background image

 

 

Page 2 of 8 

 

 
 
 
 
 
 
 
Cover 

 
 
 
 
 
 
 
Fan 
Module 

 
 
 
 
 
 
 
Outer 
Casing 

Restrictor Cone 
(dMEV only) 

Cover 

Anti -
Backdraught 
Flap (T, HT, 
MST only) 

Outer 
Casing 

Fan 
Module 

 
1. Overview 

LOOVENT eco fans are available in various versions which can all be fitted to a ceiling or wall in 
either landscape or portrait orientation. The fan requires a suitable size hole through the wall or 
ceiling which connects to a duct venting to the outside. The external opening (100mm round hole) 
should be covered by a suitable grille, available separately from Airflow Developments Ltd. 
LOOVENT eco Functionality: 

INTERMITTENT VENTILATION 

  Timer -  17/31 l/s flow rate, boost  triggered by integral pull cord 

  Humidity/Timer - 17/31 l/s flow rate, automatic boost triggered by humidity sensor 

– override 

with integral pull cord 

  Motion Sensor/Timer - 17/31 l/s flow rate, boost triggered by an integral pull cord 

CONTINUOUS VENTILATION

 

  dMEV 

– 7/ 9/16 l/s flow rate, boost to 15/15/31 l/s triggered by remote switch /integral pull 

cord.  

 
All models are two speed with a selectable 2 minute delay start function and a run-on timer 
adjustable between 2 and 45 minutes. With the exception of the dMEV Fan, all fans can be 
triggered remotely by me

ans of a “switched live” connection from a light or door switch. The dMEV 

model uses the “switched live” to initiate boost mode. All models feature a momentary pull-cord 
switch as a manual “boost” override (no click will be heard when you pull this cord) 
 
The  fan has an ingress protection rating of IPx5 and is suitable for mounting in Zone 1 or 2 with a 
30mA RCD as defined in Section 701 BS7161:2008 (IEEE Wiring Regulations, Seventeenth 
Edition). The LOOVENT eco also complies with the latest Building Regulations, Approved 
Document F (Part L). 
 
LOOVENT eco requires a 100/240V-50/60Hz single phase supply. Class II equipment. BS EN 
60417.  An external 3A fuse is required for each fan unit. The product is fully compliant with the 
following safety standards: CE2004/105//EMC Directives and LVD 2006 195/EC. 
 

Note: 

Switches for fans should be selected and sited in accordance with BS7161:2008. 

Do  not  place  the  fan  near  direct  heat  sources,  e.g.  radiant  heaters,

 

above  cookers  or  where 

temperatures can exceed 40°C (104°F). 
All electrical installation should 

be carried out by an approved electrician in accordance with Part “P” 

U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the 
country of installation. 

For safety

: This fan is fitted with a safety device which inhibits operation when the front cover is 

open. 

 
 
 
 
 
 

 
 

 

 
 

 
 

Figure 1  

Содержание LOOVENT eco T

Страница 1: ... SFP Compact design Longer life Ball Bearing Motor Simple replacement of existing Loovent Read before commencing installation Please leave these instructions for the occupier LOOVENT eco T Timer 72684305 LOOVENT eco HT Humidity Timer 72684306 LOOVENT eco MST Motion Sensor Timer 72684307 LOOVENT eco dMEV Continuous Ventilation 72684308 ...

Страница 2: ... remotely by means of a switched live connection from a light or door switch The dMEV model uses the switched live to initiate boost mode All models feature a momentary pull cord switch as a manual boost override no click will be heard when you pull this cord The fan has an ingress protection rating of IPx5 and is suitable for mounting in Zone 1 or 2 with a 30mA RCD as defined in Section 701 BS716...

Страница 3: ...d slightly and slide to the right to release from the two lugs in the base Figure 7 Recessing in the Wall The fan can be mounted landscape with the release buttons facing downwards or portrait with the buttons on the right hand edge The fan requires a 110mm diameter hole through the external wall lined with a 100mm internal diameter duct kit refer to Page 8 for accessories The internal wall requir...

Страница 4: ... the pull cord is stowed This also means the Timer and Motion Sensor Timer versions become single speed fans L or H which should be selected at installation depending on the requirement The Humidity and dMEV versions remain 2 speed as they are automatically boosted by the humidity sensor and remote switch respectively Refer to the Electrical Installation section for wiring instructions and fitting...

Страница 5: ...lations should be carried out by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation The LOOVENT eco requires a 100 240V 50 60Hz supply and an external 3A fuse it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS71...

Страница 6: ...LS AND CLEANING OF INTERNAL PARTS For safety This fan is fitted with a safety device which inhibits operation when the front cover is open However it is recommended that the fan is isolated from the power supply by switching the 3 pole isolator or 2 pole fused spur if the fan has no external switching before opening the front cover The fan must be isolated if the impeller module is to be removed e...

Страница 7: ...ed with the Delay Start Boost in the OFF position Intermittent setting the switch to ON applies a 2 minute delay to the low speed ideal for quick visits It does not delay the Pull Cord override function Continuous setting the switch to ON will delay the timer function on boost speed by 2 minutes where the boost is activated by a remote switch It does not delay the Pull Cord override function Note ...

Страница 8: ...nits for 3 YEARS from date of purchase against faulty material or workmanship Extended to 5 years when registered airflow com Warranty only covers the fan not the reinstallation of this if required In the event of any defective parts being found Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit 1 Has been installed and used in a...

Отзывы: