background image

15

TROUBLE SHOOTING

 

PROBLEM 

 

 

CAUSE   

 

        SOLUTION

 

    No Power supply ? 

 

 

 

   Check the power supply is proper.

  

 

 

 

 

 

 

   (ex. 220/230V a.c. 50Hz)

  

   Check power plug is  

 

 

 

   Power plug into the outlet

 

   disconnected

 

   Is the Fuse short ?  

 

 

                 Replace fuse with new one

 

 

 

 

 

 

 

   (250V a.c. 3.15A)

 

   ‘Lack of Fuel” light ON ?  

 Lack of Fuel 

   

   Fill it up with kerosene or Diesel

                                                                                                   

♣ Do not mix or use together these two different fuel.          

 

                 Is set temp. lower than  

 

 

 

   Set the temp as higher than current

 

   current temp.? 

 

 

 

 

   temp.

 

   Misfire lamp ON?   

 Air in the electric pump.              Remove the air in the electric pump.

 

 

 

 

 

 

 

   (Refer to page 19)

 

   Overheating Lamp ON?   

 Under operation of                    Ventilate with fresh air in the room,

 

 

 

 

 overheating prevention  

   and turn OFF the heater for a while

 

 

 

 

 

 

 

   (Refer to page 16)    

 

  

 

   Inclination display                 Ground surface is inclined           Replace the heater in plain ground

 

   lamp ON? 

 

or not plain 

 

    (Refer to page 16)

 

   Can you see”Er2”                Error on Temperature   

   Select Timer control operation from

 

   on the display? 

 

sensor 

 

 

   temperature control mode.

 

 

 

 

 

 

 

   (Refer to page 16)

                  
                  Is fuel filter stuffy?                Filter is contaminated 

   Clean the filter with compressed air,

  

 

 

 

 

 

 

   or replace with new one. 

 

 

 

 

 

 

 

   (Refer to page 18)

                 
                  Is air suction valve 

 

 

 

   Call after sales service agent.

                  adjusted excessively  
                  or too small ?

 

    Voltage is low?   

 In case of low voltage 

   Burner will not work properly, so use

 

 

 

 

 

 

 

   a booster to elevate voltage. (A/S)

Is Power ON?

Is Fuel enough?

Is Flame sensor clean?

Please check below points before you think trouble 
has been occurred.

Wide IR Window

현재온도

시간

온도

시간

설정온도/시간

연료절약

Содержание AH-1330

Страница 1: ...that the user read Notice for Safety carefully before using and should be aware of this notice whenever using this heater This heater is designed for your country only If you use it in another country...

Страница 2: ...d to fire or burn It is dangerous to use this heater for a long time in the closed room or in case there are children or the old and the weak It is recommended that the user open the windows to let fr...

Страница 3: ...CONTROLLER REMOTE CONTROLLER HOW TO USE OPERATION STOP TEMPERATURE CONTROL SELF DIAGNOSIS FOR THE SAFETY DEVICE CLEANING MAINTENANCE DAILY CHECK POINTS ADJUSTMENT TROUBLE SHOOTING SPECIFICATION ELECTR...

Страница 4: ...g from the outlet wait until the heated furnace is cooled down sufficiently Otherwise it may cause an electric shock or a burn Do not place or use any inflammable near the heater including fuel gas th...

Страница 5: ...r you fix the installation lock the caster for avoiding unexpected movement Do not use this heater near fabri curtain carpet or plastic or vinyl curtain which may cover th heater in case of falling do...

Страница 6: ...rformance Wide IR Window overheating sensor Automatic Recovery Electronic fuel pump Fuel inlet Fuel tank Air suction hole Igniter Tilt sensor Fuel guage burner Flame sensor CdS Fuel filter Control pan...

Страница 7: ...s term To release press this switch for 1 second then off timer mode will be released 10 OFF TIMER LED To show whether timer off mode is operating or not 11 Fuel Guage display It displays fuel remain...

Страница 8: ...en using the remote control for the first time remove the vinyl battery contact cover Point remote control at machine receiver Remote control will not function where strong lights such as 3 florescent...

Страница 9: ...d inflammability The model equipped solenoid valve by pass device makes the remaining oil returned to the oil tank For 10sec from the time of burner off the solenoid valve is operation which makes rem...

Страница 10: ...utton for 5sec simultaneously the unit is converted from to or from to The defaulte unit is 1 Push On Off button 4 During operaton the current temp and setting temp both are displayed and if you push...

Страница 11: ...en after display of the oil shortage and amount of oil is reached to the below limitation level oil amount lamp is OFF and post fuggy is worked and all other operation is stop 5 Safety operation Displ...

Страница 12: ...s in the back side of heater and burner area The burning pipe is coated by ceramic material so careful clean not to damange to the coating Do not disassemble the burning parts Please wipe out the fron...

Страница 13: ...xed correctly Mark A should be inserted fully Change of components In case you need to change components please contact us In case repair or exchange of components please contact the service center op...

Страница 14: ...d not distribute oil If oil is all consumed without remaining in the tank air can be flow into inside electric pump The method to flow out air Operate the heater When the electric pump operated turn o...

Страница 15: ...the room overheating prevention and turn OFF the heater for a while Refer to page 16 Inclination display Ground surface is inclined Replace the heater in plain ground lamp ON or not plain Refer to pag...

Страница 16: ...sive air in the Remove the air in the electric pump pump and nozzle Check if the fuel is It may cause less Drain the existing fuel and fill with Diesel or kerosene performance trouble Diesel or kerose...

Страница 17: ...surized spray type Power supply a c 220 230V 50Hz Single Phase Electric power consumption 80W Fuel tank size 45 Product size W x D x H WEIGHT 41 kg Safety device Overheating sensor Auto misfire detect...

Страница 18: ...e will offer you free repair service under our warranty clause 1 Warranty period is 12 months after purchasing date If the problem is occurred by the mistake or misuse of the customer we charge a repa...

Отзывы: