background image

Uno hab Ext. Wall Ins. Vent Kit

Installation and Operating Instructions

6

© Airflow

 

-

 

we reserve the right to make changes without prior notice

3.0  Scope of delivery

Leave the installation kit facia in its packaging until just before the respective installation step or installation in order 

to prevent any possible damage and contamination.

Uno hab

 Wall installation vent kit

 Part No: 90001002

ò

Wall installation sleeve

plastic: Length = 500 mm

ù

EPP front wedge

– for condensate drain
– with labelling “middle bottom”

ä

EPP soffit channel

ë

EPP plaster frame

ö

Condensate discharge plate

ü

Wall grille (incl. seal for wall connection)

Å

Fixing material

2x Insulation fixing
2x Stainless steel screw (Ø 4,5 x 50 mm)
4x Stainless steel screw (Ø 5 x 100 mm)
4x Stainless steel screw (Ø 6,4 mm)

î

Protective cover

2x for inside and outside

Ø

EPP fixing wedges

3.1  Dimensions 

fig.1

CHAPTER 3 

SCOPE OF DELIVERY

Wall installation vent kit

fig.2

Provided components

ë

ö

Fig.2

Enclosed components

î

Ø

All dimensions in mm

Fig.3

ä

ò

ù

ü

Å

ë ö

 100 

 324 

 20 - 35 

 324 

 74 

 74 

 120 

 360 

 5 

 500 

(adjustable to 300 

mm )

 120 

 180 

 320 

 300 

 320 

 0 - 280 

(adjustable area)

180

Содержание 8QRKDE

Страница 1: ...t Kit Installation and Operating Instructions Airflow we reserve the right to make changes without prior notice External wall insulation vent kit 8QR KDE WHUQDO ZDOO LQVXODWLRQ YHQW NLW INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ... Contr oller kit Unoh ab CTRL kit flush Part No 90000994 Uno hab CTRL kit DIN rail Part No 90000995 Switching power supply Uno hab PSF Part No 90000996 included in Uno hab CTRL SET Uno hab PSD Part No 90000996 included in Uno hab CTRL DIN MAX 8 units Attention if necessary additional power supply required Output 12 V control line Output 12 V control line Input 230 V optional Additional power suppl...

Страница 3: ...on of liability Page 5 2 1 Certificates Guidelines Page 5 2 2 Shipping Page 5 2 3 Receipt Page 5 2 4 Driving rain impermeability of the stainless steel wall grille Page 5 2 5 Limits of use stainless steel Page 5 CHAPTER 3 SCOPE OF DELIVERY Page 6 3 0 Scope of delivery Page 6 3 1 Dimensions Page 6 CHAPTER 4 POSITIONING ASSEMBLY Page 74 0 Installation overview soffit element Page 7 4 1 Positioning c...

Страница 4: ...unit Depending on the overall ventilation requirement of the residential unit more than 2 units are normally installed and the individual volume flows are automatically adjusted by means of the central control unit The standard equipment allows installation and use in frost free rooms 5 C When operating under difficult conditions such as high levels of humidity long standstill periods excessive lo...

Страница 5: ... in the original packaging 2 3 Receipt The shipment Uno hab Ext Wall Ins Vent Kit part number 90001002 must be checked for damage and correctness immediately upon delivery If there is any damage promptly report the damage with the assistance of the transport company If complaints are not made within the agreed period any claims could be lost 2 4 Driving rain impermeability of the stainless steel w...

Страница 6: ...with labelling middle bottom ä EPP soffit channel ë EPP plaster frame ö Condensate discharge plate ü Wall grille incl seal for wall connection Å Fixing material 2x Insulation fixing 2x Stainless steel screw Ø 4 5 x 50 mm 4x Stainless steel screw Ø 5 x 100 mm 4x Stainless steel screw Ø 6 4 mm î Protective cover 2x for inside and outside Ø EPP fixing wedges 3 1 Dimensions fig 1 CHAPTER 3 SCOPE OF DE...

Страница 7: ...rail ù Immersion depth of the wall installation sleeve in the soffit element Length 20 mm m NOTE The wall installation sleeve must not be cut off flush with the wall on the outside ä Soffit channel feet Max 40 mm Min 0 mm The soffit channel feet determine how far it sits from the uncovered wall The height of the feet and the height of the soffit channel of 100 mm corresponds to the min insulation ...

Страница 8: ... with gradient to outside is required for the unit installation or Ø 172 mm horizontal with condensate wedge Include the empty conduit for the electr control cable in the installation wall NOTE The empty conduit must be placed below the unit installation position 1 Determine the position of the core drilling hole for the soffit element see Fig 6 2 Execute core drilling 3 Provide empty conduit for ...

Страница 9: ...ll annular gap inside and outside with non pressurised installation foam Fig 9 10 9 After a sufficient drying time remove the protruding fixing wedges and excess installation foam If necessary remove EPP material lower front wedge and any installation foam residue for cable entry Fig 9 10 Create diffusion tight seal on annular gap Fig 10 11 Place protective cover on the wall installation sleeve In...

Страница 10: ...ore drilling points for the soffit channel and remove the soffit channel 6 Drill the drilling holes and insert dowels not included 7 Connect soffit channel to the wall sleeve and screw in Fig 13 washers and screws are included 8 Apply thin glue sealing beads to the plaster frame Fig 14 9 Connect plaster frame to the soffit element and screw in with the enclosed insulation fixings Fig 14 15 10 Back...

Страница 11: ...thout prior notice 11 Attach surrounding insulation panels Fig 16 12 Attach any plaster corner rails 13 Plaster the soffit channel and plaster frame 14 Remove any protruding plaster frame with multitool Fig 17 15 Insert condensate pan Fig 18 16 Mount wall grille Fig 19 The screws are included Fig 18 Fig 19 Fig 16 Fig 17 ...

Страница 12: ...g periods condensation can form in the heat accumulator due to the process of heat recovery The condensation water must be able to drain from the unit A condensate drain gradient of 1 2 is ensured during installation by the EPP front wedge which is pre mounted to the wall installation sleeve TheprotrusionofthecondensatedraininthelowerEPPhalfshellallowsfreecondensatedrainageinthesoffitchannel from ...

Страница 13: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 13 Airflow we reserve the right to make changes without prior notice Notes ...

Страница 14: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 14 Airflow we reserve the right to make changes without prior notice Notes ...

Страница 15: ...Uno hab Ext Wall Ins Vent Kit Installation and Operating Instructions 15 Airflow we reserve the right to make changes without prior notice Notes ...

Страница 16: ...cations without prior notice All orders are accepted subject to our conditions of sale which are available on request Certificate No EMS 569454 BS EN 1SO 14001 2015 Certificate No FM 00152 BS EN 1SO 9001 2015 Airflow Developments Limited Aidelle House Lancaster Road Cressex Business Park High Wycombe Buckinghamshire United Kingdom HP12 3QP Call 01494 525252 Visit airflow com 80000782 Issue 2 09 20...

Отзывы: