Airrex AH-200i Скачать руководство пользователя страница 3

31

SAFETY INSTRUCTIONS

The purpose of these safety instructions is to ensure the safe use of the Airrex heaters. Adherence to these 

instructions prevent the risk of injury or death and damage to the heating device as well as other items or premises.
Please read the safety instructions with care.

The instructions feature two concepts: “Warning” and “Note”.

T

his marking

 indicates a risk of injury and/or death.

KEEP THESE INSTRUCTIONS ACCESSIBLE NEAR THE DEVICE TO ALL USERS.

This marking indicates the risk of minor injury or structural damage.

Only use 220/230 V mains electricity. 

Incorrect voltage may cause a fire or electrical 

shock.

Always ensure the condition of the power cord and 

avoid bending it or placing anything on the cord. 

A damaged power cord or plug may 

cause a short circuit, electric shock, or even fire.

Do not handle the power cord with wet hands. 

This may cause a short circuit, fire, or risk of 

death.

Never use any containers carrying flammable 

liquids or  aerosols near the heater or leave them  

in its immediate vicinity due to the fire and/or 

explosion risk they present.

Ensure that the fuse adheres to the 

recommendation (250 V / 3.15 A). The wrong fuse 

may cause malfunctions, overheating or a fire.

Do not deactivate the heater by cutting 

the power supply or disconnecting the power plug. 

Cutting power during heating may lead to 

malfunctions or an electric shock. Always use the 

power button on the device or the ON/OFF button on 

the remote control.

Damaged power cords must be replaced 

immediately at a maintenance shop 

authorised by the manufacturer or importer 

or some other maintenance shop authorised for 

electrical repairs.

If the plug gets dirty, clean it carefully before 

connecting it to the socket. A dirty plug may 

cause a short circuit, smoke and/or fire.

Do not extend the power cord by connecting 

additional lengths of cord to it or its 

connector plugs. Poorly-made connections 

may cause a short circuit, electric shock or 

fire.

Before cleaning and maintaining the device, 

disconnect the power plug from the socket and 

allow the device to cool down sufficiently. 

Neglecting these instructions may lead to burns 

or an electric shock.

The power cord of the device may only

be connected to a grounded socket.

Do not cover the heater with any obstructions

such as clothing, fabric or plastic bags. 

This may cause a fire.

SYMBOLS USED IN THE MANUAL:

Prohibited measure

Mandatory measure

Put the plug into the socket-outlet tightly, 

otherwise it may cause an electric shock.

Do not place any inflammable material near the 

heater, including curtain, carpet. paper, match, 

clothes, etc. Otherwise it is exposed to danger of fire.

SUOMI   

ENGLISH

   SVENSKA   NORSK   D

ANSK 

Содержание AH-200i

Страница 1: ...hese heaters have been adjusted to function in Northern European conditions If you take the heater to other areas check the mains voltage in your country of destination This user manual also includes...

Страница 2: ...O APPLICATION 41 CONNECTING HEATER TO APPLICATION 42 TIPS FOR USING MOBILE APPLICATION 43 USING MOBILE APPLICATION 44 NOTICE WHEN USING MOBILE APPLICATION 45 INTERNAL LTE ROUTER OPTIONAL 45 MAINTENANC...

Страница 3: ...heater by cutting the power supply or disconnecting the power plug Cutting power during heating may lead to malfunctions or an electric shock Always use the power button on the device or the ON OFF b...

Страница 4: ...n falling off the heater Only use the heater in well ventilated open spaces where the air is replaced 1 2 times an hour Using the heater in poorly ventilated spaces may generate carbon monoxide which...

Страница 5: ...ry location indoors Do not store in hot or particularly humid spaces Possible corrosion caused by humidity may cause malfunctions ENSURE THE SAFETY OF THE HEATER S LOCATION The vicinity of the heater...

Страница 6: ...eat reflector rear Heat reflector side Heat reflector bottom Power cord 220 230 V AC Control panel Overheating sensor Fuel pump Fuel cap Fuel tank Intake air opening Ignition unit Tilt sensor Fuel gau...

Страница 7: ...t with the corresponding marking in the case 3 CLOSING THE BATTERY CASE Push the battery case into place until you hear the lock click Aim the end of the remote control towards the heater Strong sunli...

Страница 8: ...36 BURNER STRUCTURE BURNER MOTOR AIR INTAKE FLAME DETECTOR FUEL HOSE BLEED SCREW FUEL PUMP FUEL FILTER IGNITION UNIT SOLENOID WINDOW FOR VIEWING THE COMBUSTION CHAMBER HEATER STRUCTURE...

Страница 9: ...d temperature and set the length of the heating cycle 8 OPERATION LAMP This light is on when the burner is operating 9 SHUTDOWN TIMER This button activates or deactivates the shutdown timer function 1...

Страница 10: ...T O U SE OPERATION STOP In order to operate set the temperature higher than room temperature After power On the default mode is temperature control mode During the operation if you push power button...

Страница 11: ...h running and stop repeatedly to meet this temperature If power ON and Heater starts operation the temperature control mode will be operated as default TEMPERATURE CONTROL The room temp is less than 9...

Страница 12: ...ically erased 4 At the operation mode the operation symbol and repetition time both are displayed and when you make off by pushing power button STOP symbol Interval pause time STOP symbol and repetiti...

Страница 13: ...ngdom 3 Install the application REGISTER AS A USER TO APPLICATION 3 Check your email inbox and verify your email by clicking the button link in your email 2 Enter your e mail and desired password twic...

Страница 14: ...Turn the heater power off and press the up button for 5 seconds Then the bluetooth icon flashes Press NEXT button in the application 8 Choose your Wi Fi network by pressing the Wi Fi selection After c...

Страница 15: ...you make off by pushing power button STOP symbol Interval pause time STOP symbol and repetition time both displayed 5 The repitition time can be set from 10min to 55min The operation is as much as se...

Страница 16: ...ou can logout if necessary 2 If you want to change your password click this button You will receive an email with instructions to change the password 3 Select to turn push notifications on off 4 Here...

Страница 17: ...erred to the product modem and might not be connected You might not be able to connect depending on your network settings or connection status If you are not connected or have problems setting up your...

Страница 18: ...he fuel system BLEEDING THE FUEL SYSTEM 1 Loosen the bleeder wing nut at the bottom of the fuel pump by 2 3 rotations 2 Start the heater 3 When you hear the fuel pump start wait for 2 3 seconds and cl...

Страница 19: ...all the safety mesh after cleaning To disconnect the front safety grill lift it slightly and pull it off Install the grill by performing these steps in reverse order YEARLY MAINTENANCE It is recommend...

Страница 20: ...EANING MAINTENANCE LOGBOOK Date Maintenance done by Maintenance done Date Maintenance done by Maintenance done Date Maintenance done by Maintenance done Date Maintenance done by Maintenance done Heate...

Страница 21: ...r display of the oil shortage and amount of oil reached to the below limit level oil shortage lamp is ON and post purge works and all other operations stop 6 PREHEATING TEMPERATURE SENSOR CHECKING It...

Страница 22: ...r message Flame sensor issue The flame sensor detects light before the burner is activated Ensure that the flame sensor is positioned properly The sensor may also be damaged ER 2 error message Tempera...

Страница 23: ...try again The wifi light blinks once on the heater display and the mobile app keeps going offline 1 Check your wireless router for internet connection It is also good to turn the power off and on 2 Pr...

Страница 24: ...kcal h 22kW h 18 920 kcal h Fuel Biodiesel diesel Fuel comsumption 0 95 1 14 L h 1 14 1 33 L h 1 71 1 9 L h Burner type Electric pump pressurized spray type Power supply 220 230Vac 50Hz Single phase...

Страница 25: ...d It is important to ensure that air circulates in the space being heated Ideally air should be fed in through an inlet vent at the bottom and the CO2 containing air should be discharged through an ou...

Страница 26: ...nt implementation thereof The warranty limitations have been described in more detail in Section 6 The warranty only covers Rex Nordic Oy products imported by Rex Nordic Oy and sold by an official dea...

Страница 27: ...nty certificate or another reliable clarification on where and when the device was purchased When estimating a reasonable repair time the degree of defect shall be taken into account in consideration...

Страница 28: ...ic com WHY OUR SERVICE 1 We are the official service shop for Airrex products 2 We only use original spare parts 3 All spare parts for devices are available in our warehouse 4 A well trained professio...

Отзывы: