service panel as indicated in the previous section The new fan is installed following the above procedure in re...

Страница 12: ...manual Purifier K7 770 HEPA 12 ACCESSORIES Supports and shock absorbers according to installation see references in attached document Standard cable clamp Silentblock in angle Silentblock rod damper R...

Страница 13: ...hes the equipment and if not check the power cables 3 1 If the equipment has voltage but the fan does not rotate check if there is 5 5V in continuous between the yellow and black cables 3 2 In case th...

Страница 14: ...e s directiva s Low Voltage Directive 2014 35 UE Directiva Baja Tensi n 2014 35 UE Electromagnetic Compatibility Directive 2014 30 UE Directiva Compatibilidad Electromagn tica 2014 30 UE Restriction C...

Страница 15: ...istics flow rate technical data of the fans It is essential to have this number to provide possible spa re parts or technical information on the purifier in question In case of detecting errors or amb...

Страница 16: ...Pla de la Bruguera E 08211 Castellar del Vall s Barcelona Spain 34 93 715 99 88 airtecnics airtecnics com www airtecnics com WELDOM10025 R0 17 09 21 We reserve the right to change design and specifica...

Отзывы: