En-2

]1

2.3. Accessories

 

WARNING

For installation purposes, be sure to use the parts supplied by the manufacturer or other 
prescribed parts. 
The use of non-prescribed parts can cause serious accidents such 
as the unit falling, water leakage, electric shock, or 

fi

 re.

•  The following installation parts are furnished. Use them as required.
•  Keep the Installation Manual in a safe place and do not discard any other accessories 

until the installation work has been completed. 

Name and Shape

Q’ty

Application

Operating Manual

1

Installation Manual

1

(This book)

Wall hook bracket

1

For indoor unit installation

Cloth tape

        

1

For indoor unit installation

Tapping screw (Big)
(M4 × 25mm)
 

    

8

For wall hook bracket installation

Air cleaning 

fi

 lter

       

2

For installation, refer to the “CLEAN-
ING AND CARE” in the operating 
manual.

Air cleaning 

fi

 lter frame

       

2

Drain hose Insulation

  

1

For installing drain hose

Connecting cable

       

1

For wired remote controller cable 
connected

Cable tie

       

1

For transmission and remote con-
troller cable binding

]1

2.4. Optional parts

Description

Part No.

Application

External output wire B

9379529013

For output port

External input wire D

9368779016

For control input port

(Apply voltage terminal)

External input wire F

9368779023

For control input port

(Dry contact terminal)

External input wire B

9368778002

For forced thermostat off port

(Apply voltage terminal)

External input wire E

9368778019

For forced thermostat off port

(Dry contact terminal)

3. INSTALLATION WORK

Correct initial installation location is important because it is dif

fi

 cult to move unit after it is 

installed. 

]1

3.1. Selecting an installation location

Decide the mounting position together with the customer as follows.

 

WARNING

Select installation locations that can properly support the weight of the indoor unit. 
Install the units securely so that they do not topple or fall.

 

CAUTION

Do not install the indoor unit in the following areas:
•  Area with high salt content, such as at the seaside. It will deteriorate metal parts, 

causing the parts to fail or the unit to leak water.

•  Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam, 

such as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit 
to leak water. 

•  Area that generates substances that adversely affect the equipment, such as 

sulfuric gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed 
joints to corrode, which can cause refrigerant leakage. 

•  Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable dust, or volatile in

fl

 ammables such as paint thinner or gasoline. If gas 

leaks and settles around the unit, it can cause a 

fi

 re.

•  Area where animals may urinate on the unit or ammonia may be generated.

Do not use the unit for special purposes, such as storing food, raising animals, 
growing plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.

Do not install where there is the danger of combustible gas leakage.

Do not install the unit near a source of heat, steam, or 

fl

 ammable gas.

Install the unit where drainage does not cause any trouble.

Install the indoor unit, power supply cable, transmission cable, and remote controller 
cable at least 1 m away from a television or radio receivers. The purpose of this is to 
prevent TV reception interference or radio noise. (Even if they are installed more than 
1 m apart, you could still receive noise under some signal conditions.)

If children under 10 years old may approach the unit, take preventive measures so 
that they cannot reach the unit.

Take precautions to prevent the unit from falling.

(1)  Install the indoor unit on a place having a suf

fi

 cient strength so that it withstands 

against the weight of the indoor unit.

(2)  The inlet and outlet ports should not be obstructed; the air should be able to blow all 

over the room.

(3) Leave the space required to service the air conditioner.
(4) Install the unit where connection to the outdoor unit (or RB unit) is easy. 
(5) Install the unit where the connection pipe can be easily installed. 
(6) Install the unit where the drain pipe can be easily installed.
(7) Install the unit where noise and vibrations are not ampli

fi

 ed. 

(8)  Take servicing, etc., into consideration and leave the spaces. Also install the unit 

where the 

fi

 lter can be removed.

(9) Do not install the unit where it will be exposed to direct sunlight.

]1

3.2. Installation dimension

For the drain hose exten-
sion, use a drain hose 
with a 16 mm inside 
diameter.

1800 mm or 
over

1500 mm 
or over

Right side 
200 mm or 
over

60 mm or over

Left 
side 
50 mm 
or over

Wall hook bracket

9373370147-02_IM.indb   2

9373370147-02_IM.indb   2

1/21/2013   4:10:04 PM

1/21/2013   4:10:04 PM

Содержание ASHA18GACH

Страница 1: ...APPAREIL INT RIEUR Type montage mural UNIDAD INTERIOR Tipo montado en pared Pour le personnel agr uniquement nicamente para personal de servicio autorizado Italiano MANUALE DI INSTALLAZIONE UNIT INTE...

Страница 2: ...rvice person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 1 2 1 Precautions for using R410A refrigerant WARNING Do no...

Страница 3: ...ates substances that adversely affect the equipment such as sulfuric gas chlorine gas acid or alkali It will cause the copper pipes and brazed joints to corrode which can cause refrigerant leakage Are...

Страница 4: ...y strong so that the wall can support the weight Fig A UNIT mm UNIT centre UNIT size UNIT size hole hole hole for tapping screw 80 hole 80 hole Piping inlet Piping inlet hole hole hole hole hole hole...

Страница 5: ...flare R410A pipes the dimension A should be approximately 0 5 mm more than indicated in the table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure...

Страница 6: ...breaking of the pipe avoid sharp bends If the pipe is bent repeatedly at the same place it will break For 1 Rear piping 2 Right piping and 3 Bottom piping Install the indoor unit piping in the direct...

Страница 7: ...ly making sure that there are no external forces of the cables applied to the terminal connections Improperly connected or secured cables can cause serious accidents such as overheating the terminals...

Страница 8: ...1 Use ring terminals with insulating sleeves as shown in the figure below to connect to the terminal block 2 Securely clamp the ring terminals to the cables using an appropriate tool so that the cabl...

Страница 9: ...ld be separate from the power cable line 6 3 3 Remote controller cable Remote controller cable modification 1 Use a tool to cut off the terminal on the end of the remote controller cable and then remo...

Страница 10: ...d at the input device you want to connect use the Apply voltage terminal CNA01 CNA03 Input device 1 Input device 2 Input device 3 Load resistance Load resistance Load resistance 1 DC power supply 12 t...

Страница 11: ...operation 3 Connection methods Wire modification Remove insulation from wire attached to wire kit connector Remove insulation from field supplied cable Use crimp type insulated butt connector to join...

Страница 12: ...frigerant system set the address at IU AD SW as shown in the Table A 2 Refrigerant circuit address Rotary switch REF AD 1 Factory setting 0 Rotary switch REF AD 10 Factory setting 0 In the case of mul...

Страница 13: ...oling temperature setting range OFF Factory setting Standard 18 to 30 C ON Extension 18 to 32 C NOTE Please do not make a standard setup and an extension setup intermingled in remote controller group...

Страница 14: ...lamp Green FILTER indicator lamp Red TIMER indicator lamp Orange 7 4 2 Checking the function settings Press and hold the MANUAL AUTO button on the indoor unit for 3 seconds to check the function sett...

Страница 15: ...6 Center piping and 7 Left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with vinyl tape so that there is no gap 1 Rear 2 Right and...

Страница 16: ...ge Are the wires and pipes all connected completely No operation heat or burn damage Is the indoor unit earthed grounded Short circuit Is the connection cable the specified thickness No operation heat...

Страница 17: ...n manual of the remote controller 2 digit numbers are corresponding to the error code in the preceding table Touch the Next Page or previous page to switch to other indoor unit information UTY RNKY UT...