ECOFEL BOILER SERVICE MANUAL
12.1 Programming the Parameters:
To start parameter programming procedure:
a) Turn the R80 potentiometer to Test and R81 potentiometer to Summer modes.
b) Within 2 seconds set R81 to OFF, SUMMER – OFF, SUMMER and finally to any value in winter mode respectively.
c) CR6, CR7 and CR8 leds blink simultaneously for 2 seconds. Parameter adjustment is accessed.
d) Each led represents a parameter. Switching between the parameters (leds) to be programmed with R81 button
is possible. By means of R80 button, the value of the selected parameter can be changed.
• Parameter adjusting shall remain active for 2 minutes. Parameter programming menu can be exited by applying
the access method or by cutting the power of the appliance.
• After the parameter value is changed, the new value will be saved to the card processor in 5 seconds. When
saving is realized, Leds blink for 2 seconds.
- 23 -
Revision Date: 29 February 2008, Rev. No: 0
Parameter
Led
Explanation
Options
Led
P 01CR
6 (Green)
Max. Heating Power
0…100% current range
transmitted to the modula-
tion coil
Lights Steadily
P 02CR
7 (Red)
Time to elapse for the
restart of the boiler shut
down by entering regime
0 / 120 seconds
Blinking = 0 seconds
Steady Lighting = 2 minutes
P 03CR
8 (Green)
Gas Type Selection
Natural gas - LPG
Blinking = Natural gas
Steady Lighting = LPG