AirKing ESDQ Series Скачать руководство пользователя страница 4

CAUTION: 

ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL 

OR ROOF CAP.

SECTION 8

Finishing the Installation

1.  Reinstall the bottom cover removed in Section 1 using the 4 screws to secure it in place.

2.  Reinstall the filters by fitting them into the channel on either side of the hood and 

pushing upwards on them until they are secured in place 

(Figure 11).

3.  Install the included 26 watt fluorescent lamp into the lamp holder by lining up the 

pins on the lamp base to the socket of the lamp holder and gently turning clock-

wise until the lamp snaps into place and is firmly seated in the lamp holder. Install 

a 4 watt maximum type C7 (candelabra base) night light (not included) into the side 

lamp holder and reinstall the lamp cover by squeezing the cover’s sides and fitting 

them into the slots on the hood.

4.  Turn switches to the “OFF” position and restore power. Test that the light and the 

fan are operating properly.

5.  If there is any vibration noise, check for the source and try to tighten fasteners or 

adjust the tape to make a tighter connection or seal.

SECTION 9

Controls

Your Range Hood is equipped with two rotary switches with one controlling the lighting and 

the other controlling the exhaust fan. The light switch has three positions, Main Light ( 

 ), 

Night Light ( 

 ), and OFF ( 

 ). The fan switch has four positions, High, Medium, Low, and OFF.

www.airkinglimited.com

5084457 Rev. G 1-11

4 of 12

SECTION 10

Maintenance

CAUTION: 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE SERVICING THE UNIT.

Filters

1. 

Grease Filter

 - Included with your range hood are aluminum grease filters that 

should be washed at least once a month. The filters are dishwasher safe and 

should be washed in a mild soap or detergent. Reverse the instructions in the 

“Finishing the Installation” section of the instructions to remove filters. If the grease 

filters become damaged, replace with Air King Model GF-01 Grease Filters.

2. 

Charcoal Odor Filter

 - If you have installed the optional charcoal odor filters, they 

cannot be washed and must be discarded and replaced when they become notice-

ably dirty, have stopped filtering the odors, or at least once per year. Replace with 

Air King Model CF-01 Odor Filters.

Changing the Lamp

1.  Remove the lamp cover by squeezing in the sides. The cover is held in place by 

tension against the tabs on the hood.

 

Fluorescent Lamp:

 Remove lamp by gently twisting counterclockwise to release 

the lamp from the base. Installation is the reverse of removal. Replace with Air King 

model 26SBL or a compatible 26W GU24 lamp.

 

Night Light:

 Unscrew night light bulb from socket and replace with a 4 watt maximum 

type C7 (candelabra base) night light bulb.

Fuse

1.  To replace the fuse, turn the fuse cap located next to the wire connector counter 

clockwise and pull out. Replace with only a 125-Volt fuse, 1-1/2 Amp Max. Reinstall 

the fuse back into the hood 

(Figure 7).

  

Cleaning

CAUTION:

 DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, 

ETC., AS THEY MAY DAMAGE THE RANGE HOOD.

1.  Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with 

a soft cloth. 

NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS

. Completely 

dry before restoring power. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

2.  The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates 

over time. The fan is permanently lubricated and does not require oiling.

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Hood does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Wiring is not connected properly. 

1b.  Turn off power to unit. Check that all wires are connected.

  2.  Hood is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting including filter.

  3.  Hood is making a rattling noise. 

3a.  Filters are loose. 

3a.  Turn off power to unit. Check that all filter are securely in place.

     

3b.  Duct connection is loose. 

3b.  Turn off power to unit. Check that duct connection is tight.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

Channel

Figure 11

Содержание ESDQ Series

Страница 1: ...g do not damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS...

Страница 2: ...re the strips line up to the keyhole slots of the range hood SECTION 3 Prepare the Hood for Installation 1 Choose the type of ducting you will require This model is equipped to vent either Vertically...

Страница 3: ...the two loose White wire from the range hood to the White wire from the supply and the loose Black wire from the range hood to the Black wire of the supply Connect the ground wire green or bare from t...

Страница 4: ...lled the optional charcoal odor filters they cannot be washed and must be discarded and replaced when they become notice ably dirty have stopped filtering the odors or at least once per year Replace w...

Страница 5: ...S AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES...

Страница 6: ...3 15 2 Air Inlet Collar 5S1111023 16 1 Blower Housing 5S1111024 17 1 Twin Blower Wheel L 5S1111025 18 4 8 32 Screw 5S1999003 19 2 Motor Mounting Bracket 5S1111027 20 1 Motor 5S1111028 21 1 Twin Blower...

Страница 7: ...US D VACUER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent toujo...

Страница 8: ...minez le type de conduits dont vous aurez besoin Ce mod le peut vacuer l air verticalement ou horizontalement par un conduit de 8 25 cm sur 25 4 cm On peut galement l utiliser sans vacuation il rejett...

Страница 9: ...de la hotte au c ble noir de l alimentation Branchez le fil de mise la terre vert ou d nud du bloc d alimentation la vis de mise la terre verte de la hotte Suivez les m thodes homologu es pour effect...

Страница 10: ...s les odeurs ou qu ils ont un an d usure vous devez les jeter et vous en procurer des nouveaux Remplacez les par les filtres odeurs Air King de mod le CF 01 Changement de la lampe 1 Retirez l cran pro...

Страница 11: ...SSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES...

Страница 12: ...entr e d air 5S1111023 16 1 Bo tier du ventilateur 5S1111024 17 1 Roue du ventilateur double gauche 5S1111025 18 4 Vis n 8 32 5S1999003 19 2 Support du moteur 5S1111027 20 1 Moteur 5S1111028 21 1 Rou...

Отзывы: