Understanding Tip Number
The last three digits of tip number contain information about hole size and fan width on surface when gun is
held 12 in. (30.5 cm) from surface being sprayed
.
Last two digits = tip hole size in thousands of an inch
Reversible Tip Selection Chart
Fan Width - Inches
Orifice Size
(inches)
4
”
–
6
”
Fan
6
”
–
8
”
Fan
8
”
–
10
”
Fan
10
”
–
12
”
Fan
12
”
–
14
”
Fan
Flow Rate (gpm)
Application
.011
”
211
311
411
0.12
.013
”
213
313
413
513
613
0.16
Stain or Lacquer
.015
”
215
315
415
515
615
0.22
Oil Base Paint
.017
”
217
317
417
517
617
0.25
.019
”
219
319
419
519
619
0.33
.021
”
321
421
521
621
0.41
Latex Paint
/Acrylic/Enamel.
.023
”
523
623
0.49
.025
”
525
625
0.57
Heavy Latex
Important things to know about tip wear
It's important to replace a tip when it becomes worn, this ensures you''ll have a precise spray pattern,
maximum productivity and a quality finish. When tip wears, the hole(orifice) size increases and spray
pattern width decreases.
Tip life varies by coating, Extend tip life by spraying at the lowest
pressure that breaks up(atomizes)the coating into a complete
spray pattern.
Recommend tip replacement