IMPORTANT
Before removing and/or returning an “Out of Range” transducer, please contact your service representative for additional product support.
4
Страница 1: ...TDT1000 D 17 615 01 rev 4 17 615 01 rev 4 09 23 20 Transducer Diagnostic Tester Owner s Guide...
Страница 2: ...tronic or printed copy of this manual or revision must contain the complete text of this copyright notice and provided further that any unauthorized commercial distribution of this manual or any revis...
Страница 3: ...5 Introduction 5 Kit Includes 6 Test Cables 7 Where to Purchase Cables 7 Test Set up 8 TDT1000 Set up 10 Connecting a Transducer 11 About Airmar s SensorCheck App 15 Troubleshooting 16 Replacement Pa...
Страница 4: ...IMPORTANT Before removing and or returning an Out of Range transducer please contact your service representative for additional product support 4...
Страница 5: ...s fire hazard if damaged defective or improperly used Exposure to liquids especially saltwater can cause internal corrosion damage to the cells or to the battery management system Batteries should be...
Страница 6: ...rope Test Cable with breakout box for transducers with NO connector Test Block Carrying Case Owner s guides The detailed Owner s Guide can be found at www airmar com tdt1000 The SensorCheck app guide...
Страница 7: ...B LR connector 33 1333 01 Lowrance Conventional Test Cable 7FB LR connector 33 1332 01 Mix Match Test Cable 1kW 9F A connector 33 1323 01 Mix Match Test Cable 600W 5F A connector 33 1389 01 Mix Match...
Страница 8: ...y become permanently deformed Always remove the transducer clean the Test Block and store it in a safe place Good Test Using the TDT Test Block in Air The Test Block simulates 1 to 2m 3 to 6 of water...
Страница 9: ...the Test Block by 2 5cm 1 3 Carefully place the acoustic face of the transducer onto the Test Block 4 Gently move the transducer from side to side to fully wet its acoustic face Be careful not to agi...
Страница 10: ...ector on the charging cable into the power adapter Figure 3 2 Plug the power adapter into a power supply 3 Plug the micro USB connector on the charging cable into the USB port on the TDT1000 4 When th...
Страница 11: ...have the correct test cable Many cables look alike or have the same connector Always use the SensorCheck app to determine the correct test cable 1 Open the SensorCheck app 2 Select the three horizonta...
Страница 12: ...there are some exceptions that are not evident when using the transducer Best practice is to connect a Mix Match transducer using the dedicated Mix Match TDT1000 Test Cable rather than connecting the...
Страница 13: ...ect it 3 Plug the transducer connector into the test cable Figure 7 4 Plug the test cable into the test cable port on the TDT1000 Twist and lock the connector Figure 6 Test cable with yellow tag Copyr...
Страница 14: ...esponding terminals in the breakout box If the test results do not look correct try swapping the solid and striped pairs and testing again Transducers built for OEMs can have different wire color codi...
Страница 15: ...ith the test set up or the instrument Do NOT remove return the transducer Contact your customer service representative To summarize information about a transducer and the vessel in which it is install...
Страница 16: ...ith breakout box for transducers with NO connector 33 736 01 Carrying Case ACC TDT1000 CASE Quick Start Guide 17 632 01 Owner s Guide can be found at www airmar com tdt1000 17 615 01 SensorCheck app g...
Страница 17: ...35 Meadowbrook Drive Milford New Hampshire 03055 4613 USA www airmar com...