Airphx CID 75k Скачать руководство пользователя страница 27

 

  27 | Page 

Disclaimer 

The express warranties provided herein are the exclusive warranties given by AIRPHX and 

supercede any prior, contrary or additional representation/warranties, written or oral. ANY 

IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND/OR FITNESS FOR 

A PARTICULAR PURPOSE THAT APPLY TO ANY PARTS DESCRIBED ABOVE ARE LIMITED IN 

DURATION TO THE PERIODS OF EXPRESS WARRANTIES GIVEN ABOVE FOR THOSE SAME PARTS. 

AIRPHX HEREBY DISCLAIMS AND EXCLUDES THOSE WARRANTIES THEREAFTER. SOME STATES DO 

NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE 

LIMITATION MAY NOT APPLY TO YOU. AIRPHX ALSO HEREBY DISCLAIMS AND EXCLUDES ALL 

OTHER OBLIGATIONS OR LIABILITIES, EXPRESS OR IMPLIED ARISING BY LAW OR OTHERWISE 

WITH REGARD TO ANY NONCONFORMANCE OR DEFECT IN ANY PRODUCT, INCLUDING BUT NOT 

LIMITED TO: (A) ANY OBLIGATION, LIABILITY, RIGHT, CLAIM, OR REMEDY IN TORT, WHETHER OR 

NOT ARISING FROM THE NEGLIGENCE OF AIRPHX OR ITS SUPPLIERS (WHETHER ACTIVE, PASSIVE 

OR IMPUTED) AND (B) ANY OBLIGATION, LIABILITY, RIGHT, CLAIM OR REMEDY FOR LOSS OF OR 
DAMAGE TO ANY EQUIPMENT. THIS DISCLAIMER AND RELEASE SHALL APPLY EVEN IF THE 

EXPRESS WARRANTY SET FORTH ABOVE FAILS IN ITS ESSENTIAL PURPOSE. 

Exclusive Remedies 
For any product described above that fails to conform to its warranty, an AIRPHX representative 

will exclusively provide repairs provided the equipment has not been subject to casualty, misuse, 

abuse, service or modification performed and not authorized by an AIRPHX representative. 

Service must be obtained by calling AIRPHX at 1 (855) 4  AIRPHX / 1 (855) 424-7749. THESE 

SHALL BE THE SOLE AND EXCLUSIVE REMEDIES OF THE BUYER FOR ANY BREACH OF WARRANTY. 

AIRPHX AND/OR ITS SUPPLIERS, DEALERS AND DISTRIBUTORS SHALL HAVE NO OBLIGATION OR 

LIABILITY, WHETHER ARISING IN CONTRACT (INCLUDING WARRANTY), TORT (INCLUDING ACTIVE, 

PASSIVE, OR IMPUTED NEGLIGENCE AND STRICT LIABILITY), OR OTHERWISE, FOR DAMAGE TO 

THE EQUIPMENT, PROPERTY DAMAGE, LOSS OF USE, REVENUE OR PROFIT, COST OF CAPITAL, 

COST OF SUBSTITUTE EQUIPMENT, ADDITIONAL COSTS INCURRED BY BUYER (BY WAY OF 

CORRECTION OR OTHERWISE) OR ANY OTHER INCIDENTAL, SPECIAL, INDIRECT, OR 

CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NON-DELIVERY OR FROM THE USE, 
MISUSE OR INABILITY TO USE THE PRODUCT. THIS EXCLUSION APPLIES EVEN IF THE ABOVE 

WARRANTY FAILS OF ITS ESSENTIAL PURPOSE AND REGARDLESS OF WHETHER SUCH DAMAGES 

ARE SOUGHT FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, OR STRICT 

LIABILITY IN TORT OR UNDER ANY OTHER LEGAL THEORY. 

 
 

Содержание CID 75k

Страница 1: ...1 Page AIRPHX CID 75k User Installation Guide Rev 1 7 February 22 2021...

Страница 2: ...C power cord o CID 75k Quick Reference Guide o AIRPHX 7 Day Timer User Guide o Annual supply of filters o Welcome card o Complete Indoor Disinfection decal Choose a central mounting location that has...

Страница 3: ...s that can cause the CID 75k to go into standby 8 6 Operations Controls 9 On Off Switch 9 Active Indicator 9 7 Day Timer Switch 9 Filter Indicator Switch 9 Filter Note 9 7 Operations Controls cont 10...

Страница 4: ...et Procedure 16 Filter Location 16 14 Filter Replacement and Reset Procedure cont 17 15 Filter Replacement and Reset Procedure cont 18 16 Plasma Chamber Replacement and Reset Procedure 19 17 Plasma Ch...

Страница 5: ...location for the CID 75k within the treatment area o Avoid locations with high humidity like swimming pools whirlpools and showers High moisture levels can damage the CID 75k s plasma chamber o Mount...

Страница 6: ...epairs to the CID 75k must be performed by qualified service personnel Please contact your AIRPHX representative with any service request Do not open the CID 75k for any reason Doing so may put you at...

Страница 7: ...F position and its LED is not illuminated 7 Day Timer Mode In this mode of operation the CID 75k will be controlled by the schedule that has been programmed into the 7 Day Timer The 7 Day Timer mode i...

Страница 8: ...lacement and Reset Procedure for more details 2 The unit has been in operation for a year and it is time to replace the plasma chamber In this situation the Service LED will illuminate red indicating...

Страница 9: ...n of the CID 75k is controlled by schedules programmed into the 7 Day Timer During an off schedule program the unit will go into standby awaiting an on schedule program to resume and the Active LED wi...

Страница 10: ...on the unit s LCD display location on the front of the unit Some faults can be reset after they have been cleared by pressing the Fault Indicator button Example of clearing a fault Removing the plasm...

Страница 11: ...st first remove the wall mount section from the back of the unit This is done be separating the two halves of the mount To separate the two halves you must first remove the two Phillips screws located...

Страница 12: ...lips Screws Recommended tools Level Pencil Long Phillips Screwdriver Punch or Scratch Awl Drilling Threaded Drywall Anchor Phillips Screw Wall Mount Section Phillips Locking Screws Top of Mount CID 75...

Страница 13: ...rewdriver It may be easier to start the anchor if you make a small hole first using a Scratch Awl 6 Screw the anchors in all the way until the outer rim of the anchor is flush with the drywall 7 Using...

Страница 14: ...14 Page 11 Installation Procedure Fig 1 Fig 1 Wall Mount Locking Screws...

Страница 15: ...15 Page 12 Installation Procedure Fig 2 Wall Fig 2 Top Wall Section of the Vesa Mount Threaded Anchors CID 75k Section of the Vesa Mount...

Страница 16: ...the light If light can easily be seen through the filter it can be used for another 30 days 5 Replace grill by carefully hinging on to the bottom of the housing first and snapping it into place on the...

Страница 17: ...17 Page 14 Filter Replacement and Reset Procedure cont Fig 1A...

Страница 18: ...18 Page 15 Filter Replacement and Reset Procedure cont Fig 1B...

Страница 19: ...river loosen and remove all four screws that secure the exhaust grill in place as shown in Fig 1D 5 The end of the plasma chamber tube will be exposed once the grill is removed Grasp the end of the tu...

Страница 20: ...20 Page 17 Plasma Chamber Replacement Process cont Plasma Chamber Exhaust Grill Fig 1C Fig 1D Exhaust Grill Screws...

Страница 21: ...21 Page 18 Plasma Chamber Replacement Process cont Fig 1E Plasma Chamber Contacts...

Страница 22: ...22 Page 19 Plasma Chamber Replacement Process cont Fig 1F Tab...

Страница 23: ...red on press the Fault Indicator to reset the display mode Q What should I do if the Active Indicator is illuminated RED A Check the LCD on the front of the unit This will display the issue with the u...

Страница 24: ...ere is the CID 75k manufactured A The CID 75k is manufactured at two locations 1 The AIRPHX Technical Operations Center in Cary NC It is an EPA registered establishment No 94099 NC 1 and 2 Nu Way Indu...

Страница 25: ...AND PROPERLY NOTIFY AIRPHX IN WRITING OR BY FAX WILL RESULT IN NULLIFICATION OF THIS WARRANTY ANY PARTS REPAIRS MODIFICATION AND OR MAINTENANCE SUPPLIED BY A NON AIRPHX REPRESENTATIVE OTHER THAN AIRPH...

Страница 26: ...irs performed on AIRPHX equipment missing a serial number or with a serial tag that has been altered or defaced 3 Service calls to correct installation of the equipment or instruct the owners on how t...

Страница 27: ...XPRESS WARRANTY SET FORTH ABOVE FAILS IN ITS ESSENTIAL PURPOSE Exclusive Remedies For any product described above that fails to conform to its warranty an AIRPHX representative will exclusively provid...

Отзывы: