AIRFLO AFS140 Скачать руководство пользователя страница 7

8. Allow to stand for at least 40 minutes, or more if possible. 
9. Drain vinegar from Boiler. 
10. Rinse Boiler with fresh water, drain and repeat until vinegar odor dissipates. 
11.  Loosely replace Boiler Cap and continue with normal storage procedure, as outlined in 

PROPER STORAGE

 section above. 

Troubleshooting

 

PROBLEM

 

POSSIBLE CAUSE

 

SOLUTION 

Unit fails to heat up.    Heating 

Indicator Light  DOES NOT 

illuminate. 

Unit is not plugged in. 

Plug  power  cord  into  electrical 

outlet. 

Household circuit breaker / ground 

fault interrupter has tripped or 

blown a fuse. 

Reset circuit breaker / ground fault 

interrupter, or replace fuse.  For 

assistance, contact a licensed 

electrician. 

Unit is damaged or otherwise in 

need of repair. 

Immediately cease usage and unplug 

Contact manufacturer. 

Unit fails to heat up.    Heating 

Indicator Light 

DOES 

illuminate. NOTE: Always allow 

sufficient

 time for unit to heat 

up before  pressing Steam 

Trigger. 

No water in Boiler. 

Refer to  FILLING BOILER  procedure   

to fill unit with water.

 

Mineral build-up in unit. 

Refer to  CARE & MAINTENANCE 

section for details. 

Unit is damaged or otherwise in 

need of repair. 

Immediately cease usage and 

unplug.    Contact manufacturer. 

Steam output is weak or 

intermittent. 

Water level in Boiler is running low. 

Refer to  FILLING BOILER  procedure 

to refill unit with water.

 

Mineral build-up in unit. 

Refer to  CARE & MAINTENANCE 

section for details. 

Boiler Cap cannot be 

unscrewed. 

Boiler  Cap has been overtightened 

after previous use. 

Boiler Cap should always be replaced 

loosely  when storing.  For 

assistance  with a Cap that has 

become stuck, contact manufacturer. 

 
 
 
 

 

 

 

Product specifications 

MODEL    JSL-210 

VOLTAGE    220-240VAC 50/60Hz 

WATTAGE    900W 

AMPERAGE

    3.9A 

WATER  CAPACITY

    6 OZ. (180 ML.) 

HEATING TIME   

3 MIN. (APPROXIMATE)

 

CONTINUOUS STEAM TIME   

8 MIN. (APPROXIMATE)

 

UNIT WEIGHT    2.8 LBS. (1.3 KG.) 

UNIT DIMENSIONS    13.3” (33.8 CM.) x 5.7” (14.4 CM.) x 8.3” (21.1 CM.) 

POWER 

CORD LENGTH  12.5’ (380.0 CM.) 

 

 

 

Содержание AFS140

Страница 1: ...e it is least likely to be damaged or tripped over during use 3 Before plugging power cord into electrical outlet be sure that all electrical information on rating label agrees with your power supply 4 To reduce likelihood of circuit overload DO NOT operate another high wattage appliance on the same circuit as this unit 5 To protect against risk of electrical shock do not immerse unit in water or ...

Страница 2: ...liance before each use by positioning it away from body and turning it on Do not operate unit if Steam Nozzle is blocked 16 Burns can occur from touching hot plastic parts hot water or steam Do not touch Steam Nozzle or attempt to connect any accessories while unit is in use Use caution when you turn Nozzle or attempt to connect any accessories while unit is in use 17 When steaming any surface for...

Страница 3: ...of steam for concentrated cleaning The Nylon Utility Brush Brass Utility Brush and Large Brush all connect to the Jet Nozzle Alternatively the Jet Nozzle may be connected to the end of the Extension Hose 8 The Nylon Utility Brush 8 connects to the Jet Nozzle and is designed for scrubbing especially tough stains The Nylon Utility Brush is ideal for use on many surfaces around the home including car...

Страница 4: ... its final position Guide keys on Jet Nozzle should line up with key slots on base of Steam Nozzle FIGURE 1 B FIGURE 1 2 Slide Jet Nozzle onto Steam Nozzle guide keys should fit into key slots Push Jet Nozzle on as far as it will go Rotate Jet Nozzle 90º clockwise turning it until it will move no further FIGURE 2 FIGURE 2 Connecting brushes NOTE The Nylon Utility Brush Brass Utility Brush and Large ...

Страница 5: ...taken when refilling the unit after it has been in use 4 Boiler should always be emptied after each use If it was not emptied after the previous use empty it before using This will make it easier to fill with the correct amount of water 5 Fill included Measuring Cup with 6 oz 180 ml of water NOTE In order to extend the life of your Hand Held Steamer and keep it functioning at its maximum potential i...

Страница 6: ...ny connected accessories approximately 1 2 inch from surface and press Steam Trigger Keep Trigger pressed and concentrate steam on the same spot for at least 5 seconds 6 At its maximum capacity 6 oz 180 ml the Boiler will provide approximately 8 minutes of continuous steam If you wish to continue steaming refer to FILLING BOILER procedure Be sure to note Refilling Boiler section at bottom of page 7...

Страница 7: ...sufficient time for unit to heat up before pressing Steam Trigger No water in Boiler Refer to FILLING BOILER procedure to fill unit with water Mineral build up in unit Refer to CARE MAINTENANCE section for details Unit is damaged or otherwise in need of repair Immediately cease usage and unplug Contact manufacturer Steam output is weak or intermittent Water level in Boiler is running low Refer to FI...

Отзывы: