background image

12

IO-123114 Effective 12-04-2014

20. Wiring diagram for 00-10 kW heating GAT & GAS models

HIGH VOL

TAGE disconnect all power sources prior to ser

vicing. Failure might lead to safet

y hazard

NOTES :

1.  LINE SPLICE TO BE ATTACHED TO UN USED

MOTOR LEAD. RD - LOW

 , BL - MED, BK - HI

2.  RED W

IRE TO BE ON TERMINAL 1 FOR 230 VOLT

OR TERMINAL 2 FOR 208 VOLT OPERATION.

W

IRING 

CODE

FACTORY

 LOW

 VOLT

FIELD HIGH VOLT

FIELD LOW

 VOLT

FACTORY

 HIGH VOLT

DIAGRAM

 # 

101

074

EQ

UI

PME

NT

 GROU

ND

BK

RD

1

2

3

4

5

6

7

9

BK

RD

LC

HE

AT

ER

 2

LC

HE

AT

ER

 1

SE

QUE

NC

ER

BK

RD

RD

W

H

BR

RD

RD

BK
BK

BK

BK

RD

RD

GR

RD

RD

MP

GR

BR

W

H

BK

CIRCUIT

 BRE

AK

ER

POW

ER 

SUP

PLY

USE

 COPP

ER

OR

THE E

QUIVA

LENT

SE

E RA

TING PLAT

E

HCS-03

HCS-04

HCS-08

1

2

3

FC

EM

BTD

HTR 1

HTR 2

LC

R

HS

BTD

WH

GN

BR

TRANSFORM

ER

24 

 VOLT

S

HTR 3

BK

CB

CB

LC

LC

HS

LO SPE

ED

(CAPP

ED)

M

ED S

PE

ED

(CAPP

ED)

HS

HS

BL

OW

ER M

OTOR 

SP

EE

D SE

TTING 

FOR M

AX

 KW

 RATING

UNIT MODEL

MA

X

KW

S

PE

ED

TAP

EL

ECTRIC HEAT

ONLY

EL

ECTRIC HEAT & HEAT 

PUM

P

MA

X

KW

S

PE

ED

TAP

GA

/ G

AT 1

8

GA

/ G

AT 2

4

06 06

LO HI

06 06

LO HI

TABLE 1

CU

RR

ENT 06161

4

20

8-2

40

 V

OL

TS

HCS-10

GA

/ G

AT 3

6

10

HI

10

HI

GA

/ G

AT 3

0

10

LO

10

LO

W

IRE 

HARNESS

12

70

35

12

70

32

 x

 2

COLOR CODE

LE

GE

ND

BTD CB BM FC FS

- BL

OW

ER TIM

DEL

AY

- CIRQUIT BREA

KE

R

- BL

OW

ER 

M

OTOR

- FAN CAP

ACITOR

- FEM

AL

SO

CKET

W BK BL RD B

K/W

GN GR BR GN/BK GN/RD

- W

HITE

- BLACK - BLUE - RED - BLACK/W

HITE 

STRIPE

- GREEN - GRAY - BROW

N

- GREEN/BLACK STRIPE - GREEN/RED STRIPE

LC HS HTR MP

- LI

M

IT CONTROL

- HEAT S

EQ

UENCER

- HEATE

R

- M

AL

PL

UG

2

1

3

5

4

SE

E  NOTE  2

8

SE

QUE

NC

ER

W

H

BR

W

BK

R

BR

GN

W

BK

1

2

3

4

5

6

7

8

9

BK

R

24V 

(HO

T)

FAN

ELEC

TR

IC

 H

EAT

EMER

G. H

EAT

24V

 (C

OM

)

R

BK

GN

BR

W

BK

W

R

CA

PA

CIT

O

R

BK

R

SE

NO

TE 

1 AN

TAB

LE

 1

GN

EV

AP

OR

AT

O

R

M

OTOR

3

2

1

5

4

24

V(COM

)

24

V

23

0V

20

8V

COM

SEE NOT

E 2

R

BR

GN

Содержание GAS Series

Страница 1: ...r service personnel CAUTION CAUTION WARNING WARNING WARNING WARNING WARNING WARNING GAT GAS Series Horizontal Ceiling Mount Electric Heat Dx Cool Air Handler 2 Introduction The GAT GAS Series air hand...

Страница 2: ...vel All main supply and return air drops should be properly size as deter mined by the designer of the duct system and should not necessarily be the size of the duct flange openings of the unit The dr...

Страница 3: ...burr free and clean Failure to do so may increase chances of a leak It is recommended to use a pipe cutter to remove the spun closed end of the suction line To reduce air leakage rubber gommets may b...

Страница 4: ...nstructions are separated into sec tions by metering device 2 A ducted return requires a non louvered panel 1 A bottom return installation requires a louvered panel 3 Both louvered and non louvered pa...

Страница 5: ...eflon O ring is located between the two halves of the flowrator CAUTION I 2 Replace the Teflon O ring located between the halves Discard Schrader if present During some installations a piston change m...

Страница 6: ...to install the right valve can lead to poor per formance and possible compressor damage CAUTION Ensure that the TXV bulb is in direct con tact with the suction vapor line Gap be tween the bulb and tub...

Страница 7: ...to the liquid line stub out See 8A I 3 Do not attempt to touch brazed joints while hot Severe burns may result WARNING III 3 After ensuring that the Teflon O ring seal is still in place inside the flo...

Страница 8: ...connections using proper brazing pro cedures 9 When all line connections are brazed perform a proper system evacuation procedure per the outdoor unit manufacturer instructions 10 Seal the penetration...

Страница 9: ...t 42 61 S Small Cabinet 18 36 Heat Strip 00 NO Heat BLOWER DATA UNIT MODEL RPM AMP VOLT HP CFM VS STATIC PRESSURE 0 00 0 10 0 20 0 30 0 40 GAT 18 1625 1 4 240 1 4 850 775 700 675 600 GAT 24 1000 900 8...

Страница 10: ...ssure measuring device 0 1 0 in slope gauge and a tempera ture measuring device 0 200 F thermometer 3 Release system charge from outdoor unit and call for cooling 4 Use outdoor unit equipment manufact...

Страница 11: ...are so that you may cut off the flow of energy in the event of overheating WARNING optimum equipment efficiency and performance Inspect and clean or replace filters every month This routine maintenanc...

Страница 12: ...MER 24 VOLTS HTR 3 BK CB CB LC LC HS LO SPEED CAPPED MED SPEED CAPPED HS HS BLOWER MOTOR SPEED SETTING FOR MAX KW RATING UNIT MODEL MAX KW SPEED TAP ELECTRIC HEAT ONLY ELECTRIC HEAT HEAT PUMP MAX KW S...

Страница 13: ...IO 123114 Effective 12 04 2014 13...

Страница 14: ...Atascocita Rd Humble TX 77396 Phone 281 441 6500 Toll Free 800 423 9007 Fax 281 441 6510 www airmark ac com Copyright 2014 AirMark All Rights Reserved Revised 12 04 2014 Subject to change without not...

Отзывы: