INSTALLATION INSTRUCTIONS
CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Range Hood

1.  Unpack hood from the carton and confirm that all pieces are present. In addition to 

the range hood you should have:

 

 

2 - Aluminum Grease Filters

 

 

1 - 3-1/4"x 10" Damper

 

 

3 - Damper Mounting Screws

 

 

4 - #8 Mounting Screws

 

 

1 - GU24 Base, 26W Fluorescent Lamp

 

 

1 - Instruction/Safety Sheet      

NOTE:

 Some hoods may be shipped with a protective plastic adhered to the range 

hood. It is recommended to leave this in place during installation to protect the hood 

from scratching. Remove when the installation is complete.

2.  Lay the hood flat on a table so the underside is facing you. Use a piece of cardboard 

to avoid damaging the table or the hood.

3.  Remove the following items from the hood and place in a safe place until needed 

(Figure 1):

 

Grease filters:

 Pull on tabs to remove.

 

Bottom cover:

 Remove the 4 screws holding it in place.

 

Lamp cover:

 Squeeze in the sides. The cover is held in place by tension against the 

tabs on the hood.

 

Wire compartment cover:

 Remove the screw holding it in place.

 

Blower:

 Using a 3/8" nut driver or ratchet, remove the 4 nuts holding the blower in place.

SECTION 2

Prepare the location for Hood Support

1.  If the hood will be installed under cabinets that have a recessed bottom, it will be 

necessary to install wood mounting strips (not included) so the hood will mount 

properly 

(Figure 2).

www.airkinglimited.com

5084457 Rev. G 1-11

2 of 12

2.  The thickness of the strips should be the same as the recess of the cabinet and 

they should be approximately 2" wide.

3.  Install the strips using appropriate length wood screws (not included). Make sure 

the strips line up to the keyhole slots of the range hood.

SECTION 3

Prepare the Hood for Installation

1.  Choose the type of ducting you will require. This model is equipped to vent either 

Vertically or Horizontally through a 3-1/4" x 10" duct. It can be modified to be duct-

less (re-circulates the air back into the kitchen) with the addition of 2 models CF-01 

Charcoal Filters (not included) 

(Figure 3).

2a. 

Horizontal or Vertical

 - Remove the apprpriate square knockout by inserting a 

screw driver under the edge and break the tabs holding it in place. Peel back with 

pliers 

(Figure 4).

2b. 

Ductless

 - Lift up and remove the hood’s vent insert located behind the grill, exposing 

the front air slots. Do not use a screwdriver or any other object that could scratch the 

hood 

(Figure 4).

3.  Determine where the electrical service will enter the hood and remove the appropriate 

electrical knockout by inserting a screw driver into the slot and rocking back and forth 

until the knockout comes loose 

(Figure 4).

4.  Once the proper knockout(s) have been removed, either hold the hood up to the 

installation location and mark the locations of the ducting, electrical, and mounting 

holes or mark the locations by measurement.

5.  Cut appropriate holes for ducting connection and electrical connection in the 

wall/cabinet.

6.  For 3-1/4" x 10" vertical or horizontal ducting, install the damper assembly to the hood 

by sliding the tabbed section of the damper under the hood body and securing with 

the two provided screws 

(Figure 5).

7.  Install an approved wire connector to the electrical knockout of the hood and guide 

the electrical cable through the hood, allowing at least 6" of wire for connections 

and tighten.

Figure 1

Lamp Cover

Motor

Bottom

Cover

Wire

Compartment

Cover

Grease 

Filter Tab

Figure 2

Wood Strip

Figure 3

Vertical

Ductless

Horizontal

Figure 4

Vertical

Ductless

Horizontal

Damper

Hood

Body

Tab

Figure 5

Содержание ESDQ Series

Страница 1: ...g do not damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS...

Страница 2: ...re the strips line up to the keyhole slots of the range hood SECTION 3 Prepare the Hood for Installation 1 Choose the type of ducting you will require This model is equipped to vent either Vertically...

Страница 3: ...the two loose White wire from the range hood to the White wire from the supply and the loose Black wire from the range hood to the Black wire of the supply Connect the ground wire green or bare from t...

Страница 4: ...lled the optional charcoal odor filters they cannot be washed and must be discarded and replaced when they become notice ably dirty have stopped filtering the odors or at least once per year Replace w...

Страница 5: ...S AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES...

Страница 6: ...3 15 2 Air Inlet Collar 5S1111023 16 1 Blower Housing 5S1111024 17 1 Twin Blower Wheel L 5S1111025 18 4 8 32 Screw 5S1999003 19 2 Motor Mounting Bracket 5S1111027 20 1 Motor 5S1111028 21 1 Twin Blower...

Страница 7: ...US D VACUER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent toujo...

Страница 8: ...minez le type de conduits dont vous aurez besoin Ce mod le peut vacuer l air verticalement ou horizontalement par un conduit de 8 25 cm sur 25 4 cm On peut galement l utiliser sans vacuation il rejett...

Страница 9: ...de la hotte au c ble noir de l alimentation Branchez le fil de mise la terre vert ou d nud du bloc d alimentation la vis de mise la terre verte de la hotte Suivez les m thodes homologu es pour effect...

Страница 10: ...s les odeurs ou qu ils ont un an d usure vous devez les jeter et vous en procurer des nouveaux Remplacez les par les filtres odeurs Air King de mod le CF 01 Changement de la lampe 1 Retirez l cran pro...

Страница 11: ...SSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES...

Страница 12: ...entr e d air 5S1111023 16 1 Bo tier du ventilateur 5S1111024 17 1 Roue du ventilateur double gauche 5S1111025 18 4 Vis n 8 32 5S1999003 19 2 Support du moteur 5S1111027 20 1 Moteur 5S1111028 21 1 Rou...

Отзывы: