background image

1

ΜΟΝΑΔΑ ΑΝΑΚΤΗΣΗΣ ΕΝΕΡΓΕΙΑΣ

V. 4

Energy Recovery Ventilator

ENERGY BOX   TE

ENERGY BOX-TE 

150

 | ENERGY BOX-TE 

250

 | ENERGY BOX-TE 

350

 | ENERGY BOX-TE 

500

   ENERGY BOX-TE 

650

, ENERGY BOX-TE 

800

 | ENERGY BOX-TE 

1.000

   ENERGY BOX-TE 

1.300

 | ENERGY BOX-TE 

1.500

 | ENERGY BOX-TE 

2.000

ΤΥΠΟΙ 

 /  

MODELS

Содержание ENERGY BOX-TE 1.000

Страница 1: ...Ventilator ENERGY BOX TE ENERGY BOX TE 150 ENERGY BOX TE 250 ENERGY BOX TE 350 ENERGY BOX TE 500 ENERGY BOX TE 650 ENERGY BOX TE 800 ENERGY BOX TE 1 000 ENERGY BOX TE 1 300 ENERGY BOX TE 1 500 ENERGY...

Страница 2: ...ease keep this MANUAL in a safe place for future use CONTENTS Safety Unit specifications Dimensions Installation considerations Electrical installation Wiring diagrams Commissioning Intelligent contro...

Страница 3: ...r forbidden Must follow WARNING Unit must be installed strictly following the rules of this manual and mounted to a weight bearing surface During maintenance or repair the power supply must be disconn...

Страница 4: ...y flue gas discharge or areas where hazardous vapors are present Use only approved installation hardware and accessories Failure to comply can result in fire risk electric shock and equipment failure...

Страница 5: ...n should also be installed to avoid risk of electric shock or fire Do not use this device as the kitchen s primary air extraction system Grease accumulation can block the air flow at the heat exchange...

Страница 6: ...62 71 65 73 62 70 65 73 63 72 67 75 75 80 73 81 74 82 76 84 31 5 34 5 37 5 39 220 240V 1Ph 50 Hz 38 75 107 140 3 x 1 5 mm2 2 x 0 5 mm2 Yes 7 Day Time clock Yes BLDC With BLDC motor 10 10 Speed fan co...

Страница 7: ...2 3 x 1 5 mm2 2 x 0 5 mm2 Yes 7 Day Time clock Yes AC With AC Motor 10 10 Speed fan control 10 10 Speed fan control Yes automatic with adjustable range Yes automatic with adjustable range On Off Optio...

Страница 8: ...1Ph 50Hz 365 460 610 3 x 1 5 mm2 2 x 0 5 mm2 Yes 7 Day Time clock Yes BLDC With BLDC motor 10 10 Speed fan control 10 10 Speed fan control Yes automatic with adjustable range Yes automatic with adjus...

Страница 9: ...0 ENERGY BOX TE 500 804 814 100 675 862 19 480 111 270 144 904 894 107 754 960 19 500 111 270 194 A B C E F G I K M N ENERGY BOX TE 650 ENERGY BOX TE 800 884 1 186 85 1 115 940 19 428 170 388 242 1 13...

Страница 10: ...00 ENERGY BOX TE 2 500 Model 1 486 1 186 1 115 884 940 428 785 1 486 1 186 1 115 1 134 1 190 678 785 C L L1 W W1 W2 H H C W L1 W2 L W1 650 280 Installation diagram Suspending pole Air supply duct Air...

Страница 11: ...450 ENERGY BOX TE 1 000 ENERGY BOX TE 1 300 1 216 450 1 216 450 ENERGY BOX TE 1 500 884 835 During installation or storage you must prevent dust or other obstructions from entering the unit and the ac...

Страница 12: ...4 Reverse labeling shows the unit is upside down Installation Ducting 1 2 1 100 1 50 3 25 mm 1 The connections of the unit with the air ducts must be airtight to prevent air leakage and must comply wi...

Страница 13: ...re above 40 C and should not face an open fire 7 Take action to avoid dew and frost 8 To avoid the outdoor exhaust air cycling back indoor the distance between the two vents installed on the outside w...

Страница 14: ...ect the 2 wires L N to the terminals and connect the cable of the control panel to the board according to the wiring diagram and join the control panel to the cable WARNING WARNING ENERGY BOX TE 150 E...

Страница 15: ...utput Fire alarm signal input By pass switch External switch Diferrential pressure switch temp RA temp OA temp FR EA temp SA sensor CO 2 Control panel ports RS485 ports Humidity sensor Dial switch Con...

Страница 16: ...al pressure switch temp RA temp OA temp FR EA temp SA sensor CO 2 Control panel ports RS485 ports Humidity sensor Dial switch Control panel Electrical heater signal Joint of control panel and cable le...

Страница 17: ...MODE for 6 seconds to enter parameter settings and at this time the parameter number is shown in the middle of the screen press button SET to switch to parameter No 21 then press MODE to enter the par...

Страница 18: ...ss MODE to modify the value according to the current oA temperature by pressing up down button and press SET to save the data At the same time check the bypass is opened or not Please remember to modi...

Страница 19: ...poor indoor air quality The air supply must not be in a close proximity to a burner otherwise it may cause insufficient burning Don t install the fresh air duct in hot and humid conditions as it may c...

Страница 20: ...ler is surface mounted and comes with a LCD display screen The standard connection cable is 5 meters but you can prepare extra cable if necessary EN LCD LCD display screen By pass By pass on Power on...

Страница 21: ...ir Fan speed Air temperature ON OFF Display screen ON OFF Power ON OFF Power on indicator Time Temperature Temperature Time Function selection Time settings Day selection Weekly program timer ON Save...

Страница 22: ...tion without saving the data If 8 seconds pass without user input display will disappear and all settings are invalid 5 Day setting press the DAY button when the day flashes users can choose Monday to...

Страница 23: ...is already stopped it remains inactive The timer on and off can be used independently or simultaneously 10 Controller settings are kept after restarting from power off 11 Temperature setting after con...

Страница 24: ...frosting entering temperature Defrosting duration time CO2 CO2 sensor function value ModBus Energy Box ID address Energy Box Energy Box models match selection Fan speed display selection Multiple func...

Страница 25: ...defrosting time is longer than 10 minutes adjustable 15 Filter Alarm 1 With timer To set the filter alarm go to parameter 25 The filter alarm symbol flashes to remind the user to clean the filters In...

Страница 26: ...or error description EN Error description E1 E2 E3 E4 Code E5 E6 E7 E8 Fresh air temperature sensor error EEPROM EEPROM error Return air temperature sensor error Exhaust air temperature sensor error d...

Страница 27: ...fan speed Exhaust fan speed Room temperature Outdoor temperature Exhaust air temperature Observed value Main control Main control Main control Main control Main control Main control Main control Main...

Страница 28: ...ain control Defrosting method B0 1 Fire alarm ON B1 1 Bypass ON B2 1 Bypass OFF B3 1 Defrosting B2 OA temperature error B5 EEPROM error B4 RA temperature error B3 Fr temperature error auto defrosting...

Страница 29: ...hes off for 10 minutes and restarts b If the OA heater switches on and the exhaust air temperature still 1 C then the ventilator stops for 50 minutes c If the exhaust air temperature 1 C and the outdo...

Страница 30: ...with national regulations Failure to observe could cause unit failure electric shock or fire Standard filtration is supplied with this unit and must be used Dust and dirt can accumulate in the heat ex...

Страница 31: ...rial operation In case of failure consult with the following troubleshooting guide If no solution can be found please contact our technical department Failure diagnose The airflow in both indoor and o...

Страница 32: ...Office ATHENS Michail Karaoli Str 19 14343 Nea Chalkidona Athens 211 705 55 00 sales airtechnic gr AIR HANDLING UNITS HEAT EXCHANGERS FIRE DAMPERS AIR OUTLETS FANS FAN SECTIONS CENTRAL VACUUM SYSTEMS...

Отзывы: