background image

 

Page 

4

 of 

5

 

 

ZIP 

(FOR ACCESSING THE FLEXI PIPE) 

 

AIR RELEASE FLAP 

Fig

4

 

 
 

-  There is a second flexi pipe inside the unit. It is located in the chamber underneath the mouth. 

Its function is to direct the airflow from the bed into the top parts of the unit. Without this pipe, 
the head of the crocodile wouldn’t inflate. Before inflating the unit, you must make sure this 
flexi pipe is connected on both sides, and is fully functional. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

You can verify them through the zip shown on the picture below. 

 

 
 
 
 
 
 
 

 

 
 
 

-  Switch on all fans to start inflation. Check around the Slide to make sure that it does not come 

into contact with any obstructions. 

-  For the jaw to be able to drop, the fan must stop, and the air has to exit through the 

“Air Release 

Flaps

” seen on fig. 4. You can automate this movement of the jaw by connecting the supplied 

electrical timer between the main electric socket and the electrical socket of the 2HP fan, which 
will turn the fan ON and OFF in the selected time intervals. 

 
 
 

 

 

 

 

 

2HP FAN SOCKET 

ELECTRICAL SUPPLY SOCKET 

BED

 

 

TOP PART

 

 

AIRFLOW

 

 

Содержание Active Crocodile Slide

Страница 1: ...ny overhead underground cables It s important that this is carried out to avoid ground anchors penetrating underground services and the Active Crocodile Slide coming into contact with overhead cables when inflated 2 You should provide an adequate power supply to the fan this should adhere to your local power regulations 3 Check wind speed The industry recommends a maximum wind speed of Force 5 on ...

Страница 2: ...nsion lead Crash Mats This inflatable can be set up and packed away by 2 persons who have had proper manual handling training and use the correct equipment to move the inflatable Intended use of the product Please be aware that this is not a bouncy castle and should not be used for bouncing on The inflatable in its bag Electrical Timer Anchor Pegs Intended user height and number User Height UP to ...

Страница 3: ... a flexible plastic pipe inside fig 1 that directs the airflow directly from the fan into the chamber beneath the mouth It is imperative to tie the strap at the proximity of the bed outside fig 2 and in the chamber beneath the mouth inside fig 3 because these cam buckle webbing straps secures the flexi pipe and prevent it from moving 16 GROUND ANCHOR POINTS IN TOTAL FLEXIBLE PIPE INSIDE THE UNIT 2...

Страница 4: ...functional You can verify them through the zip shown on the picture below Switch on all fans to start inflation Check around the Slide to make sure that it does not come into contact with any obstructions For the jaw to be able to drop the fan must stop and the air has to exit through the Air Release Flaps seen on fig 4 You can automate this movement of the jaw by connecting the supplied electrica...

Страница 5: ... on for 15 seconds and off for 25 seconds hence asymmetrical IMPORTANT PLEASE MAKE SURE THAT THE TIMER HAS BEEN DISCONNECTED FROM THE POWER SUPPLY BEFORE REMOVING THE LID In order to adjust the timer first you ll need to remove the plastic lid Inside the box you will find 4 dials With the help of these you ll be able to adjust the desired ON and OFF time intervals see images below Once you have se...

Отзывы: