28
Picture 15 (View in system manager)
Slot Configuration
: After closing the scanning window, the following screen
should appear:
Click on the
re46-profinet
and then on the
API
-Node to open the details of the
I/O-Configuration.
The
API
consists of up to 7 entries:
DAP (Data Access Point)
- The fieldbus access of the device
Slot#1
- Solenoid 01-08 (valve outputs)
Slot#2
- Solenoid 09-16 (valve outputs)
Slot#3
- Solenoid 17-24 (valve outputs)
Slot#4
- Solenoid 25-32 (valve outputs)
Slot#5
- Solenoid 33-40 (valve outputs)
Slot#6
- Solenoid 41-48 (valve outputs)
Depending on the size of your RE-46 PROFINET the number of outputs will dif-
fer:
HINTS:
For valve terminals with 1-8 valve stations
2 modules (Slots) with 1 submodule
for valve terminals with 9-16 valve stations
4 modules (Slots) with 1 submodule
for valve terminals with 17-24 valve stations
6 modules (Slots) with 1 submodule
each
Important: Only an even number of modules (Slots) is allowed, i. e. 2, 4 or 6.
If this is disobeyed, the RE-46 will not work on your Controller!
Inputs
Outputs
Содержание RE-46
Страница 6: ...6...