Anti-Back draught Flap 

All models (with the exception of dMEV model) 
Are supplied with an anti-back draught flap 
accessory as shown in Figure 14. If required, this 
assembly may be fitted to the spigot of the fan as 
shown in Figure 15. Note: the hinge of the flap 
must always be vertical as in Figure 15 for 
correct operation. This accessory is not 
recommended for ceiling mounted applications. 
Use of the flap will cause a slight reduction to the 
rated output of the fan. An external gravity flap 
grille may be used if required. (optional 

–  

Airflow Part #51791101) 

 

Restrictor Cone 

The Continuous Ventilation dMEV model is  
Supplied with a restrictor cone to increase the 
air velocity. This is supplied as a two part  
assembly (Figure 16) and should be clipped 
together and secured with adhesive tape (not 
included) to the spigot of the fan (Figure 17) The 
cone is only required in applications requiring a 
continuous trickle ventilation rate of 7/9 l/s 

–WC, 

En-Suite, Bathroom and Utility. (Normal 100mm 
ducting should still be connected to the fan 
spigot and not the cone outlet) The cone is not 
required for operation at 16 l/s. 

 

3. Electrical Installation 

All electrical installations should be carried out by an approved electrician in accordance with Part 
“P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the 
country of installation. The LOOVENT eco requires a 100-240V 50/60Hz supply and an external 3A 
fuse; it is double insulated so therefore does not require an earth.  For fans mounted in Zones 1 & 2 
as defined in section 701 BS7161:2008 additional protection must be provided by a Residual 
Current Detector (RCD) with a rated residual operating current not exceeding 30mA. An isolator 
switch should also be installed in the MAINS input line to facilitate maintenance and cleaning of the 
fan. 
Power connections are made through the terminal block as shown in Figure 18. Unplug the terminal 
block from the base of the fan module. Prepare the cable by leaving a length of 60mm protruding 
from inside the base of the fan. Strip the conductor insulation back by 5mm and connect to the 
terminal block as shown in Figure 20 or 22 on Page 6.  Once connections have been made, feed 
the cable back into the recess and clip the terminal block back into location as shown in Figure 19. 
The power connection is made automatically when the fan module (see Figure 1) is positioned into 
the unit and the two M4 retaining screws (see Figure 7) are tightened. 

 

 

 

 

 

 

Figure 14

 

Figure 15

 

Figure 16

 

Figure 17 

Tape 

Figure 18

 

Figure 19

 

Содержание LOOVENT eco T

Страница 1: ... SFP Compact design Longer life Ball Bearing Motor Simple replacement of existing Loovent Read before commencing installation Please leave these instructions for the occupier LOOVENT eco T Timer 72684305 LOOVENT eco HT Humidity Timer 72684306 LOOVENT eco MST Motion Sensor Timer 72684307 LOOVENT eco dMEV Continuous Ventilation 72684308 ...

Страница 2: ... remotely by means of a switched live connection from a light or door switch The dMEV model uses the switched live to initiate boost mode All models feature a momentary pull cord switch as a manual boost override no click will be heard when you pull this cord The fan has an ingress protection rating of IPx5 and is suitable for mounting in Zone 1 or 2 with a 30mA RCD as defined in Section 701 BS716...

Страница 3: ...d slightly and slide to the right to release from the two lugs in the base Figure 7 Recessing in the Wall The fan can be mounted landscape with the release buttons facing downwards or portrait with the buttons on the right hand edge The fan requires a 110mm diameter hole through the external wall lined with a 100mm internal diameter duct kit refer to Page 8 for accessories The internal wall requir...

Страница 4: ... the pull cord is stowed This also means the Timer and Motion Sensor Timer versions become single speed fans L or H which should be selected at installation depending on the requirement The Humidity and dMEV versions remain 2 speed as they are automatically boosted by the humidity sensor and remote switch respectively Refer to the Electrical Installation section for wiring instructions and fitting...

Страница 5: ...lations should be carried out by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation The LOOVENT eco requires a 100 240V 50 60Hz supply and an external 3A fuse it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS71...

Страница 6: ...LS AND CLEANING OF INTERNAL PARTS For safety This fan is fitted with a safety device which inhibits operation when the front cover is open However it is recommended that the fan is isolated from the power supply by switching the 3 pole isolator or 2 pole fused spur if the fan has no external switching before opening the front cover The fan must be isolated if the impeller module is to be removed e...

Страница 7: ...ed with the Delay Start Boost in the OFF position Intermittent setting the switch to ON applies a 2 minute delay to the low speed ideal for quick visits It does not delay the Pull Cord override function Continuous setting the switch to ON will delay the timer function on boost speed by 2 minutes where the boost is activated by a remote switch It does not delay the Pull Cord override function Note ...

Страница 8: ...nits for 3 YEARS from date of purchase against faulty material or workmanship Extended to 5 years when registered airflow com Warranty only covers the fan not the reinstallation of this if required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit 1 Has been installed and used in a...

Отзывы: