15
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No Power supply ?
Check the power supply is proper.
(ex. 220/230V a.c. 50Hz)
Check power plug is
Power plug into the outlet
disconnected
Is the Fuse short ?
Replace fuse with new one
(250V a.c. 3.15A)
‘Lack of Fuel” light ON ?
Lack of Fuel
Fill it up with kerosene or Diesel
♣ Do not mix or use together these two different fuel.
Is set temp. lower than
Set the temp as higher than current
current temp.?
temp.
Misfire lamp ON?
Air in the electric pump. Remove the air in the electric pump.
(Refer to page 19)
Overheating Lamp ON?
Under operation of Ventilate with fresh air in the room,
overheating prevention
and turn OFF the heater for a while
(Refer to page 16)
Inclination display Ground surface is inclined Replace the heater in plain ground
lamp ON?
or not plain
(Refer to page 16)
Can you see”Er2” Error on Temperature
Select Timer control operation from
on the display?
sensor
temperature control mode.
(Refer to page 16)
Is fuel filter stuffy? Filter is contaminated
Clean the filter with compressed air,
or replace with new one.
(Refer to page 18)
Is air suction valve
Call after sales service agent.
adjusted excessively
or too small ?
Voltage is low?
In case of low voltage
Burner will not work properly, so use
a booster to elevate voltage. (A/S)
Is Power ON?
Is Fuel enough?
Is Flame sensor clean?
Please check below points before you think trouble
has been occurred.
Wide IR Window
현재온도
시간
분
온도
시간
설정온도/시간
연료절약