4.0 Installation 

Section 4 contains information about the installation of the product into its intended area of 
operation. It contains information about the installation location, mobility, electrical 
connection, and unboxing. 
 

4.1 Unboxing 

The product will come in a cardboard box which can be disposed of and recycled. 

Ensure 

this manual is kept with the unit.

 The unit will not come upright, and it is not 

recommended the product is unboxed this way in case it may fall. Move the box to the 
intended location of install using a suitable means. If the unit is too heavy, use 2 people or 
suitable machinery such as a pallet mover. If for any reason, the box is damaged and 
preventing transport, consult section 1.2 and 1.5 of this document. In this case, the product 
may be removed from the box, upright it and wheel it to the desired location using the mobile 
wheels at the bottom of the unit.  
 

4.2 Installation Location 

The Purigo M 650/850 air purifiers must be placed in a vertical position in such a way that 
the air inlets and air outlets of the apparatus are not blocked by obstacles and a clear air 
distribution path is guaranteed. The unit is intended to be stood on its wheels. Do not seal 
the unit in place as the back will need to be accessed for maintenance. Do not put the unit in 
a location which will exceed its maximum temperature tolerances. Do not place the unit in 
areas which are to be kept clear for any reason, such as a fire exit. Allow easy access for 
adjustment of the potentiometer. Do not place the unit inside a cupboard, wardrobe, or 
cabinet. Do not rest heavy objects on the unit or use it to hold other objects in place. It is 
recommended to not place the unit where there is a danger of it falling from a great height. 
Do not place the unit in water or submerge it. Do not concrete the unit in place or install into 
a wall, floor or ceiling.  
 

4.3 Mobility 

The Purigo M series has wheels at the base of the unit which allow free movement. These 
wheels can be locked by pressing down on the handles on the top of the wheels. When the 
unit is to be moved, unlock these wheels again. Do not attempt to move the unit when the 
wheels are locked.  
 

4.4 Electrical Connection 

The electrical connection is made by plugging in the power cable to the back of the unit and 
inserting the plug into a mains power socket. The black power switch on the back of the unit 
will turn power on and off. Do not run the electrical connection through water using a cable 
extender or any other cable. Ensure the plug and plug socket is safe and electrically secure 

BEFORE

 operation or plugging in the unit. Never attempt to force the wrong plug type into 

the power connection. Always check the plug is compatible with the product before 
attempting to install.  
 
 
 
 
 
 

Содержание 90001459

Страница 1: ...Installation operation and maintenance manual Part No 90001459 90001460 Purigo M650 M850 Please keep this manual with the product ...

Страница 2: ...Filter Disposal 5 2 2 Electrical Connection 5 2 3 Recycling 5 3 0 Technical Information 6 4 0 Installation 8 4 1 Unboxing 8 4 2 Installation Location 8 4 3 Mobility 8 4 4 Electrical Connection 8 5 0 Operation 9 5 1 Operating the Power 9 5 2 Speed Control 9 6 0 Maintenance and Service 10 6 1 Important safety information 10 6 2 Maintenance Schedule 11 6 3 Components 11 6 3 Filters 12 Notes Error Boo...

Страница 3: ...small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and from slipping on slippery surfaces Danger Always pay close attention to danger and warnings signs To not do so could cause serious personal injury deat...

Страница 4: ...esigned to be used in a typical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and removing the small particles dust pollen bacteria and viruses with the help of air filters Any use other than the intended use is prohibited Do not use the unit at a relativel...

Страница 5: ...contractor must ensure that the components are separated according to material type 2 1 Filter Disposal The filters of the unit can be considered toxic and harmful to the environment once they are due for replacement Please dispose of these in the most appropriate manner to the local authority 2 2 Electrical Connection The product does not contain batteries in the event of the failure of the unit ...

Страница 6: ... consumption W 170 170 Max power consumption A 1 7 1 7 Voltage V 230 50 60 230 50 60 Filters HEPA H14 H14 Filters EPM ePM10 70 ePM10 70 Table 3 Technical Specification Specification M850 M650 Airflow Volume min m3 h 160 100 Airflow Volume max m3 h 850 650 Max covering area m2 71 54 Sound Power Min dBa 34 35 Sound Power Max dBa 66 69 Acoustic Pressure min dBa 1m 26 27 Acoustic Pressure at Max dBa 1...

Страница 7: ...54 97 75 700 768 56 125 80 768 815 57 149 85 815 830 57 160 90 830 844 58 168 95 844 844 58 168 100 844 844 58 168 Table 5 M650 Setting levels M650 Adjustment levels Air Volumes m3 h Noise level at 1m dBa Power W 20 0 90 27 4 25 90 140 32 6 30 140 180 37 8 35 180 200 39 12 40 200 270 43 17 45 270 310 46 24 50 310 350 48 32 55 350 400 51 44 60 400 460 53 59 65 460 490 55 74 70 490 535 57 93 75 535 ...

Страница 8: ...nce Do not put the unit in a location which will exceed its maximum temperature tolerances Do not place the unit in areas which are to be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit or use it to hold other objects in place It is recommended to no...

Страница 9: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfort is intended to be the everyday operating speeds and boost for short periods of increased purification Danger Danger to life due to electric shock An electric shock can result in death or serious inju...

Страница 10: ...cts the airways from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and from slipping on slippery surfaces Danger Danger to life due to electric shock An electric shock can result in death or serious in...

Страница 11: ...eck for unacceptable levels of dirt odours and damage Replace the filter X Check the filter change indicator next to adjustment knob Replace the filter X Fan Check for pollution shading and corrosion damage Clean or replace the fan X Check for abrasion or unbalance Change the fan X Check internal fan connection cable Repair or replace X Silencer Check for dirt and damage Clean or change X 6 3 Comp...

Страница 12: ...ay not perform as intended Device Filter Classes Filter QTY Filter Dimensions Ref No Purigo M650 Epm10 70 1 305x305x100 90001513 HEPA 14 1 305x305x292 90001514 Purigo M850 Epm10 70 1 305x305x100 90001515 HEPA 14 1 305x305x292 90001516 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Remove the back cover unscrewing it wit...

Страница 13: ...ow Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyright 2016 Airflow Developments Ltd ...

Отзывы: