background image

Instruction manual - Purifier

K7 770 HEPA

15

WARRANTY

LThe warranty extends for one calendar year from the date of delivery� The guarantee is limited to repairing 

or replacing from our warehouse the products that eventually suffer breakdowns attributable to production 

defects� Installation costs are borne by the buyer� Products that in our opinion have been used improperly, 

handled incorrectly, improperly installed, connected to voltages other than the nominal, modified or repaired 

by unauthorized personnel, or that have suffered damage during transport, are excluded from any guarantee.

For the validity of this guarantee, it will be essential that it be correctly completed and accompanied by 

the invoice that proves the date of purchase. In the case of being tampered with, it will lose its validity. 

It is the sole responsibility of the buyer to take the necessary security measures so that, in the event of a failure of one of the products, 

no damage occurs to third-party equipment, facilities or people.

Warranty card

All air purifiers are identified by a unique serial number printed on a label 

located on the inside of the service door. It also indicates the purifier mo

-

del and its technical characteristics (flow rate, technical data of the fans).

 

It is essential to have this number to provide possible spa-

re  parts  or  technical  information  on  the  purifier  in  question.

 

In case of detecting errors or ambiguities in this manual, con-

tact Airtècnics to resolve it and improve the documentation� 

Airtècnics reserves the right to change any of the specifications in this 

manual�

Purificator data: 

Buyer data:

Seller data:

Model:

Name:

Name:

Serial number:

Country:

Country:

Invoice date:

Adress:

Adress:

Invoice number:

Telephone:

Telephone:

Fax:

Fax:

Seal and sign from the buyer

Seal and sign from the seller

If you detect any errors in this manual, we will be happy to receive your comments, it helps us to continue improving. Airtècnics 

reserves the right to modify any of the specifications in this manual.

....................................................

..............................................................................................................................................

...............................................................................................................................................

......................................

...............................

...............................

..........................................

............................................................................................................................................

.............................................................................................................................................

.....................................

................................

..................................

...........................

...........................

IDENTIFICATOR

Conca de Barbera 6 - Pla de la Bruguera

08211 Castellar del Vallès - BCN (SPAIN)

Tel +34 93 7159988 www.airtecnics.com

K7 770 A FC+H14

Model:
Code:

AIRWEL70105

Dimensions:

Motor:

Tension:

220

V

Frequency:

50

Hz

Intensity:

A

0,68

Power:

0,061

kW

Fan:

rpm

Speed:

Capacitor:

microF

Air Volume:

m3/h

Filter:

Pre-Filter:

Filter:

Customer:

405.072

EXPROT

4421 V

Serial nº:

Order nº:

18

Fab nº:

Before use observe security rules and operating instructions!
Avant la mise en service, observer les prescriptions de

sécurité et le manuel d'utilisation !

¡Antes de su puesta en marcha consultar el manual de

instrucciones y normas de seguridad!

300

Содержание K7 770 HEPA

Страница 1: ...tallation Give this manual to the end user SAFETY WARNING SYMBOLS Attention danger warning of security Danger Danger of injury Attention Do not get under the load High weight Important information INS...

Страница 2: ...D STORAGE 4 OPERATING INSTRUCTIONS 4 Power supply 4 Autoregulation 4 Fixings 4 ELECTRICAL SCHEMES 5 DATASHEET 6 DATASHEET 7 MAINTENANCE INSTRUCTIONS 8 REPAIRS AND REPLACEMENTS 9 ACCESSORIES 12 FAULTS...

Страница 3: ...ol a specific manual is attached that must be used for its installation and operation It is necessary to remove the service grill to connect the equipment The electrical connection is made in an IP bo...

Страница 4: ...dicates that dirty filters should be replaced with clean ones Furthermore the team cannot guarantee that the flow and consequently the renewals hour will be maintained until clean filters are installe...

Страница 5: ...TRICOS DE UNIDADES DE VENTILACI N de WIRING DIAGRAMS OF VENTILATI N UNITS Page of K7 770 HEPA Caudal constante Regulaci n fija PE N L PE N L Amarillo verde Azul Negro Q 3 230Vx1 50Hz Caja de conexione...

Страница 6: ...res bacteria viruses and fine particles PM10 PM2 5 and PM1 Self supporting galvanized steel frame prepared for recessed installation in false cei lings Easy access log panel for filter replacement Suc...

Страница 7: ...HEPA 7 DATASHEET Operation infographic Maintenance Air purified outlet Air inlet Indicator Filter change Service panel Service door for filters Threaded knob to adjust the position of the filters insi...

Страница 8: ...deadline An annual cleaning of the discharge area should be performed Cleaning of the unit casing should be done with a damp cloth and conventional detergent Do not use corrosive caustic or acid conta...

Страница 9: ...ese instructions Before carrying out any repairs you must Notify staff and indicate that work is in progress Disconnect the current and protect the thermal magnet so that no one can actuate it by acci...

Страница 10: ...filters under normal operating conditions is Prefilter G4 500 hours Compact filter F7 1000 hours Absolut filter H14 3500 hours It is recommended to check the condition of the filters every six months...

Страница 11: ...the current make sure that there is no voltage and the turbine does not rotate Open the service panel as indicated in the previous section The new fan is installed following the above procedure in re...

Страница 12: ...manual Purifier K7 770 HEPA 12 ACCESSORIES Supports and shock absorbers according to installation see references in attached document Standard cable clamp Silentblock in angle Silentblock rod damper R...

Страница 13: ...hes the equipment and if not check the power cables 3 1 If the equipment has voltage but the fan does not rotate check if there is 5 5V in continuous between the yellow and black cables 3 2 In case th...

Страница 14: ...e s directiva s Low Voltage Directive 2014 35 UE Directiva Baja Tensi n 2014 35 UE Electromagnetic Compatibility Directive 2014 30 UE Directiva Compatibilidad Electromagn tica 2014 30 UE Restriction C...

Страница 15: ...istics flow rate technical data of the fans It is essential to have this number to provide possible spa re parts or technical information on the purifier in question In case of detecting errors or amb...

Страница 16: ...Pla de la Bruguera E 08211 Castellar del Vall s Barcelona Spain 34 93 715 99 88 airtecnics airtecnics com www airtecnics com WELDOM10025 R0 17 09 21 We reserve the right to change design and specifica...