7 Power System Connection
Hazardous voltage!
Before working, ensure that the power is removed from the
power connection cables. When the system is powered on,
do not touch the
power terminals
.
7.1 Required Tools
The tools required for the connection of the PSU are:
knife
small flat blade screw driver (electrical insulated shaft recommended)
medium Philips head screwdriver
pliers
small side cutters
tweezers (or fine blade long nose pliers)
Figure 32 - required tools
7.2 Cable Connections
7.2.1 DC Power Cable Installation
When the DC power cable is to be passed through glands and/or down the center of a lamp post
or other structure, the DC power cable can be cut leaving sufficient length for ease of termination
.
With the power supply placed at the selected installation location, trim the cable to the length for
proper installation while allowing sufficient length to strip and prepare the cable ends.
Note:
Standard cable supplied is 30m in length, other length options are
available.
Note:
Airspan supplies two (2) types of cable, either black wire and white wire
cable or black wire and blue wire cable. The cables
’ specs are identical only the
colors are different.